  • Enumeration of sulphate-reducing bacteria for assessing potential for hydrogen sulphide production in urban drainage systems

    Urban drainage structures have increasing demands which can lead to increasing hydrogen sulphide related problems forming in places where they have not previously been prevalent. This puts pressure on the methods currently used to monitor and diagnose these problems and more sophisticated methods may be needed for identifying the origin of the problems. Molecular microbiological techniques, ...


    By IWA Publishing

  • Monitoring And Analysis of Landfill Gases

    CoGDEM is the trade association representing manufacturers and service providers who are active in the field of gas detection instrumentation and environmental monitoring apparatus. Crowcon Detection Instruments Ltd was one of the founding members of CoGDEM, and in this article their Product Manager of Fixed Systems, Andy Avenell, gives an update on Landfill Gas. Landfill is by far the most ...

  • Case study - Monitoring landfill gas

    Infrared absorption Infrared absorption is usually the preferred method for measuring methane and carbon dioxide. Most gases absorb radiation in the infrared region. The wavelength of radiation that is absorbed is determined by the natural vibration frequencies of the molecule. These natural frequencies will depend on several factors. Thus different gas molecules have different natural ...

  • The latest ground Gas monitoring innovations

    The latest Ground Gas monitoring innovations   The traditional methodology for ground gas monitoring has been ‘spot monitoring’ – taking event readings at various set times to predict the sub surface gas regime on both on Brownfield and Landfill sites.     This methodology is in general current practice under both the EU Landfill Directive ...


    By Shawcity Limited

  • Continuous AD monitoring for McCain`s CHP case study

    Application Anaerobic digestion Equipment AEMS Location Whittlesey, United Kingdom Customer McCain Foods Requirement McCain Foods corporate affairs director, Bill Bartlett said, “The Geotech static gas analyser is here to analyse gas quality as it is ...

  • Case study - Monitoring sewage sludge AD for Southern Water

    To check sludge AD, Southern Water uses portable biogas analysers specially developed for AD biogas and based on proven methane and associated gas analysis equipment from Geotech. Southern Water has an important routine; every single day it checks the health of its sewage sludge anaerobic digesters on eighteen sites across Hampshire, IoW, Sussex and Kent. There, each day Southern Water ...

  • No more odor and corrosion case study

    Sewer systems are vulnerable to corrosion and, at times, can be the source of unpleasant odors. Kemira’s new H2S-Guard tackles both problems, as in most cases the source of these issues is hydrogen sulphide, forming in septic areas, in other words areas where no oxygen for metabolic reactions is available. The H2S-solution combines three important steps: measurement, monitoring and control ...

  • Roof over primary settling tanks to prevent air pollution and odours

    The Wastewater Purification Plant (EDAR) in Cambrils, Tarragona, was the setting for a solution deployed by Bioconservación, a gas absorption and air purification specialist. The project involved covering over the settling tanks to prevent hydrogen sulphide dissolved in the water from polluting the surrounding air. The H2S (hydrogen sulphide) dissolved in water as it arrives at the tank in ...


    By Bioconservacion SA

  • Case study - React Environmental use GA3000 to measure methane

    About the customer React Environmental anaerobic digestion plant in Carmarthenshire, Wales, handles up to 5,000 tonnes of food waste a year. The Geotech product The company uses Geotech's GA3000 (now superseded by GA3000 PLUS) fixed biogas analyser to monitor methane, carbon dioxide, oxygen and hydrogen sulphide.  React's Arrash Shirani talks about ...

  • A Four Channel Gas Detector for Wastewater Treatment Plants

    Common hazardous gases found in wastewater treatment plant facilities are hydrogen sulphide, methane, ammonia, carbon monoxide, chlorine and oxygen deficiency. Some facilities may also use ozone, chlorine dioxide or sodium hypochlorite with the chlorine during the sanitization treatment process. Furthermore, sulphur dioxide is often used to de-chlorinate the water once the treatment process is ...

