monitor stack hazardous air pollutant Articles

  • Canarina DISPER Software · air pollution · algorithms 2

      Software · air pollution · algorithms 2   Symbol / Definition Ly= Initial plume length for Schulman-Scire downwash sources ...

  • General Environmental Guidelines Industry - Pollution Prevention Guidelines

    Introduction Pollution Prevention Guidelines to provide technical advice and guidance to staff and consultants involved in pollution-related projects. The guidelines represent state-of-the-art thinking on how to reduce pollution emissions from the production process. In many cases, the guidelines provide numerical targets for reducing pollution, as well as maximum ...


    By The World Bank

  • Continous Emission Monitoring (CEMs)

    Presented in Track B1: CEMs at EUEC 2011,January 31 Phoenix, Arizona   B1.1  | Particulate CEM for wet FGD plant William Averdieck |  Managing ...

  • A Breath of Fresh Air for Your

    As the full effect of the Federal Clean Air Act (CAA) Amendments continue to impact today’s industry, many companies will be required to install new or additional air pollution control equipment.  With over two decades of proven success, catalytic oxidation is a popular method for controlling volatile organic compound (VOC) emissions.During the past 25 years, industry has made progress in ...


    By The CMM Group, LLC

  • Nature’s Own - Biofiltration process offers promise of (near) energy-free pollution abatement

    A filter could be described as any substance through which liquid is passed to remove suspended impurities. Although a “biofilter” is actually not a filter, “biofiltration” is on the threshold of finding a market as a compliance solution for air pollution regulations after a number of false starts. Biofilters have long been used as a means for reducing objectionable odors in Germany, the ...


  • Canarina DISPER software · air emissions mapping · algorithms 10

      Canarina DISPER software · air emissions mapping    Unstable or Neutral - Crossover Between Momentum and Buoyancy. For cases with stack gas temperature greater than or equal to ambient temperature, it must be determined whether the plume rise is ...

  • Guide for developing a multi-metals, Fence-line monitoring plan for fugitive emissions using x-ray based Monitorsa case study

    Airborne metals and metal compounds are of particular concern to human health. Not only are they included in the United States (U.S.) Environmental Protection Agency’s (EPA) list of 187 hazardous air pollutants (HAPs), they represent 8 of the 33 urban pollutants identified by the EPA as posing the greatest potential health threat in urban areas. This is particularly significant since 80% of ...


    By Cooper Environmental

  • New boiler MACT and affiliated rules proposed

    EPA proposed three related rules (with final rules expected by December 16, 2010), intended to reduce the emission of hazardous air pollutants (HAPs) from industrial, commercial, and institutional boilers and process heaters as well as commercial and industrial solid waste incinerators. Simultaneously, it also proposed a definition of solid waste that could potentially affect some units currently ...


    By Trinity Consultants

  • Proposed boiler MACT sets aggressive emission limits

    On June 4, 2010, U.S. EPA proposed National Emission Standards for Hazardous Air Pollutants (NESHAP) for industrial, commercial, and institutional boilers and process heaters at both major and area sources of hazardous air pollutants (HAP) emissions.  EPA proposed separate rules for units at major sources of HAP emissions (greater than 10 tons per year [tpy] of any single HAP and/or greater ...


    By Trinity Consultants

  • Smart LDAR — more cost-effective?

    On December 19, 2008, EPA issued a final rule establishing a voluntary Alternative Work Practice (AWP) to detect leaks of volatile organic compounds (VOC) and hazardous air pollutants (HAP) from process equipment (FR Vol. 73, Number 246), thereby providing the regulated community additional flexibility in complying with leak detection and repair (LDAR) requirements. The AWP allows owners or ...


    By Trinity Consultants

  • Cementing the PC MACT

    On September 9, 2010, the U.S. EPA promulgated the final amendments to the National Emissions Standard for Hazardous Air Pollutants from Portland Cement Manufacturing Industry (40 CFR 63 Subpart LLL), also known as the PC MACT. EPA’s self-proclaimed “historic” rulemaking includes some important implications for cement manufacturers and other sources that may be subject to ...


    By Trinity Consultants

  • EPA finalizes boiler NESHAP

    EPA published the final National Emission Standards for Hazardous Air Pollutants (NESHAP) for industrial, commercial, and institutional boilers and process heaters at both major and area sources of hazardous air pollutants (HAP) emissions. EPA developed separate rules for units at major sources of HAP emissions (greater than 10 tons per year [tpy] of any single HAP and/or greater than 25 tpy of ...


    By Trinity Consultants

  • Common Treatment Technologies for Nonhalogenated VOCs

    Soil vapor extraction (SVE), thermal desorption, and incineration are the presumptive remedies for Superfund sites with nonhalogenated VOC-contaminated soil. Because a presumptive remedy is a technology that EPA believes, based upon its past experience, generally will be the most appropriate remedy for a specified type of site, the presumptive remedy approach will accelerate site-specific ...

  • PC MACT proposal may signal widespread change

    On May 6, 2009, EPA proposed amendments to the National Emission Standards for Hazardous Air Pollutants from the Portland Cement Manufacturing Industry (PC MACT) in response to numerous petitions and court mandates. The proposed revisions present significant challenges to the portland cement industry by establishing a new lower maximum achievable control technology (MACT) floor that would require ...


    By Trinity Consultants

  • To MACT and Beyond case study

    In the 1970s, FMC Corp., a chemical manufacturer headquartered in Philadelphia, began operating a high-efficiency thermal destruction facility to dispose of hazardous liquid wastes at its Baltimore pesticide manufacturing plant. The facility used a thermal oxidizer with a rapid quencher and packed tower scrubber to remove air pollution emissions. The system was upgraded in the early ’80s ...


    By Bionomic Industries Inc.

  • Reducing Odor and VOC Emissions

    The Montgomery County Regional Composting Facility (MCRCF) in Silver Spring, Maryland is designed to process 400 wet tons/day of lime amended biosolids from the Blue Plains Wastewater Treatment Plant (WWTP) in Washington, D.C. Recently, political pressures forced operations to cease at the MCRCF. Although the aerated static pile composting plant’s fate has not been completely decided, its owner, ...


    By BioCycle Magazine

  • Final CISWI rule

    On March 21, 2011, in parallel with publication of the Boiler National Emission Standard for Hazardous Air Pollutants (NESHAP) rules and the Non-Hazardous Secondary Material (NHSM) rule, EPA promulgated the final updates to the New Source Performance Standards (NSPS) and Emission Guidelines (EG) for Existing CISWI Units, collectively referred to as the “2011 CISWI Rules.”1 The 2011 ...


    By Trinity Consultants

  • Are incineration and landfills the answer to save us from the recycling crisis?

    For plastic recycling, this year hasn’t exactly been one of the best – what is to blame? Oil. Shockingly, it actually costs more to recycle old plastic than it does to make new in many ways. Petroleum prices have fallen so low, as low as 70% below the level in June 2014. This may be great for some – however with it has fallen the cost of Virgin Plastic which is made from ...


    By GPT Waste Management Ltd

  • Regenerative Thermal Oxidizers…What You Should Know.

    Within industry today, the use of an Air Pollution Control System (APCS) to control harmful air pollutants is not new.  In response to Congressional guidelines passed in the 1970’s, a number of companies with VOC emissions have been operating air pollution control systems of one type or another for 25 years or more.  These guidelines have been revised and added to as the years ...


    By The CMM Group, LLC

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you