hydrogen sulfide micro-sensor Articles

  • Developing Technologies to Detect Hydrogen Sulfide (H2S) Gas

    Abstract Hydrogen sulfi de (H2S) gas can cause nausea, headaches, unconsciousness, and death. Industries struggle to detect this deadly substance before it harms workers or communities. Safety system manufacturers have developed detectors that sense the H2S quickly and accurately. This paper illustrates, in general terms, considerations in effective placement of H2S detectors: ...

  • State of the art treatment for Arsenic, color, and Hydrogen Sulfide - Case Study

    New Arsenic Regulations How meaningful to the average water customer are µg/l or parts per billion? Not very. How about the word “arsenic”? That will ring some bells as the mystery novel poison-of-choice. But with new, lower EPA arsenic standard of 10 ppb that went into effect Jan. 16, cities with ...


    By Filtronics, Inc.

  • A sewer process model as planning and management tool – hydrogen sulfide simulation at catchment scale

    The collection system of a major city at the Persian Gulf was simulated for bulk water hydrogen sulfide and the release of sewer gas to the urban atmosphere. Geometry data on 870 km of sanitary sewer and data on dry weather flow entering all nodes in the catchment was exported from a Mike Urban database and imported to the sewer process model WATS. The process model then routed sewage and sewer ...


    By IWA Publishing

  • Two Detector Solution to Analyzing Sulfur

    Sulfur compounds are reactive, corrosive to pipes, and destructive to catalysts in petroleum refineries. Sulfur emission are strictly regulated globally. When released into the atmosphere sulfur dioxide converts to sulfuric acid resulting in adverse effects on human health and the environment. Sulfur detection is found useful in many other industries; therefore, detection of sulfur compounds in ...


    By Restek Corporation

  • Micro-aeration for sulfide removal in anaerobic treatment of high-solid wastewater: a pilot-scale study

    The presence of sulfur compounds (e.g. protein, sulfate, thiosulfate, sulfite, etc.) in the feed stream generates highly corrosive and odorous hydrogen sulfide during anaerobic digestion. The high sulfide level in the biogas stream is not only poisonous to many novel metal catalysts employed in thermo-catalytic processes; but also reduces the quality of methane as a renewable energy. This study ...

  • Electrochemical Sensors for Specific Gas PPM Monitoring

    Echem sensors are able to read a specific gas even when it is mixed in a background of other gases. Echem sensors are typically used to read very low PPM concentrations of toxic gases. The Echem sensor consists of a small cell holding an electrolytic solution. This solution needs a specific gas in order to produce an electrical signal. When the specific gas passes through a permeable membrane and ...

  • Lake Josephine Community, Florida - Case Study

    In January 2010, AdEdge Water Technologies, LLC was contacted by Aqua Utilities Florida to provide a hydrogen sulfide removal system for the Lake Josephine Community located in Highlands County, Florida. The existing water system consisted of two wells feeding into a centralized distribution system with a maximum capacity of 230 gpm being consumed by a population of 1,250 persons. The raw water ...

  • Continuous emission monitoring and control of packed tower odor control systems using the sycamore CEM

    ABSTRACT Packed-tower chemical scrubbers, with sodium hydroxide (caustic) and sodium hypochlorite (bleach), are commonly used to treat foul air from wastewater treatment processes. The available control mechanisms include a pH probe and controller for the sodium hydroxide feed, an oxidation reduction potential (ORP) probe with a controller toestablish the bleach feed, and proprietary ...

  • Anaerobic digestion of waste biomass from the production of L-cystine in suspended-growth bioreactors

    Waste biomass from the industrial production of the amino acid L-cystine contains above-average concentrations of organic pollutants and significant concentrations of nitrogen and sulfur. The specific biogas production (SBP) of waste biomass was monitored in parallel suspended-growth laboratory anaerobic bioreactors. After severe inhibition was observed, three different procedures were applied ...


    By IWA Publishing

  • Taming Taste & Odor (T&O) Problems - Case Study

    Some taste and odors are caused by mineral constituents in the water, e.g. excess chlorine and hydrogen sulfide. However the majority of taste and odor are the result of biologic activity. Spring turnover of lakes and algal blooms are responsible for Blue-green algae (Cyanobacterium), Green algae and diatoms that introduce filter clogging organisms that also foul anion exchange resins, degrade ...