  • Detecting Gases: What You Can`t Smell Can Hurt You

    Walking through a drill-site area, a worker smells rotten eggs and stops tor a minute or two to assess where a gas leak might exist. Rubbing his itchv eves as he investigates further, he notices that he no longer smells the tell¬tale hydrogen sulphide odour. He does not realize that the gas has deadened his olfactory senses and unless he leaves the area within seconds, he could lose ...

  • AEMS signals methane concentration for Landfill Systems case study

    Application Landfill - power generation Equipment AEMS and GA3000 Location United Kingdom Customer Landfill Systems Requirement Landfill Systems needed a fixed gas analyser with telemtery for landfill gas power generation. ...

  • Noses for Surveillance of Wastewater from Secondary Treatment Plants in Alexandria, Egypt

    Intermittent discharges of industrial chemical pollutants into sewers can have a damaging effect on the processes involved in treating wastewater. They are sometimes able to pass through treatment plants and enter into the receiving water, to exert a harmful effect on the environment and possibly pass down a river to the intakes forwater supplies. We evaluated the use of an electronic ...


    By PCA Technologies SRL

  • Gas Safety in Confined Spaces

    Introduction An offshore worker ensures a vessel is safe to enter; a plant manager enters a small plant room; a contractor inspects the lining of a sewage pipe.  All these personnel face common dangers, despite working in widely different industries.  Gas-related injury poses a serious threat in any confined space where the free movement of air is limited. A confined space ...

  • Measuring methane at the UK`s first viable compact anaerobic digester plant

    At the UK's first viable compact anaerobic digester (AD) plant aimed at local food waste treatment, a Geotech GA3000 fixed biogas analyser monitors methane (CH4), carbon dioxide (CO2), oxygen (O2) and hydrogen sulphide (H2S). The plant, a modular scalable AD system, unveiled by React Environmental in July 2012 at Llangadog, Carmarthenshire, can handle some 1,000 ...

  • Silent sentinel role for static gas analyser at United Utilities

    Biogas produced by the United Utilities anaerobic digestion sludge plant at Lancaster (Stodday) waste water-treatment runs a brand new 525kW combined heat and power (CHP) engine generating electricity and now operating 24/7. It joins an existing 325kW engine already in service for three years. In addition to biogas from the Stodday mesophilic anaerobic digester, a new enzymic hydrolyser increases ...

  • Case study - Geotech’s first GA5000 landfill gas analyser takes 100,000 readings for SUEZ environnement

    Geotech’s first GA5000 analyser, manufactured three years ago, was recently spotted in the company’s calibration rig.  This portable landfill gas monitor was the first production unit of the newly launched GA5000 gas analyser range and has prompted Geotech to look into the analyser’s life since then. The analyser was on its sixth service since manufacture, under ...

  • Machining Coolant Recycling: Unidrive

     Unidrive Pty Ltd undertake extensive machining operations during the production of automotive components. In the past this resulted in the generation of 20,000 litres of waste coolant every week. By implementing a coolant recovery and recycling system, Unidrive have saved approximately $179,000 per annum as a result of more efficient coolant usage and management. ...


  • Ensuring personnel safety in a confined space

    “There are no second chances with a confined space entry. It has to be right first time.“ Identifying a confined space… The HSE Confined Space Regulations 1997 define a confined space as: “A space of an enclosed nature where there is a risk of death or serious injury from hazardous substances or dangerous conditions” Some confined ...


    By a1-cbiss

  • Case study - Safety, Protection against corrosion and cabinet pressurisation in refineries

    The environment in a refinery is highly corrosive. This makes it necessary to deploy control systems not only to protect staff but also to protect the equipment controlling the processes, in order to ensure their reliability. Bioconservacion has equipment that is specially designed for the safety of staff, and for protecting against corrosion in control rooms and cabinet pressurisation equipment. ...