infrared analyzer Articles

  • Using FTIR spectroscopy to measure hydrocarbon pollution in water

    According to the World Health Organization (WHO) and UNICEF’s 2015 Progress on Sanitation and Drinking Water report almost 700 million people around the world don’t have access to clean drinking water [1]. Poor water quality is beginning to return to the developed world too. The strain of population growth, intensified agricultural practices and continued industrial expansion have are ...


    By Specac Limited

  • Simplified biofuels measurements with portable mid infrared analyzers

    Product quality begins at the production facility and extends to consumer filling station. Some process control or quality verification analyses can be done with quick and simple verification tests while others require more complete tests according to the ASTM or EN approved methods. Many crucial measurements can be performed by mid-infrared (IR) analysis. These measurements include free fatty ...


    By Spectro Scientific

  • A quick guide to oil analysis for engine test applications

    Reliability testing is a very important component of new engine development. Engineers need to fully understand and chart the engine lifetime performance under a variety of conditions before mass production may be considered. Many important performance data parameters are collected in real time through the many different types of sensors that are connected to the engine in the test cell and oil ...


    By Spectro Scientific

  • Comply with Highly Regulated Oil in Water Measurements Using Portable Infrared Analyzers

    The Petroleum Industry – both offshore and onshore -- has regulations that limit the amount of oil in discharged water.  Fixed filter infrared (IR) analyzers have been used to test oil levels in produced water on drilling platforms for over 45 years for a number of reasons. On oil rigs where real estate is at a premium, infrared analyzers such as the Wilks InfraCal TOG/TPH ...


    By Spectro Scientific

  • Mid-infrared analysis of biodiesel

    The biodiesel industry is growing rapidly. and so is the need for analysis 10 ensure quality product and keep biodiesel in good standing. Biodiesellhat has residual glycerin, glycer· ides, or inorganic salts from the production process can cause problems such as Iilter plugging and injector coking in a diesel engine. The biodiesel blend ralio also can affect cold weather performance, lax ...


    By Spectro Scientific

  • The Effect of Biodiesel Feedstocks on Infrared Blend Measurements

    This White Paper addresses the common concern among biodiesel blenders and distributors as to whether or not biodiesel made from different feedstocks such as soy, waste vegetable oil or palm oil will affect the blend measurement.  The data presented, as well as the chemistry, shows that infrared measurements offer a reliable analytical technique for checking biodiesel blend. Portable ...


    By Spectro Scientific

  • Portable Infrared Analyzers Provide On-Site Measurement of Oil and Grease Levels in Hydraulic Fracturing Water

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well.  Whether the water is going to be taken off-site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the water.  Waiting for remote laboratory results to determine the oil level can take several ...


    By Spectro Scientific

  • Comparing TGA, FTIR and fixed filter infrared analyzers for measuring soot levels in in-service lubricants

    Measuring soot in diesel engine oil has become more important as soot levels get higher due to exhaust gas recirculation. As soot isone of the key indicators for the condition of the oil, diesel engine maintenance programs performing regular soot checks can realize cost savings by extending drain periods and reducing used oil disposal. TGA (Thermal Gravimetric Analysis) is the traditional method ...


    By Spectro Scientific

  • Biodiesel Analysis with Mid Infrared - From Feedstock to Fuel

    Introduction The biofuels industry is growing rapidly and so is the need for analysis to ensure quality product. The parameters for quality biodiesel require different types of instruments and measurement systems, such as gas chromatographs (GC), titrators, centrifuges, infrared spectrometers... Although claims are out there for the analyzer that will do it all, unfortunately there is no one ...


    By Spectro Scientific

  • Solvent choices for infrared testing of oil and grease in water

    Water is a very strong absorber in the mi d infrared (I R) regio n where o il is measured. We see the effect of infrared absorbance when a cold bucket of water left in the sun is quite warm by afternoon due to the absorption of infrared energy as heat. When measuring part per million (ppm) oil levels with mid IR, the water absorbs so much of the infrared energy that the signal becomes saturated ...