    By Jenfitch, LLC

  • Follow toxic gas standards for a smoother project

    Toxic gases, such as Hydrogen Sulfide and Sulfur Dioxide, can injure and kill quickly. Therefore, mitigation of these hazards must be fast and sure. The United States Occupational Safety and Health Administration (OSHA) and other authorities take detection of these gases very seriously. The American National Standards Institute/ American Petroleum Institute (ANSI/API) and ISA industry standards ...

  • Environmentally Friendly Elimination of the World`s Contaminants

    About UltraZymeUltraZyme is a highly concentrated, proprietary blend of selected natural micro-organisms, essential nutrients, and synergists which help degrade the high concentrations of fat, grease, oil, blood, floating matter, and organic matter found in processing wastes from a number of sources. Possible applications include meat plants, (poultry, fish, beef, pork, etc.) oil spills, ...


    By Cypher Environmental Ltd.

  • Wastewater force main management – internal corrosion survey using inline methods

    In our first post about Wastewater Force Main Management, we looked at how preliminary analysis helps operators develop a plan for managing their system. After completing this process, operators can begin putting the plan into action with preliminary surveys on specific force mains. For those at WEFTEC, you can visit Pure ...


    By Pure Technologies

  • City of Roswell, Georgia - Case Study

    In late 2011, the United States Army Corps of Engineers (USACE) approved plans to install a new well and build a new water treatment facility for the City of Roswell, Georgia. Barlovento LLC was selected during a competitive bidding process to provide an iron and manganese removal system for the new water supply. AdEdge Water Technologies, LLC was contracted to design, manufacture, and commission ...

  • Wastewater Force Main Management – Internal Corrosion Survey using inline methods

    In our first post about Wastewater Force Main Management, we looked at how preliminary analysis helps operators develop a plan for managing their system. After completing this process, operators can begin putting the plan into action with preliminary surveys on specific force mains. For those at WEFTEC, you can visit Pure ...


    By Pure Technologies

  • Model 5100 Verification/Validation case study

    Background Many sensors used in gas analyzer systems come into direct contact with the process gas, and there is the potential for degradation over time especially with streams that contain contaminants like glycol, moderate to high levels of hydrogen sulfide etc. With sensor degradation, the analyzer response characteristics change resulting in inaccurate readings. In order to ...

  • Assessing Feasibility of Direct Drive Technology for Energy Recovery from Digester Biogas

    ABSTRACTThe Regional Municipality of Waterloo completed a study, with support from Environment Canada, to evaluate the feasibility of using direct drive technology to recover energy from digester biogas. The study identified that a 150 HP engine, operating at 54 % load, could be supported by the estimated gas production of 1560 m3/d with 63 % methane by volume. ...

  • Case study - Shopping center avoids litigation by resolving sewer odor problems

    Mazzei Injector Company, LLC is a recognized industry leader in gas to liquid mass transfer primarily from its proven 25 year experience with ozone applications. In addition, Mazzei has installed the same patented Venturi injector and mixing nozzle technology in many municipal and industrial wastewater systems in applications at lift stations, equalization tanks, aeration basins, activated sludge ...

  • Fixed Versus Portable Gas Detection – Which Is Better?

    Did you know that workers are needlessly injured every year as a result of leaking toxic or combustible substances? Such incidents are known to involve a wide range of hazardous gases (including ammonia, carbon monoxide, chlorine, hydrogen sulfide, hydrocarbon vapors and so on). The sad reality is that most of these accidents are avoidable if only the workplace is adequately monitored. This leads ...

  • Enhanced Bioremediation

    Introduction Enhanced bioremediation is a process in which indigenous or inoculated micro-organisms (e.g., fungi, bacteria, and other microbes) degrade (metabolize) organic contaminants found in soil and/or ground water, converting them to innocuous end products. Nutrients, oxygen, or other amendments may be used to enhance bioremediation and contaminant desorption from subsurface materials. ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you