high-rate biofilter Articles

  • Biofilters vs Asdorption

    In the last three decades biological technologies have emerged as a sustainable and economically-viable alternative compared to traditional techniques like adsorption/absorption for purifying gases. They were well-received initially in the industry and interesting products with good results were carried out for several years. However, owing to a series of reasons that will be detailed in this ...


    By Bioconservacion SA

  • Longer Life For Biofilters

    Biofilters are the odor control system of choice at composting facilities. Despite similar capital costs, the biofilters are generally less costly to operate than chemical scrubbers. The key to keeping operating costs in check, however, is to get the maximum use out of the biofilter media, thus avoiding the time and money needed to do media replacements. Allen Boyette, senior engineer and manager ...


    By BioCycle Magazine

  • Biofilter Applications in the Coatings Industry

    Soaring energy costs and the high cost of ‘end-of-pipe’ pollution control equipment has caused companies and regulatory agencies to re-evaluate ‘unconventional’ means of achieving VOC and HAP emissions control. The coatings industry is an excellent candidate for alternative, unconventional controls, as VOC and HAP reductions have not been as strident as has been the case in many other industries. ...


  • Biofilter Applications in the Coatings Industry.

    Soaring energy costs and the high cost of ‘end-of-pipe’ pollution control equipment has caused companies and regulatory agencies to re-evaluate ‘unconventional’ means of achieving VOC and HAP emissions control. The coatings industry is an excellent candidate for alternative, unconventional controls, as VOC and HAP reductions have not been as strident as has been the case in many other industries. ...


  • High VOC Loadings in Biofilters - Petroleum and Industrial Applications

    ABSTRACTMore cost effective alternate technologies are needed to meet the demands of existing and upcoming Federal air regulations. Bio-Reaction Industries, Inc. (BRI) has developed a patented, modular, high-rate, vapor-phase biofilter that has provided such a solution for a major oil company for the past four years. This compact system has adsorbed and digested high VOC surge concentrations ...


  • A High Performance Biofilter for Toluene Emission Control

    A high performance biofilter was designed at the Université de Sherbrooke in Québec. This laboratory-scale biofilter was used for the treatment of gas streams polluted with toluene present in low or high concentration. A maximum elimination capacity of 135 g.m -3 .h -1 was achieved, and no clogging of the biofilter was observed during the experimental period. The performance of the cleaning ...


  • Pilot-Scale Biofilter Test for Treating Zimpro Odors

    The thermal sludge conditioning process of U.S. Filter/Zimpro Corporation, Rothschild, Wisconsin (Zimpro process) is primarily used to improve dewatering characteristics of the waste sludge. The process entails a partial breakdown through oxidation and hydrolysis of complex, high molecular weight organic compounds, such as, proteins, fibers, carbohydrates, and fats. The partial breakdown of ...


    By PRD Tech, Inc.

  • Biofilter Removal of VOCs and Toxics from Airborne Emissions

    Abstract Sewage treatment plants can emit significant quantities of volatile organic compounds (VOCs) and toxic air contaminants, but emission control by conventional methods has been difficult to achieve. The biofilter technology developed in a previous contract can satisfactorily control emissions from these plants and possibly from other sources of high-volume, low-concentration emissions ...


  • Performance evaluation of an aerobic biofilter with high organics containing synthetic wastewater

    The organics removal performance of a lab-scale aerobic biofilter of volume 0.6 L was studied using synthetic wastewater and waste automobile tyre-tube beads as media. The column study was performed under Chemical Oxygen Demand (COD) in the range of 500-1500 mg/L at an empty bed contact time (EBCT) of 2 h. The treatability constant at 27°C was found to be 41.963. A maximum COD removal efficiency ...


    By Inderscience Publishers

  • Vapor-Phase Biofilters Show Promise for Treating High VOC Emissions.

    Evaluating the Feasibility of Natural AttenuationUsing natural attenuation to remediate organic compounds in groundwater has gained popularity. In some cases, this process can reduce contaminant levels to below risk-based corrective action criteria or regulatory standards without implementing additional remedial action alternatives. However, it is often difficult to prove that natural ...


