low flow monitoring Articles

  • Low flow investigations: Severn Trent

    Over the last eight years ESI has worked closely with Severn Trent Water on key low flow sites in the Midlands.  The work has spanned the AMP3 and AMP4 programmes in 18 catchments and reviewed a total of over 30 PWS abstraction boreholes. The sites were initially flagged up for investigation as part of the National Environment Programme by the Environment Agency and included several SSSIs ...

  • Groundwater: Low-flow Purging and Sampling

    Significant timesavings, improved sample process integrity, quality assurance and minimal quantities of potentially contaminated purge water to manage - are attractive as the focus on groundwater quality sharpens and economics demand best cost-benefit based methods Water has become a vitally important resource.  Maintaining its quality and quantity and avoiding pollution are set to be ...


    By Geotech

  • Two Detector Solution to Analyzing Sulfur

    Sulfur compounds are reactive, corrosive to pipes, and destructive to catalysts in petroleum refineries. Sulfur emission are strictly regulated globally. When released into the atmosphere sulfur dioxide converts to sulfuric acid resulting in adverse effects on human health and the environment. Sulfur detection is found useful in many other industries; therefore, detection of sulfur compounds in ...


    By Restek Corporation

  • 100 Simple Ways To Save Water

    To improve water conservation install a rain sensor, it turns off your irrigation when it rains. Use a weather-based controller. The use of smart controllers can reduce water usage 24% a year on average. Learn about available rebate programs ...


    By Jain Irrigation, Inc

  • Lagoon Discharge Flow Monitoring

    Open Channel Flow Monitoring without a Flume or Weir Township operators liked the Greyline AVFM 5.0 datalogger reporting system where formatted flow reports (total, minimum, maximum and average) could be downloaded automatically to a USB memory stick without carrying a laptop to the site. The Township of South Glengarry in Eastern Ontario discharges continuously from their ...


    By Greyline Instruments Inc.

  • Groundwater Remediation at Low Flow/Low Permeability Sites using HRC

    Rocky Flats Environmental Technology Site (RFETS) is located near Golden, Colorado. A groundwater plume of tetrachlorethene (PCE) and other volatile organic compounds (VOCs) developed at the PU&D Yard site as a result of prior spills at this location. A treatability study evaluated the effectiveness of the Hydrogen Release Compound (HRC®) in low-flow groundwater regimes. HRC is a proprietary, ...


    By REGENESIS

  • Low-Flow Purging Reduces Management of Contaminated Groundwater

    Purging a monitoring well prior to sampling removes stagnant water in the well casing and ensures collection of groundwater samples representative of formation water. Traditionally, a number of well casing volumes are removed (from three to five) and water stabilization parameters are monitored during removal of the casing volumes. Temperature, pH and specific conductance are routinely monitored ...


    By QED Environmental Systems

  • Low-Flow (Mininimal Drawndown) Ground-water Sampling

    The Regional Superfund Ground Water Forum is a group of ground-water scientists, representing EPA's Regional Superfund Offices, organized to exchange information related to ground-water remediation at Superfund sites. One of the major concerns of the Forum is the sampling of ground water to support site assessment and remedial performance monitoring objectives. This paper is intended to provide ...


    By GeoPump, Inc.

  • Scottish Water Flow Monitoring Contracts

    Scottish Water commissioned HL in 2007 to deliver two separate flow monitoring contracts to help improve the water companies understanding of the yield and low flow conditions at several water supply catchments across Scotland. One project involved the installation of reservoir level, inflow flow gauges and recording raingauge devices in nine reservoir catchments in South West Scotland. Although ...

  • Low-Flow (Minimal Drawdown) Ground Water Sampling Procedures

    The Regional Superfund Ground Water Forum is a group of ground-water scientists, representing EPA’s Regional Superfund Offices, organized to exchange information related to ground-water remediation at Superfund sites. One of the major concerns of the Forum is the sampling of ground water to support site assessment and remedial performance monitoring objectives. This paper is intended to provide ...


