horizontal aerator Articles

  • Performance of Floating Horizontal Aerators in Aerated Lagoons and Oxidation Ditches

    INTRODUCTION When selecting aeration equipment to use for a specific application, issues to address include reliability, serviceability, capital cost, system appurtenances, and cost of operation and maintenance. Another important consideration is oxygen transfer rate (OTR). Horizontal floating aerators have relatively high transfer rates and have been used successfully in aerated lagoons and ...


    By S & N Airoflo, Inc.

  • Floating Horizontal Aerators Enhance Eufaula, Alabama Activated Sludge Plant

    The Eufaula, Alabama, wastewater treatment plant (WWTP) is an extended aeration activated sludge facility designed for an average daily flow rate of 2.7 million gallons per day (mgd). Prior to February, 2005 this WWTP used vertical aerators to provide oxygen and mixing in its aerator basins. The plant has two aeration basins, each 1.87 million gallons in volume, which had 160 horsepower (hp) of ...


    By S & N Airoflo, Inc.

  • Performance evaluation of wastewater treatment using horizontal subsurface flow constructed wetlands optimized by micro-aeration and substrate selection

    The effects of micro-aeration and substrate selection on domestic sewage treatment performance were explored using three pairs (with or without micro-aeration) of horizontal subsurface flow (HSSF) constructed wetlands (CWs) filled with zeolite, ceramsite or quartz granules. The individual and combined effects of micro-aeration and substrate selection on the purification performance of the ...


    By IWA Publishing

  • Case study - Aeration ditch upgrade exceeds expectations

    Triton Process Aerators Meets Future Nitrogen Permit Regulations When the a Pennsylvania Sewer Authority was researching methods to improve the dissolved oxygen levels in its wastewater treatment plant’s oxidation ditches in 2001, they decided to totally replace its aging brush rotor system. They replaced the rotors with the  ...

  • In Situ Local Parameter Measurements for CFD Modeling to Optimize Aeration

    ABSTRACTMeasurement methods to determine in situ local parameters were developed, in order to optimize design and operating parameters impacting oxygen transfer in aeration tanks equipped with EDPM membrane diffusers and slow speed mixers. New tools to measure bubble sizes and gas hold-ups were coupled with the traditional ones used to determine liquid velocities and oxygen transfer coefficients. ...

  • Triton aerator/mixer saves energy & operational costs & reduces carbon footprint

    Municipal and industrial users tackle many wastewater treatment challenges at their facilities including meeting more stringent permit limits with limited or declining resources. The ideal solution for today’s professional is finding an innovative technology that offers a cost-effective, sustainable treatment solution that exemplifies environmental stewardship in the community. Many ...

  • The effect of aerated rock filter geometry on the rate of nitrogen removal from facultative pond effluents

    Rock filters are an established technology for polishing waste stabilization pond effluents. However, they rapidly become anoxic and consequently do not remove ammonium-nitrogen. Horizontal-flow aerated rock filters (HFARF), developed to permit nitrification and hence ammonium-N removal, were compared with a novel vertical-flow aerated rock filter (VFARF). There were no differences in the ...


    By IWA Publishing

  • Computational fluid dynamics simulations of membrane filtration process adapted for water treatment of aerated sewage lagoons

    The aim of this study is to apply the membrane bioreactor technology in an oxidation ditch in submerged conditions. This new wastewater filtration process will benefit rural areas (<5,000 population equivalent) subject to chronic water shortages by reusing this water for irrigation of green areas. For this purpose, the membranes developed without support are immersed in an aeration well ...


    By IWA Publishing

  • Asian dairy churns out grade AA effluent

    ' The AIRE-O2® aerators have excellent oxygen transfer, easy maintenance and operation.' Problem Founded in 1937, this dairy cooperative located in Asia has played a leading role in the development of the industry in its country. Its mission is to 'supply quality products for safe-guarding the nation’s health' in all its product line. The same attention to quality standards that drives ...

  • Helm Plant, Calfornia case study by AEROMIX Systems Inc.

