incineration system Articles

  • Incineration

    Introduction: High temperatures, 870 to 1,200 °C (1,400 to 2,200 °F), are used to volatilize and combust (in the presence of oxygen) halogenated and other refractory organics in hazardous wastes. Often auxiliary fuels are employed to initiate and sustain combustion. The destruction and removal efficiency (DRE) for properly operated incinerators exceeds the 99.99% requirement for hazardous waste ...

  • Introducing LaserGas III SP CO – a combustion analyzer for rough environments

    NEO Monitors unveils the industry’s most compact CO combustion analyzer suitable for the most demanding environments. LaserGas III CO includes measurement of CH4, H2O and temperature in one single unit designed to reduce risk. Based on decades of experience and customer feedback, NEO Monitors has designed an Ex-d certified tunable diode laser (TDLS) analyzer. The instrument is ...


    By NEO Monitors AS

  • Increase in capacity of an incinerator

    In addition to its own and external products, system providers involved in the project business also provide process knowledge and complete projects refined to the last detail. The standard is high. Their own knowledge combined with the supplier’s knowledge leads to a complete solution. From the delivery of the components to their installation, trial operation and commissioning, all the ...


    By sera GmbH

  • Power Case Study - North Incinerator

    North Incinerator Finds Solution to Excessive Sweep Elbow Wear At Montgomery County's North Incinerator plant, there was a problem several years ago. The Dayton, OH, area trash-to-energy plant was experiencing repeated shutdowns due to sweep elbow failure in its dense phase pneumatic conveying system, a component of the lime injection system in operation there. In order to ...


    By HammerTek Corporation

  • Incinerator Plant, Lidköping - Case Study

    SWEDEN: Baling of MSW In Lidköping the incineration plant is connected to the central heating systems of the city. However, incineration plants has a high demand for fuel in the winter season and limited demand in the summertime. Inflow of material, however, comes evenly all year around and this gives a need to store waste during the summer. The solution to this is the ...


    By Flexus Balasystem AB

  • Incineration Industry: Scrubber on Sludge Incinerator Reduces Atmospheric Emissions Case Study

    Aberdeen Sewage Treatment Plant in Aberdeen, Washington started up their new Electric Infrared Incinerator in May, 1981. The sewage sludge incinerator, product of Shirco, Inc., needed a pollution control device in order to meet state, local and federal requirements for atmospheric emissions, according to the emissions test on the unit performed January, 1982. Chosen was a Model 24×24- ...


    By CR Clean Air Group, LLC

  • Minicipal Waste Incinerator Case History

    Low temperature plant operation had resulted in severe baghouse corrosion and constant dust blockages throughout the system. It was decided to raise the operational temperature of the incinerator and change the acid gas scrubbing agent from lime to sodium bicarbonate. However, the existing felt filter media could not cope with the change in acid gas scrubbing agent and “blinded” very rapidly ...


    By W. L. Gore & Associates

  • Atmospheric impact of a municipal wastes incinerator

    This paper presents a case study of an air pollution dispersion model for the atmospheric impact assessment of a new municipal wastes incinerator (MWI). The capacity of the present MWI will increase more than ten times, and a new high-efficiency flue gas treatment system is projected. The environmental impact study has been focused on the long-term aspect of the air pollution (chronic pollution) ...


    By Inderscience Publishers

  • Pollutant emissions from modern incinerators

    Emissions of dioxins are mainly from incinerators, domestic and industrial coal combustion, and traffic. However, the major public concern and research effort are associated with the emissions of organic micropollutants from waste incinerators. This paper gives a brief overview of the more recent research and development for the removal of dioxins and heavy metals from flue-gas streams. Special ...


    By Inderscience Publishers

  • A Comparison of Fluid Bed and Multiple Hearth Biosolids Incineration

    Abstract Incineration has been used as a disposal method for wastewater treatment biosolids for over sixty years. The first multiple hearth furnace for biosolids incineration was built in 1935 in Dearborn, MI. From that time through the late sixties, the multiple hearth was the thermal technique of choice for biosolids disposal. Today there are still some 150-175 aging multiple hearths in ...

