manganese filter media Articles

  • Filtration and manganese removal

    Manganese removal through a filter bed is generally carried out and accepted by practitioners and researchers as occurring through catalytic oxidation at the surface of MnO2 coated media, although manganese passage through a coated media filter has been little investigated. To better understand the kinetics of Mn removal through a naturally coated filter, a pilot plant consisting of four filter ...


    By IWA Publishing

  • Effectiveness of oxidative filter materials for manganese removal from groundwater

    The experiments reported in this paper were conducted at a pilot plant consisting of filtration columns filled with oxidative filter materials. The installation was supplied with water containing manganese in concentrations ranging from 0.2 to 1.4 mg/L. The aim of the experiments was to determine the effectiveness of manganese removal on the three filter media as a function of their internal ...


    By IWA Publishing

  • Project profile - Foxxtown Apartments Sudlersville, Maryland arsenic, iron & manganese removal

    Background AdEdge Technologies Inc. (AdEdge) was selected in 2006 by McCrone Engineers and the awarded contractor, Maryland Construction to design, build, and install a full scale AD26GS+ arsenic, iron, and manganese treatment system for their customer Foxxtown Apartments in Sudlersville, Maryland to meet the new EPA arsenic standard. The treatment system was based on the design ...

  • Project profile - Village of Corona, NM iron and manganese reduction

    Background In the fall of 2008, AdEdge was selected by Village of Corona, NM to design, manufacture, and startup a water treatment system for the removal of iron and manganese. The water system that serves approximately 100 connections at Corona was plagued by high iron and manganese in the main water supply with iron from 0.26 – 2.8 mg/L and manganese levels from 0.094 - 0.17 ...

  • Industrial Media Filtration Systems, Philippines

    INTRODUCTION In July 2013, Pure Aqua successfully manufactured industrial media filtration systems to a major company in Philippines to remove particulates, chlorine, organics, and odor from well water. The industrial media filtration systems were selected from our MF-1000 Series with 48" and 42" diameter ...


    By Pure Aqua, Inc.

  • Project profile - Melody Woods Water Company Los Gatos, California iron and manganese treatment system

    Background In February 2009, the Melody Woods Water Company selected and began working with AdEdge Technologies to assist with the design and implementation of a Manganese, Iron and Turbidity treatment system to serve the water supply for Melody Woods in Los Gatos, California. The site has two existing groundwater supply wells that provide drinking water for approximately 53 connections ...

  • Green Sand Filters, Chile

    INTRODUCTION In August 2013, Pure Aqua, Inc. manufactured and supplied Green Sand Filters to a major company in Chile to lower the manganese and iron level in well water. The system came complete with tank, top mounted valves, and high quality green sand media. The system was designed to produce 24 GPM. Since the initial startup, ...


    By Pure Aqua, Inc.

  • Effect of oxygen deprivation on treatment processes in a full-scale drinking water biofilter

    Dissolved oxygen is critical for proper operation of waterworks that utilize anaerobic groundwater and rely on biofilters to remove iron, manganese and ammonium. In these biofilters, planned or inadvertent oxygen deprivation may occur for a variety of reasons. The water quality effects of oxygen deprivation on the function of drinking water biofilters, however, have not previously been reported. ...


    By IWA Publishing

  • Control of metal oxide fouling in reverse osmosis

    High levels of iron and manganese, along with large quantities of dissolved gases in the wells created concern for the viability of a conventional desalination design for the proposed City of Camarillo groundwater desalination facility. To identify viable pre-treatment process(es) for the control of metal oxide fouling in reverse osmosis, a 12-month pilot study was undertaken. The pilot study ...


    By Toray Chemical Korea

  • Control of metal oxide fouling in reverse osmosis

    High levels of iron and manganese, along with large quantities of dissolved gases in the wells created concern for the viability of a conventional desalination design for the proposed City of Camarillo groundwater desalination facility. To identify viable pre-treatment process(es) for the control of metal oxide fouling in reverse osmosis, a 12-month pilot study was undertaken. The pilot study ...