    Client: Hunts/ConAgra Foods Location: Helm Plant, California Type: Domestic & Industrial Wastewater Treatment Facility Hunts/ConAgra Foods, located in Helm, California, processes over 300 tons of tomatoes per hour. It is believed to be one of the biggest plants of its kind. The plant employs an innovative transport system, using a flume ...


    By RWL Water LLC

  • Case study - A new system for Nitrogen removal

    South African wastewater facility saves energy and meets nutrient removal regulations Many small communities across the U.S. and around the globe are struggling to meet more stringent nitrification of ammonia requirements on a tighter budget. When a South African community could not meet its state requirements and struggled with a failing rotor disc system, the town’s officials ...

  • Hess Collection (Winery) WWT Paper

    Winery wastewater treatment at Hess Collection Winery (Napa, CA) features floating horizontal brush aerators, data logging, and computer monitoring and control to simplify required water quality reporting. Since installation in 2001, Hess Collection Winery has never been out of compliance with state discharge limits. Wineries generate a strong organic wastewater that is highly depending on ...


    By S & N Airoflo, Inc.

  • Mixers and Flowmakers: Flowmakers at the Lynetten WWTP, Copenhagen

    In 1995 Landia installed 95 flowmakers, type POPL-I, in the aeration tanks at the Lynetten Wastewater Treatment Plant in Copenhagen. The wastewater treatment plants Lynetten and Damhusåen to which Landia also supplied mixers treat a total of 75-100 mio m³ wastewater a year - approx. 1.1 mio. person equivalents. The Lynetten WWTP is the largest wastewater treatment plant in Denmark. The client ...


    By Landia

  • Case study - Deep ditch minimizes footprint

    Aerator/mixer system reduces effluent discharge BOD, TSS and phosphorus A goal of many communities in planning wastewater treatment facilities is to minimize the footprint, reducing land use. To reach this goal, a Chinese municipality built their oxidation ...

  • Enhancing the Performance of Oxidation Ditches

    ABSTRACT Oxidation ditches are very popular wastewater treatment processes for small to mediumsized municipalities that have to meet stringent water quality standards. Oxidation ditches provide cost-effective treatment while requiring relatively simple operational skills. Because carbonaceous BOD removal, nitrification, and de-nitrification can be accomplished within a single reactor, the ...


    By S & N Airoflo, Inc.

  • Triton solves bulk of the problem case study

    The Dubai Investments Park (DIP) wastewater treatment plant (WWTP) is located about 20 miles south of the Burj Khalifa – the world’s tallest building. The oxidation ditch activated sludge plant recently found itself strained by filamentous sludge bulking likely caused by high organic loads, high summer temperatures and inevitable low dissolved oxygen. The problem was easily ...

  • Aire-O2 Triton Solves Bulking Problem

    The Dubai Investments Park (DIP) wastewater treatment plant (WWTP) is located about 20 miles south of the Burj Khalifa – the world’s tallest building. The oxidation ditch activated sludge plant recently found itself strained by filamentous sludge bulking likely caused by high organic loads, high summer temperatures and inevitable low dissolved ...

  • Sustainable, Low-maintenance Disinfection for Onsite Systems

    Most of the regulations applicable for onsite wastewater treatment system are based on the use of native soil for effluent dispersal. However, there are more and more situations where dispersal of effluent in native soil is impossible: repairs of existing systems on undersized lots for implementation of required dispersal fields: sites located in soils having low permeability: or where the ...


    By Premier Tech Aqua

  • Case study - DO control maximizes oxidation ditch treatment efficiency

    Process control is key to maximizing wastewater treatment efficiency while minimizing operating costs. Implementing the right process control system in conjunction with the right equipment can save money on electrical costs and equipment maintenance. The wastewater plant for the city of Dawson, MN, uses a  ...

  • Hydraulic model comparison of vertical-flow regimes in constructed wetlands

    Vertical-flow treatment wetlands have come into use because of their ability to provide highlevel secondary and tertiary wastewater treatment at a fraction of the land use of horizontal subsurface flow or free water surface wetlands. The flow regime typically selected is vertically downward, allowing wastewater to infiltrate through the system by gravity. However, recent research suggests that ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you