low gas flow monitoring Articles

  • Dry Air Scrubber for Propylene Oxide

    Background For decades, Advanced Air Technologies, Inc. has been the leader in air scrubber  technology for abatement of Ethylene Oxide (EtO) emissions.   In fact, AAT, Inc. was founded in 1987 on a unique dry scrubbing, chemi-sorption process for EtO.  The result is a series of fixed bed “Safe-Cell II” dry scrubbers, consisting of the DR-490, DR-50, and ...

  • Groundwater: Low-flow Purging and Sampling

    Significant timesavings, improved sample process integrity, quality assurance and minimal quantities of potentially contaminated purge water to manage - are attractive as the focus on groundwater quality sharpens and economics demand best cost-benefit based methods Water has become a vitally important resource.  Maintaining its quality and quantity and avoiding pollution are set to be ...


    By Geotech

  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

  • Measuring and interpreting gas flow from landfill boreholes case study

    Current landfill gas measurement practice for measuring the gas composition is well understood, and there are standard procedures and instruments available to analyse the gas. It is also current recognised practice to measure the gas 'flow' from boreholes to monitor the production of gas in a landfill site. If care is taken to make the measurement in the same way each time, changes in the ...


    By Geotech

  • 10 Reasons why you should continuously monitor low temperature and liquid chemical sterilants for worker safety

    1. Sterilant chemicals are highly toxic Low temperature and liquid chemical sterilants are designed to kill all microorganisms including resistant spores and if they were not toxic, they would not be effective in sufficiently high concentration to destroy all microbial life including the chemically resistant sporicidal forms of certain ...


    By ChemDAQ, Inc.

  • Low emissions from large plants too

    Type     HOFGAS®- LPM 3000 Performance     3’000 Nm³/h, 15’000 kW Location     Scotland (GB) SituationEvery year, 150’000 tonnes of waste from Edinburgh, Lothian and the Borders Region are brought to the Dunbar landfill site. The waste is transported by rail to the site. In 2002, the UK Environmental Agency ...


    By Hofstetter BV

  • PureAire Combines Oxygen and CO2 Sensors to provide a Dual Gas Monitor to the Marketplace

    As a recognized leader in O2 safety monitoring, PureAire recently explored the need for an O2 monitor where carbon dioxide is used. There are four key cryogenic gases; nitrogen, helium, argon, and carbon dioxide (CO2), which can create an oxygen deficient atmosphere. Material Safety Data Sheets (MSDS) covering cryogenic gases cite that a cryogenic leak can create an unsafe ...

  • Wastewater Plant Relies on Thermal Flow Meter for Co-Gen Power Gas Blending Process

    The Rahway Valley Sewerage Authority (RVSA), which operates a large wastewater treatment plant in New Jersey, embarked on a green co-generation waste-to-energy project to power a portion of its operations. The plant performs primary, secondary, tertiary and sludge treatment processes in serving over 250,000 residential customers and 3000 industrial and commercial customers in a 40-plus square ...


    By Modern Pumping Today

  • The benefits of monitoring compressed air

    Compressed air is used in many manufacturing processes for many different reasons, from the actuation and control of pneumatic valves and cylinders to the operation of process machinery and tooling. It can also be used as a transport medium for bulk materials or as a purge gas. For all its uses it is nonetheless expensive. This is why, through detailed monitoring, a business can enjoy the ...


    By Contrec Europe Limited

  • Detection of moisture in ammonia gas

    Problem Statement As technologies advance, so does the request for ultra high purity ammonia. Ultra high purity (UHP) ammonia is used in the semiconductor industries, production of flat panel displays, and a number of other applications. Due to this rising interest in UHP ammonia, manufacturers are having to battle ammonia’s most prominent and damaging impurity--moisture. For ...


    By CIC Photonics, Inc.

  • Greenstars portable monitoring for CHP and flares

    Greenstar’s award-winning KTK landfill site in Kilcullen, Co. Kildare, is unusual in Ireland in that it has three gas engines feeding electricity to the grid and two flares. In Ireland, while flaring is common, engines are not. The flares are run in tandem with engines so that if an engine is ramped down for repair or service, the flare ramps up automatically. All are supplied by 122 ...


    By Geotech

  • Measuring of landfill gas production

    Type     HOFGAS®- Smarty S  Commissioning     2002 Site     Nurmijärvi (FI) Situation An accurate estimation of the landfill gas production will support the operator at the Nurmijärvi landfill site in planning the final gas collection and degassing system. A mobile degassing plant was installed to measure the quantity ...


    By Hofstetter BV

  • Recapping the Debate Over Whether Low-Carbon Economies Are Good for Tech

    To be of any use, tech products need power from electrical outlets, stored chemical energy such as batteries and generators, solar collectors, kinetic energy like my emergency hand-crank radio/charger, or other means. As more global and local regions move away from fossil-fuel-based power to low-carbon renewable power, I wonder how my colleagues in the tech industry would weigh in on a debate ...


    By Antea Group - USA

  • One step, low pH iron and organics removal - Case Study

    Review For over seven years, the semiconductor facility performed routine on-site cleans of their reverse osmosis (RO) membranes using RoClean P111 with good results. However, over a six month period in 2015, membrane cleaning frequency increased to once a month and permeate flows could not be sufficiently restored. An Avista application specialist visited the site to personally monitor the ...


    By Avista Technologies

  • Understanding the Benefits of Fixed Gas Detection

    "Fixed gas detection is an essential method of ensuring maximum protection for personnel and plant. There are a variety of technologies available for a multitude of applications. Understanding fixed gas detection is the first step in providing safety." What is fixed gas detection? Fixed gas detection is installed with the aim of providing continuous, area and personnel protection. ...


    By a1-cbiss

  • Flow measurement technology comparison: GA5000 Vs Hot Wire Anemometer

    A typical landfill or contaminated land site under investigation will comprise of a suitable number of gas monitoring wells, with a planned series of monitoring visits.  The monitoring will include gas flow measurements, which together with methane and carbon dioxide concentrations will be used to calculate gas screening values (GSV) and hence allow the determination of whether any gas ...


    By Geotech

  • Greenstars portable monitoring for CHP and flares case study

    Greenstar's award-winning KTK landfill site in Kilcullen, Co. Kildare, is unusual in Ireland in that it has three gas engines feeding electricity to the grid and two flares. In Ireland, while flaring is common, engines are not. The flares are run in tandem with engines so that if an engine is ramped down for repair or service, the flare ramps up automatically. All are supplied by 122 landfill gas ...


    By Geotech

  • Continuous monitoring of moisture present inside a process chamber

    Problem Statement Moisture inside a process chamber is a big silent killer during wafer production. When production yield goes down, it is hard to pinpoint the source of the problem. Most of the time wafers need to be sent to labs for analysis, while production is stopped. If the problem is related to a high level of moisture inside the reactor, there are several factors that can cause ...


    By CIC Photonics, Inc.

  • Monitoring Oil in Cooling Water - Case Study

    The Situation A municipal power plant in the southern United States operates more than 10 stationary power plant engines capable of producing 52 megawatts of electric power. The plant is part of a larger statewide power grid system. Within the grid, the municipality brokers the purchase or sale of power hourly, based on the needs of municipality and the market rate for power on the grid ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you