incineration filter Articles

  • Waste Incinerator Project

      Medical Waste Incinerator YD Model is our classic product for market. All series included burning capacity 10kgs per hour, 30kgs per hour,50kgs per hour,100kgs per hour,150kgs per hour,300kgs per hour,500kgs per hour. Up to now, all models sale to all over the world and have good feedback from end-customer. The YD Model medical incinerator have multi-combustion chamber and basic dry ...


  • Minicipal Waste Incinerator Case History

    Low temperature plant operation had resulted in severe baghouse corrosion and constant dust blockages throughout the system. It was decided to raise the operational temperature of the incinerator and change the acid gas scrubbing agent from lime to sodium bicarbonate. However, the existing felt filter media could not cope with the change in acid gas scrubbing agent and “blinded” very rapidly ...


    By W. L. Gore & Associates

  • Case study - Municipal Incinerator (Slovenia)

    WID and BREF-compliant EU showcase municipal incinerator in Slovenia During 2008 Glosfume was asked to supply a ceramic filter which could achieve emission levels below WID. Representing the state-of-the-art in high temperature filtration design rated at 70,589 Am3/hr @ 250 °C. The installation complies both Waste Incineration Directive (WID) and BAT Reference note ...


    By Glosfume

  • Case study - OTMS Boxed Beef Incinerator (UK)

    Over Thirty Month Scheme (OTMS) 'Boxed Beef' incinerator. This installation involved replacement of a 3-metre ceramic element filter that suffered constant element breakages and inadequate SO2 removal due to a poorly designed filter and powder injection system. The client appointed W.S. Atkins to source a filter which had high efficiency particulate removal and effective dry ...


    By Glosfume

  • Case study - HMS Ocean Waste Incinerator

    Ship's Waste Incinerator This installation is Glosfume's first filter to be used at sea. Stringent laws prevent ships from dumping waste at sea, all waste has to be returned to its point of origin. The Royal Navy is one of the first to install an incinerator and filter onboard a ship. Extensive testing was carried out before fitting the unit to HMS Ocean; installation involved cutting a ...


    By Glosfume

  • Case study - Nuclear Waste Incineration (France)

    Nuclear waste incineration trials 1996 Glosfume successfully provided a pilot filter to carry out various trials on nuclear waste incineration. The filter was designed to operate under vacuum and passed all of the stringent requirements of French Nuclear Fuels. Similar filters have subsequently been used on several sites throughout France, contributing to reduced waste disposal costs and ...


    By Glosfume

  • Optimizing Baghouse Performance in Waste-to- Energy Incinerator

    An end user with many years experience, operating3 different Municipal Waste Incineration plants, decided to build a new “state of the art” plant. After fully investigating the performance of different types of filter media, he decided upon GORE-TEX® membrane on GORE-TEX® felt, as he was convinced that is was the “best available ...


    By W. L. Gore & Associates

  • Case study - WID-compliant Wessex Incineration (UK)

    This installation was Glosfume's first use of a new process designed to incorporate an innovative 'radiant heating tube' which allows fumes to cool prior to filter without the need for dilution air and/or a heat exchanger. This design has subsequently been successfully utilised on several similar rotary incinerator installations. The plant was the first to comply with strict Waste Incineration ...


    By Glosfume

  • Rotary Kiln Incineration Plant - Case Study

    The R1200 plant was installed in the early 00’s in Macau. The fully integrated system boasts a burn rate if 1200kg per hour and accepts a variety of different waste streams that include, clinical waste, pharmaceutical waste, liquid waste that includes solvents, waste oil, shredded tyres and well as some livestock as large as horses. The rotary kilns incineration principle is defined by one ...

  • Mayo finds technical fix to reduce incinerator emissions

    While the medical waste incinerator at Mayo Clinic in Rochester, Minn., consistently met state and federal emission requirements, facility leaders wanted to find a way to go beyond these standards. Mayo Clinic’s medical waste incinerator serves Mayo Clinic, Saint Marys Hospital and Rochester Methodist Hospital, which form the largest group medical practice in the world, and processes 2,000 ...


    By Bionomic Industries Inc.

