landfill leachate Articles

  • Landfill leachate treatment

    Landfills are categorized by regulations in three types: industrial, municipal, and hazardous. Individual landfills may be further differentiated by the types of waste which they accept. All landfills are required to be capped, usually occurring at the end of each day. The cap is typically 6-8” of soil. The cap reduces odor and loss due to wind. At the closing of the landfill, a permanent ...


    By WesTech Engineering, Inc.

  • Electrochemical treatment of landfill leachate

    Electrochemical methods can offer an elegant contribution towards environmental control as electrons provide a means of removing pollutants by redox reactions. In the process of electrochemical oxidation the main aim has been to convert oxidisable species into carbon dioxide. Leachate originating in landfills is complex wastewater that could exert high environmental impact. This study aims to ...


    By Inderscience Publishers

  • Landfill leachate treatment

    The Client The client is part of a group operating at an International level in many sectors and is highly experienced in many aspects of environmental services. The company provides the Region with many different services including street cleaning, waste collection and transport, graveyard services, public gardens maintenance, building and management of waste disposal plants, ecological ...

  • Landfill leachate treatment

    BOYDEL is pleased to confirm that we have produced great results running a heavily fuel and metals laced municipal landfill leachate through our LMR electrocoagulation reactor. The attached picture essentially speaks for itself except that the clear BOYDEL treated effluent is free of fuel smell and that the sludge depicted on the right side of the picture has not been further dewatered and is ...

  • Treatment of landfill leachate by effective microorganisms

    Five dominant strains, capable of treating leachate effectively, were isolated. The results showed that the removal efficiency of COD by using the mixed strains was higher than the pure strain, reaching 46.8%. The optimal inoculum concentration and the treatment time were 10.0% and 120 h respectively. The removal rate of COD reached the maximum at the temperature of 35°C and pH of 7.0. The ...


    By Inderscience Publishers

  • Landfill Leachate Sources and Treatment Options

    What is leachate? In a lab, it is any liquid that extracts solids as it passes through matter. In a landfill, it is the water that enters the facility in a number of ways, passes through waste material on contact, contains a wide range of constituents, and must be addressed with a proper operations plan. Leachate treatment options and mitigation are one of the greatest costs for landfill ...


    By Agru America, Inc.

  • Sequential treatment of an old-landfill leachate

    This work investigates the performance of combined techniques applied to the treatment of an old-landfill leachate, which presents high salinity, low biodegradability (BOD5/COD around 0.05) and high ammonia concentration. Three sequences of processes were employed, including coagulation/flocculation, chemical oxidation, biological treatment and ammonia stripping. The association of ...


    By Inderscience Publishers

  • What are the treatment options for landfill leachate?

    New contributor to Water/Waste Processing aims to answer readers’ most pressing questions It’s said the United States has 1,654 landfills, handling more than 250-million tons of trash each year. One Washington landfill covers a 2,545-acre area, has a 120-million-ton capacity and a 40-year expected trash-receiving life. The facility, the Republic ...

  • Fungi immobilization for landfill leachate treatment

    This paper investigated treatment of landfill leachate collected from Nonthaburi landfill site, Thailand, by using immobilized white rot fungi, namely, Trametes versicolor BCC 8725 and Flavodon flavus BCC 17421. Effects of pH and co-substrates were investigated at different contact times. Three types of co-substrates as carbon source used in this study are glucose, corn starch ...


    By IWA Publishing

  • Modeling Leachate Contamination and Remediation of Groundwater at a Landfill Site

    Leachate contamination of an aquifer from a landfill sitewas simulated using the groundwater flow and transport model SUTRA developed by the U.S. Geological Survey. The model calibration was performed by spatially adjusting the hydraulic conductivity in order to capture the measured hydraulic head spatial variation and then by adjusting the dispersivity and porosity match the measured chloride ...


    By Springer

  • Leachate treatment solution for council – Landfill Site, Camarthenshire

    Plant Equipment: Ocean Professional Nitrification Plant Design Data: Effluent target (NH4-N): <4 Daily flow (m3/day): 120 Ammonia load (kg/day): 6 BOD load (kg/day): n/a Situation and Problem This site comprises of six landfill cells and phase ...