  • High VOC Loadings in Biofilters - Petroleum and Industrial Applications (PDF)

    More cost effective alternate technologies are needed to meet the demands of existing and upcoming Federal air regulations. Bio-Reaction Industries, Inc. (BRI) has developed a patented, modular, high-rate, vapor-phase biofilter that has provided such a solution for a major oil company for the past four years. This compact system has adsorbed and digested high VOC surge concentrations (over 90,000 ...


  • High performance of nitrogen and phosphorus removal in an electrolysis-integrated biofilter

    A novel electrolysis-integrated biofilter system was developed in this study to evaluate the intensified removal of nitrogen and phosphorus from contaminated water. Two laboratory-scale biofilter systems were established, one with electrolysis (E-BF) and one without electrolysis (BF) as control. The dynamics of intensified nitrogen and phosphorus removal and the changes of inflow and outflow ...


    By IWA Publishing

  • Vapor-Phase Biofilters Show Promise for Treating High VOC Emissions

    Evaluating the Feasibility of Natural AttenuationUsing natural attenuation to remediate organic compounds in groundwater has gained popularity. In some cases, this process can reduce contaminant levels to below risk-based corrective action criteria or regulatory standards without implementing additional remedial action alternatives. However, it is often difficult to prove that natural ...


  • Comparison of the biological NH3 removal characteristics of a three stage biofilter with a one stage biofilter

    A three stage and a one-stage bench-scale biofilter with effective heights of 129 cm filled with same type of packing material were operated at different influent concentrations of ammonia in order to investigate their performance in treating waste gas streams. The columns contained a mixture of municipal compost inoculated with thickened municipal activated sludge as a base material and shredded ...

  • High Rate Biological Odour Control Demonstration for Biosolids Exhausts

    Abstract Biorem has successfully demonstrated its high rate odour control system for biosolids exhausts at Ashbridges Bay sewage treatment plant in Toronto, Ontario. The demonstration used XLD™, a biofiltration media engineered specifically for biosolids odours. The system has achieved 95% odour removal in less than 20-s Empty Bed Residence Time (EBRT) despite high concentration of ...


    By Biorem Technologies Inc.

  • A Comparison of an Organic Biofilter and an Inorganic Biofilter for the treatment of Residual odors emanating from a Biosolids De-Watering facility

    The following paper is a comparison of an organic media biofilter and a synthetic media biofilter for the treatment of residual odors emanating from the operation of a biosolids dewatering and truck loading system at the City of Toronto's Ashbridges Bay Treatment Plant. The system compared was an in-ground, header/lateral system operated in a forced draft, up flow, open top configuration. The ...


    By Biorem Technologies Inc.

  • High rate Biological odour control system - Case Study

    ABOUT THE PROJECT Biorem has conducted a successful demonstration of high rate odour control at Preston Wastewater Treatment Plant in Cambridge, Ontario over the last three years. The system treats exhausts from primary clarifier and intermediate pump station. A combination of biotrickling filtration (BTF) and biofiltration (BF) processes was used in a novel horizontal flow ...


    By Biorem Technologies Inc.

  • Biotreatment of waste gas containing pyridine in a novel rotating rope biofilter

    A novel Rotating Rope Biofilter (RRB) has been developed especially for the treatment of Volatile Organic Compounds (VOCs) at higher loadings and characterised by high volatility along with high water solubility. The RRB provides a higher interfacial area (per unit reactor liquid volume) along with high oxygen mass transfer rate, greater microbial culture stability, and consequently higher ...


    By Inderscience Publishers

  • Nitrogen removal efficiency and microbial community analysis of ANAMMOX biofilter at ambient temperature

    An upflow anaerobic biofilter (AF) was developed to investigate anaerobic ammonium-oxidizing (ANAMMOX) efficiency in treating low-strength wastewater at ambient temperature (15.3–23.2 °C). Denaturing gradient gel electrophoresis (DGGE) and fluorescence in situ hybridization were used to investigate treatment effects on the microbial community. Stepwise decreases in influent ...


    By IWA Publishing

  • Back-propagation neural network for performance prediction in trickling bed air biofilter

    Experimental studies were carried out with a laboratory-scale biotrickling filter to treat a gaseous stream contaminated with benzene, toluene and xylene (BTX) operated in a continuous mode. The biotrickling filter initially acclimatised with toluene was used to treat BTX compound individually at loading rates ranging from 7.2 g/m³hr to 62.2 g/m³hr, operated in a sequential mode. The results ...


    By Inderscience Publishers

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you