    By Toray Chemical Korea

  • The role of backwash in start-up of full-scale drinking water biofilters

    The purpose of backwashing during the start-up period of rapid biofilters at drinking water treatment plants differs significantly from the purpose of backwashing during normal operation. During start-up, finished water quality is secondary, detachment of microorganisms must be minimized, dust present in the original filter media must be removed and inherent inoculation of the biofilter with ...


    By IWA Publishing

  • Talkeetna Water System, Alaska - Case Study

    In late 2009, VEI Consultants contacted AdEdge Water Technologies to design, implement and startup an arsenic, iron, and manganese treatment system for the Talkeetna Water System in Talkeetna, Alaska. The existing water supply consisted of a well rated for 250 gpm with an arsenic level of 20 parts per billion (ppb). Iron and manganese levels were 0.04 mg/L and 0.10 mg/L respectively. The water ...

  • City of Stromsburg, Nebraska - Case Study

    In May 2011, AdEdge Water Technologies was selected among other vendors by Miller & Associates to supply a turnkey arsenic and manganese treatment system for the Village of Stromsburg, Nebraska. Arsenic levels in the water ranged from 0.0178 mg/L to 0.0276 mg/L and the manganese levels fluctuated between 0.05 mg/L and 0.12 mg/L, well above the EPA maximum contaminant levels of 0.010 mg/L ...

  • Biological drinking water treatment Hong Kong

    The water treatment works takes water from the river Dongjiang in the Guangdong Province north of Hong Kong. The raw water has an average turbidity level of around 11 NTU and contents, among other things, ammonia and manganese. Water temperatures range from 12 to 34oC.   During planning of the waterworks ...

  • Filtronics’ NSF Certified Electromedia sets the standard for water filtration industry

    The key to any water treatment system and its efficiency and effectiveness is its filtering media, or the sand or gravel that helps to remove pollutants and contaminants from a water source. Filtronics’ exclusive Electromedia is a permanent filtering media that is National Sanitation Foundation (NSF) ...


    By Filtronics, Inc.

  • Water Treatment Plant (Drinking Water) Indian Oil Corporation Limited, India

    W.O.G Groups responded to the challenge of providing safe drinking water to the Indian Oil Corporation Limited township by undertaking a Drinking Water Treatment Plant of Capacity 5.76 MLD, including 1 year O&M. CHALLENGE: The raw water is to be treated for the removal of Manganese, iron, turbidity, suspended solids, colour, organic matter and pH The design of ...


    By WOG Technologies Inc.

  • Park City, Utah Arsenic removal from ground water

    Background Park City Utah Water, which serves a population of 6,500, has five water sources. Spiro Tunnel and Spiro Portal are two that were in need of Iron and Manganese removal as well as above limits for Arsenic. Filtronics was engaged by the engineering firm of Eckhoff, Watson and Preator (EWP), Salt Lake City, to perform pilot tests for the Park City Municipal Corporation. The ...


    By Filtronics, Incorporated

  • Higher filtration rates mean better results for Filtronics customers

    Filtronics has been ahead of the curve in terms of providing create, effective and cost efficient water treatmentsystems for city water ...


    By Filtronics, Inc.

  • World War II Memorial, DC - Case Study

    In 2003, AdEdge Water Technologies began working closely with EarthTech, the assigned engineering firm responsible for specifying and selecting the various water treatment systems serving the new National World War II Monument in Washington, DC. Stormwater and groundwater control and treatment are essential aspects of this project given the location of the site on the Mall adjacent to the ...

  • Arica Pago de Gomez, Chile - Case Study

    Fast Facts Contaminant: Arsenic Flow Rate: 2.5 MGD In November 2011, AdEdge Water Technologies was contacted byXylem Inc to design, supply and start up an arsenic treatment system for Aguas del Altiplano in Pago de Gomez, Arica-Chile. The Pago de Gomez Water Treatment Plant added an arsenic treatment unit to its existing ...