  • Waste Incineration Upgrades at the Eastman Chemical Company

    INTRODUCTION Eastman Chemical Company, headquartered n Kingsport, TN, is an international supplier of organc chemicals, fibers anci plastics with annual sales of approximately $46 biNion and approximately 5300 customers worldwide. Tennessee Eastman Division, also located in Kingsport, is the company’s largest manufacturing fadllity The nine hundred acre site contains manutacturing facilities as ...


  • Incineration of hazardous wastes from the petroleum industry in Nigeria

    Persistent hazardous wastes are produced in the recovery, processing and upgrading of crude petroleum in Nigeria. However, recent developments in environmental pollution control are drawing increasing attention to the problems of hazardous wastes. The ever-increasing need to control these wastes from the petroleum industry often compels the chemical engineer to specify methods of treatment and ...


    By Inderscience Publishers

  • Power case study - North Incinerator - Environmental

    Subject Montgomery County's North Incinerator plant, in Dayton, Ohio Situation To meet EPA air pollution control standards for sulfur dioxide emissions, finely powdered limestone needed to be injected into the three incineration units at all times. The operation required approximately 18,000 pounds of powdered limestone a day, and needed to be ...


    By HammerTek Corporation

  • UK Abattoir – Rotary incinerator - Case Study

    Designed to process animal remains 24 hours/day, 7 days/week, with the minimum of operator attendance. To optimise the plant’s performance and to enable waste to be processed and stored, irrespective of the status of the combustion plant, the waste is crushed into 50mm cubes. The material is then conveyed into a buffer hopper, which stores sufficient material to enable the plant to be left ...


    By Todaysure Limited

  • Mayo finds technical fix to reduce incinerator emissions

    While the medical waste incinerator at Mayo Clinic in Rochester, Minn., consistently met state and federal emission requirements, facility leaders wanted to find a way to go beyond these standards. Mayo Clinic’s medical waste incinerator serves Mayo Clinic, Saint Marys Hospital and Rochester Methodist Hospital, which form the largest group medical practice in the world, and processes 2,000 ...


    By Bionomic Industries Inc.

  • Optimizing The Operation And Material Selection For Fluorinated Waste Gas Incineration

    A thermal oxidizer system is used by Honeywell Specialty Chemicals to reduce organic and acid gas emissions from their fluoro-products plant. The thermal oxidizer system consists of a multi-gas fired vortex burner mounted on a vertical residence chamber. ...

  • QinetiQ – Modular EU Compliant incineration package - Case Study

    TodaySure™ were commissioned to construct an Integrated Battlefield Support System Incinerator as part of a Ministry of Defence funded research programme, to demonstrate that waste management can be achieved in a responsible way, compliant with challenging environmental standards. Designed to meet the stringent requirements of the EU Waste Incineration Directive, the combustion chambers, ...


    By Todaysure Limited

  • Minimization of Major Air Pollutants from Sewage Sludge Fluid Bed Incinerators

    ABSTRACT Emissions of major air pollutants including carbon monoxide (CO), nitrogen oxides (NOx) and mercury (Hg) were studied at two sewage sludge fluidized bed combustion (FBC) plants. Both the North West Bergen (NWB) County Utility Authority and the Little Miami (LM) plants have air pollution control systems (APCS) that are of the wet type. Various operating conditions such as temperature, ...

  • Incinerator ops do slow burn over proposed EPA guidelines

    Hospitals and health care facilities are keeping a wary eye on the U.S. Environmental Protection Agency, awaiting the latest word on the agency’s efforts to regulate the incineration of medical wastes. Under the pending guidelines, some predict that many of the nation’s remaining 57 medical waste incinerators will be unable to meet the costs or the technological challenges of retrofitting their ...

  • Design And Operational Considerations For Chloro-Fluorinated Liquid And Gaseous Waste Incinerators

    Unlike the thermal oxidation of straight chlorinated waste compounds, the incineration of CFC's and other fluorinated compounds present their own unique incineration requirements. By taking these special characteristics into consideration, a reliable incineration system can be tailored to end-user ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you