    By QED Environmental Systems

  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

  • Case study - Low-flow groundwater sampling on a nuclear site

    Nuclear licensed site use of low-flow groundwater sampling shows: Reduced time, reduced quantity of purge water – both thus reducing cost - and reduced risk of operator contact especially with potentially radioactive-contaminated purge water thanks to a self-contained enclosed system. One of the biggest headaches on site is the purge water and the expense of getting rid of it – after ...


    By Geotech

  • Low Flow Groundwater Sampling Using RotaPump Inertial Lift Pump

    This article tells you how to perform low flow groundwater sampling using a portable, surface-mounted pump with no decontamination required before each use and  no chance of cross contamination between wells. An inertial lift pump moves a dedicated (stored in the well) pumping tube rapidly up and down.  A one-way valve on the bottom admits water on the down stroke and ...


    By RotaPump, Inc

  • Case of Study – Low nitrification

    BM Respirometer The respirometer utilized for the study was a BM-T, provided with external thermostatic unit (bath) This “batch system” respirometer consists of: a single reactor vessel, divided into two interconnected compartments with closed recirculation loop between the two. Both compartments are kept completely mixed by means of paddle stirrers and a peristaltic recirculation A ...


    By SURCIS, S.L.

  • Effective monitoring improves sewage flow management case study

    SmartScan 50 introduces an effective solution for flow measurement of sewage water in one of Poland's municipal waste water treatment plant. The city of Zblewo, Poland provides waste water treatment services to its inhabitants. The plant sought an ultrasonic measurement solution for monitoring the raw sewage flow during the treatment process. The problems When entering the ...

  • AVFM 5.0 area-velocity flow meter monitors sewage lagoon discharge flow

    The Township of South Glengarry in Eastern Ontario discharges continuously from their 72,000 m3 sewage lagoon. But they ran into flow measurement problems when their magnetic flowmeter was unable to detect seasonal low flow rates. Operations Manager, Shawn Killoran selected a Greyline AVFM 5.0 Area-Velocity Flow Monitor because it was simple to install in a horizontal discharge pipe from the ...


    By Greyline Instruments Inc.

  • Development of ultrasonic streamflow monitoring system using an existing low head broad-crested agricultural small dam

    In this study, we developed a system of continuous accurate monitoring of streamflow, which is composed of a pair of ultrasonic Doppler velocity sensors installed on an existing low head broad-crested agricultural small dam. In case of using this dam, errors in computing area are minimized due to stability of it, so that discharge can be accurately measured. In addition, by direct measurement of ...


    By HydroVision GmbH

  • Online flow measurement

    Background The undershoot weir in Hohensaaten was built in 1913. It has three openings and regulates the discharge from the Oderbruch and from the Finow canal into the Hohensaaten-Friedrichsthaler-waterway. Moreover, it protects parts of the Oderbruch against Oder floods. The weir controls the waterlevels in the Havel-Oder-waterway and in the reach of Niederfinow- Hohensaaten. ...

  • DOD evaluates bioaugmentation for remediating low-pH aquifers

    The US Department of Defense (DOD) has completed pilot-scale work on the 'MAG-1' site at Fort Dix, NJ, to test suitability of anaerobic bioremediation for an aquifer with low pH. Project results will be used to design full-scale ground-water treatment at MAG-1. In addition, technical criteria gained from the demonstration will be integrated into DOD’s remediation strategy for its many facilities ...

  • Active leakage control in low pressures - It can be done!

    Leakage and PressureWater when leaving the pipe creates an ‘energy’ and it is this energy that is transferred through the water and the pipe wall by the means of acoustic sound. This acoustic sound depending on the material of the pipe work either dissipates over a long distance or is absorbed very quickly into the pipe wall. The effect being that for metallic or hard walled pipes the sound ...


Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you