    By Spectro Scientific

  • Upgrading from Pellistor Gas Sensors to Infrared Technology

    In this article Andy Avenell, Crowcon’s Fixed Systems Product Manager, considers the shift towards infrared (IR) gas sensor technology in the oil and gas industry. Abstract Flammable gases and vapours can present considerable dangers in many industrial applications, none more so than the processes involved in extracting, transporting and processing oil and gas. Fast and reliable ...

  • A novel spectrometer design for process and handheld infrared spectral measurements

    Introduction Infrared spectroscopy offers many unique advantages for measurements within an industrial environment. Historically, the technique has been used for a broad range of applications from the composition of gas and liquid mixtures to the analysis of trace components for gas purity analysis. In cases where a well-defined method of analysis is involved, such as the measurement of ...


    By CIC Photonics, Inc.

  • Comparison of EN 14078 and ASTM D7371 infrared biodiesel methods

    Infrared (IR) analysis is the most widely used measurement technology for measuring biodiesel in diesel. Both EN 14078 and ASTM D7371 methods use infrared as the analytical method and more specifically FTIR (Fourier Transform Infrared) spectroscopy. Infrared is a common spectroscopic technique used for quantitative and qualitative analysis. In the biodiesel measurement, the fatty acid methyl ...


    By Spectro Scientific

  • Measuring grain protein concentration with in-line near infrared reflectance spectroscopy

    The advent of near infrared (NIR) on-combine sensors gives growers the opportunity to measure the grain protein concentration of wheat (Triticum aestivum L.) during harvest. A study consisting of three sequential experiments (laboratory bench, combine test stand, and field) was conducted to evaluate the performance of an in-line, NIR reflectance spectrometer, referred to as the ProSpectra Grain ...

  • Infrared Analysis Reduces Regulatory Fats, Oil and Grease (FOG) Testing Costs and Provides Fast Results

    Wastewater professionals who are enforcing industrial effluent standards for fats, oil and grease (FOG) either must perform numerous gravimetric tests or spend a considerable amount of money with a contracted testing laboratory.  Infrared analysis. using portable instruments such as the InfraCal TOG/TPH Analylzers -provides an alternative which will significantly reduce costs and ...


    By Spectro Scientific

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics, Inc.

  • Portable IR Analyzers Provide Petroleum & Wastewater Industries with Accurate Oil Content Measurements

    Fixed filter infrared (IR) analyzers have been used to test oil levels in produced water on off-shore and on-shore drilling platforms for well over 45 years. U.S. EPA methods 418.1 and 413.2 were used extensively on a worldwide basis until the Montreal Protocol called for Freon (the solvent used in the analysis) to be phased out. Infrared analysis using tetrachloroethylene (perchloroethylene) is ...


    By Spectro Scientific

  • Get Comparable ASTM/EN Data for Biodiesel Blend Measurements While Saving Time and Money using Portable IR Analyzers

    Both EN 14078 and ASTM D7371 methods for measuring the percent biodiesel in diesel fuel use infrared analysis as the analytical method and are based around using an FTIR spectrometer which has the capability to do a multitude of analyses besides the biodiesel in diesel measurement. This is great for a laboratory where various biofuels measurements are required. However, if the only measurement ...


    By Spectro Scientific

  • Portable IR Analyzer Provides ASTM Field Test Method for Measuring Soot Levels In Diesel Engine Lubricating Oils

    The InfraCal Soot Meter, from Wilks Enterprise, gives users an approved ASTM testing method for measuring the percent level of soot in diesel engine lubricating oils -- ASTM Method D7686-2011 entitled “Test Method for Field-Based Condition Monitoring of Soot in In-Service Lubricants Using a Fixed-Filter Infrared (IR) instrument.” While there is widespread disagreement on used-diesel ...


    By Spectro Scientific

  • Portable IR analyzers: the ideal measurement solution for biofuels blend quality and wastewater testing

    Two challenges facing the biofuels industry involve compliance with blend quality standards and wastewater regulations. According to a study done by the National Renewable Energy Laboratory, 1 the chief problem found with biodiesel blends was inaccurate blend ratios. Retail customers and fleet managers do not typically worry about whether the blend ratio is correct until a problem occurs. For ...


    By Spectro Scientific

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you