  • A STIEFEL project Waste Incineration Plant (KVA) Trimmis case study

    The waste incineration plant (KVA) Trimmis is situated in the eastern part of Switzerland and is connected to the railway network. As it is the only incineration plant in this province, it serves a large area with approximately 131’000 inhabitants. The local authorities waste disposal association named GEVAG is a public body serving 43 convention communities and 97 associated municipalities ...


    By Jakob Stiefel GmbH

  • Recycling Vs. Landfills and Incinerators – Do Benefits of One Outweigh the Other?

    Believing the 2011 survey results of the U.S Environmental Protection Agency (EPA), the American nationals generate more than 240 million tons of waste every year. Often referred to as Municipal Solid Waste, this waste originates from households, schools, hospitals, and business establishments. This trash material often finds its place in the wasteland, where it is either recycled, trapped in a ...


    By Compactor Management Company

  • What are filter aids?

    Filter Aids” is a group of inert materials that can be used in filtration pretreatment. There are two objectives related to the addition of filter aids. One is to form a layer of second medium which protects the basic medium of the system. This is commonly referred to as “precoat”. The second objective of filter aids is to improve the flow rate by decreasing cake compressibility ...

  • Filter technology to meet evolving regulations

    Maguin has developed the Cercat filter for high temperature air pollution control. In this article, David Gambier and Hélène Real outline the technology, as well as installations planned for 2009. Maguin has been present in the waste thermal treatment field since the 1970s. The company’s knowledge has been built through the turnkey supply of thermal treatment units for different kinds of products ...

  • Solid / gas separation with fabric filters

    A myriad of filter media are utilized today for separation of particulate matter in industrial gas filtration applications. These media range from single use (deposable) to semi-permanent media and include fiber, fabric, ceramic, membrane, metal mesh, and sintered metal media. Semi-permanent media are usually cleanable, either on or off-line, and are primarily intended for long-term (up to ...

  • OTM 17: Determination of Metal Concentrations Using Filters and Solid Sorbents in XRF Analyisis case study

    Eli Lilly and Company (Lilly) operates a waste incineration system located at the Tippecanoe Laboratories in Lafayette, Indiana. This incinerator system includes an Xact multi-metals continuous emissions monitoring system (Xact-CEMS, manufactured by Cooper Environmental Services, LLC) for demonstrating attainment with the Hazardous Waste Combustor MACT for semi-volatile metals, low-volatile ...

  • Metropolitan Sewer District (MSD), Cincinnati, Ohio U.S.A.: HTFB System

    The Metropolitan Sewer District (MSD) of Greater Cincinnati, Ohio is a 90 mgd primary treatment, 55 mgd activated sludge treatment plant. Solids processing includes gravity thickening of primary sludge, dissolved air flotation, thickening of secondary sludge, holding tank storage, belt filter press dewatering and pumping of cake to the old outdated multiple hearth ...

  • X-Ray Fluorescence-Based Multi-Metal Continuous Emission Monitor

    ABSTRACT: Army demilitarization incinerators will need to comply with the Hazardous Waste Combustor National Emission Standard for Hazardous Air Pollutants that will regulate metals and metal compounds listed under the Clean Air Act Amendments. A large problem for these incinerator operations is limited knowledge of the type and quantity of emitted metals, so that compliance may be determined ...

  • Wastewater Treatment Plant MSD of Buncombe County, NC

    The Metropolitan Sewerage District of Buncombe County was faced with high maintenance cost of existing equipment, poor reliability and increased incinerator cost. After extension research into dewatering options, it was determined that the most economical dewatering system was on-site dewatering with a belt filter press. BDP was the press of choice due to the 3DPTM belt filter press superior ...


    By BDP Industries

  • Separation and recovery of oil from oily waste materials using anaerobic thermal desrotpion unit technology

    RLC Technologies, Inc.’s Anaerobic Thermal Desorption Unit (ATDU) is an exsitu, non-incineration technology designed to separate hydrocarbons from various matrices including oilfield waste, soil, sludge, sand, filter-cake, tank and tanker bottoms, organic-based hazardous waste and contaminated soil in a non-oxidizing atmosphere without destroying the hydrocarbons. This paper briefly ...


    By RLC Technologies, Inc.

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you