    By EnSo International Ltd

  • Influence of magnetic treatment on the improvement of landfill leachate treatment

    Magnetic treatment is an alternative simple approach by which landfill leachate treatment could be improved. The purpose of landfill leachate treatment is to remove the Suspended Solids, Chemical Oxygen Demand (COD) and Biochemical Oxygen Demand (BOD). Based on experiment by using circulation flowing system with a magnetic strength of 0.55 T, it was shown that the leachate quality could be ...


    By Inderscience Publishers

  • Landfill Leachate Containing VOCs, BNAs, and Phenolic

    Southwest, USA AQUAMEND™ performance has been validated on landfill leachate containing a wide variety of volatile organics, base neutral acid extractable (BNA) compounds, and phenolics. The target compounds included methyl ethyl ketone (MEK), methyl isobutyl ketone (MIBK), and acetone. These compounds have traditionally been difficult or expensive to remove from wastewater using existing ...


  • Municipal landfill leachate treatment by SBBGR technology

    The paper reports the results of a laboratory-scale investigation aimed at evaluating the performance of a periodic biofilter with granular biomass (SBBGR) for treating leachate coming from a mature municipal landfill. The results show that the SBBGR was able to remove roughly 80% of COD in leachate. The remaining 20% of COD were, therefore, presumably owing to the presence in the leachate of ...


    By Inderscience Publishers

  • Preparation and Performance of Inorganic Coagulant for Landfill Leachate Pretreatment

    Landfill leachates are often defined as hazardous and heavy polluted wastewaters. It may contain large amount of organic matter, ammonia-nitrogen, heavy metals, chlorinated organics and inorganic salts (Wang et al. 2002). Proper treatment of leachate has therefore been a challenging problem confroting the local authorities. Anaerobic digestion or/and aerobic activated sludge methods are the most ...


    By Springer

  • Combined Landfill Gas and Leachate Extraction Systems

    There is currently a shift of emphasis in the approach to treatment of landfill gas and leachate. Until recently, there have been two disparate schools of thought concerning the collection and disposal of these two by-products of organic waste degradation within the same bio-reactor. The tendency in the past has been to study gas and leachate as separate problems each of which requiring a ...


    By QED Environmental Systems

  • Ultrafiltration and Reverse Osmosis for Landfill Leachate Treatment

    Lanchester Landfill serves Eastern Lancaster County and Western Chester County in PA for disposal of household and construction waste. The facility produces around 10,000 gals per day of leachate. The Problem The facility ran a single basin sequential batch reactor (SBR) and a filter press to dewater the solids for many years, but found that they first, could not sustain a ...


    By Dynatec Systems Inc.

  • Co-treatment of old landfill leachate and municipal wastewater in sequencing batch reactor (SBR): effect of landfill leachate concentration

    Sequencing batch reactor (SBR) was assessed for direct co-treatment of old landfill leachate and municipal wastewater for chemical oxygen demand (COD), nutrients and turbidity removal. Nitrogen removal was achieved by sequential nitrification and denitrification under post-anoxic conditions. Initially, SBR operating conditions were optimized by varying hydraulic retention time (HRT) at 20% ...


    By IWA Publishing

  • Leachates: Technologies for onsite sustainable leachate management

    Municipal landfill leachate is characterized by high concentrations of recalcitrant organic compounds, ammonia, suspended material and heavy metals. As a result, leachate is difficult to manage because conventional forms of biological and chemical treatment are inefficient at dealing with such a diverse and complex waste stream. Because of widely varying practices in solid waste management, an ...


    By Waste Advantage Magazine

  • Landfill leachate treatment for biological nutrient removal from wastewater

    Substantial volumes of leachate have been generated at the recently opened lined cells of the Orange County Landfill located in central Florida. To accommodate these volumes, a force main was installed to deliver leachate to the Eastern Service Area Wastewater Treatment Facility (ESAWTF) operated by the Orange County Public Utilities Division, which uses a biological nutrient removal process. ...


    By Inderscience Publishers