laser diode gas monitoring Articles

  • Operating Principle of an Oxygen Monitor

    The oxygen concentration in the flue gas of a combustion process such as that of a power plant or a waste incinerator gives a good indication of the efficiency of the combustion process. The parameter is therefore of great interest to optimize fuel economy, but also to control and reduce emissions of air pollutants. An ideal combustion process only results in CO2 and water, but ...


    By Opsis AB

  • Low level moisture measurement in Natural gas using a Lunable diode laser absorption spectroscopy (tdlas) based laser case study

    Introduction The measurement of water vapor in natural gas has long been of industrial importance, and has been addressed by a variety of analytical techniques over the years. Chief among these techniques has been the quartz crystal microbalance (QCM) based analyzers. The QCM technology is still the workhorse for production and pipeline applications, and the technique is considered by most ...

  • Laser Gas Detector LGD F200

    Laser gas detection with innovative, easy-to-integrate OEM modules Diode Laser based gas detection gains increased interest in the industry as it offers significant benefits in terms of selectivity, stability and low maintenance. Axetris provides innovative gas detector modules as basis for extractive process control systems and for continuous emission monitoring systems (CEMS). The ...


    By Axetris Ag

  • Insitu analysis of ammonia slip and water vapor using a tunable diode laser for SCR/SNCR optimization and boiler tube surveillance in power plants

    ABSTRACT Environmental Regulations driven by the 1990 Clean Air Act require Power Plants to reduce NOx emissions. SCR's and SNCR's reduce NOx emission by injecting ammonia into the combustion flue gas. which ideally reacts with the NOx to form H?0 and Nj. The efficiency of the SCR SNCR is determined by monitoring the outlet for excess NH3. referred to as NH3 slip. The flue gas sample ...

  • Laser gas detection is now cheap, fast and reliable

    Laser based gas detectors are now being used in a wide variety of applications for process and quality monitoring, and safety and environmental compliance. The reasons are that laser detectors are more reliable and less expensive than alternative solutions. Laser detectors combine semiconductor tunable diode lasers (TDL) and optical fibres developed by the telecommunications industry with ...


    By Boreal Laser Inc.

  • A Comparison of Point Sensors and Open Path Monitors For Toxic Gas (esp. HF) Monitoring

    Point Sensors Ion Mobility Spectroscope (IMS) – a gas sample is ionized by a radioactive source (Ni63). Differences in ion drift under the influence of an applied electric field produce a spectrum that is dependent on the mass, charge, and shape of the component ions. The detector signal and strength is tuned to the drift time of the ion of interest (in this case HF) and signal strength is ...


    By Boreal Laser Inc.

  • Safety Monitoring in HF Alkylation Units

    How GasFinder works Boreal Laser’s GasFinder & GasFinder MC are open-path gas detectors that use an integrated transmitter/receiver unit and a remote, passive retro-reflector. In GasFinder (see below) the transceiver also houses the laser diode, drive electronics, detector module and micro-computer subsystems. The transceiver unit is contained in an IP65 enclosure and has connectors for power ...


    By Boreal Laser Inc.

  • TDLAS Gas Detection Instrumentation

    PKL Technologies Inc. manufactures tunable diode laser (TDLAS) based gas detectors and monitors. Spectra-1 open path gas sensors are used in a variety of environmental and safety remote sensing applications. Spectra-1 gas sensors have been designed in a compact, easy to use, robust and portable format. Spectra-1 has been developed using proprietary hardware and software, to produce a low cost ...


    By PKL Technologies Inc.

  • The Application of a Laser Based Open-Path Spectrometer for the Measurement of Fugitive Emissions and Process Control.

    ABSTRACT In this paper examples of field operations are presented explaining the application of a new laser based spectrometer and incorporating real-time dispersion modeling techniques to measure fugitive emissions from land fills, gas processing facilities, chemical plants, aluminium smelters, etc. Whilst open-path FTIR spectrometers can measure a variety of gases, ...


    By Boreal Laser Inc.

  • High sensitivity CO2 monitor for CO2 geological sequestration efficiency monitoring

    Canadian prosperity is currently linked to revenue generated from processes that produce large volumes of greenhouse gasses as a by-product. Under evidence that the human fingerprint on our planet is in direct correlation to global climate change, the monitoring and control of greenhouse gas emissions has become a subject of recent focus among many sciences. Recently, legislation has been imposed ...


    By Boreal Laser Inc.

  • Continous Emission Monitoring (CEMs)

    Presented in Track B1: CEMs at EUEC 2011,January 31 Phoenix, Arizona   B1.1  | Particulate CEM for wet FGD plant William Averdieck |  Managing ...

  • Axetris achieves Silver Gas Award 2013

    Here the original text from G&I: „The Axetris AG LGD F200 self-contained laser gas detector module is designed for integration by original equipment manufacturers (OEMs) of selective catalytic reduction (SCR) systems and monitoring equipment and is based on proprietary technology- enhanced tuneable diode laser spectrometry. The OEM module can measure concentrations from well under ...


    By Axetris Ag

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...

  • Effective elimination – Case Study

    The LDS 6 laser diode spectrometer supports the effective, safe, and environmentally friendly elimination of odorous gases. Applications in the oil and gas industry are exactly the type of challenge the LDS 6 laser diode process gas analyzer was designed for: sites where high performance and ease of use rank on a par with increased productivity and safety. Those were the requirements of a ...

  • TDLS for a Cleaner Environment - Case Study

    In this case study for Axetris Laser Gas Detection (LGD) products, Urs F. Boegli – Senior Application Engineer - looks at the historical perspective on the development of environment regulation and emission control technology. The European Community has published several directives to harmonize the legislation on industrial emissions. These include the Large Combustion Plant Directive ...


    By Axetris Ag

  • Real Time Measurments of Acetylene in Ethylene Manufacturing Process

    Keywords Tunable Diode Laser, Wavelength Modulation Spectroscopy, Analyzer, Acetylene, Ethylene, Acetylene Converter Abstract The analyzer, based on near infrared Tunable Diode Laser Absorption Spectroscopy (TDLAS), was developed for the measurement of acetylene in process streams. Measurements of acetylene were made as under laboratory conditions and in ...

  • Introducing LaserGas III SP CO – a combustion analyzer for rough environments

    NEO Monitors unveils the industry’s most compact CO combustion analyzer suitable for the most demanding environments. LaserGas III CO includes measurement of CH4, H2O and temperature in one single unit designed to reduce risk. Based on decades of experience and customer feedback, NEO Monitors has designed an Ex-d certified tunable diode laser (TDLS) analyzer. The instrument is ...


    By NEO Monitors AS

  • Increasing safety in waste water treatment plants – Case Study

    BP in Geel/Belgium runs the largest PTA plant in Europe. Purified Terephthalic Acid (PTA) is the preferred raw material for the most common plastic products of daily life. It serves to make polyester fibers, polyester films, PET bottle resins, and to other polyester thermoplastic products. BP produces around 30 million tones per year which is 30 % of the worlds production of PTA. The TPA ...

  • LDS 6 improves an incineration process and provides a positive environmental impact – Case Study

    The customer A chemical company, located in Gent/ Belgium, produces as part of their production processes highly concentrated sulfuric acid. This process involves a high temperature operated incineration. The new in-situ measurement replaces a conventional measuring technology, which was subject to extensive maintenance and created high operation costs. Roughly spoken, the ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you