monitoring well Articles

  • High frequency monitoring needed to protect UK rivers - Case Study

    The science behind nutrient pollution in rivers is still poorly understood despite the fact that nitrate and phosphate concentrations in the UK’s rivers are mostly unacceptable, although an element of uncertainty exists about what an acceptable level actually is. Key to improving our understanding of the sources and impacts of nutrient pollution is high-resolution monitoring across a broad ...


    By The OTT Hydromet Group

  • Water Quality Data Logger for Monitoring Coal Mine Runoff

    Water Quality Monitoring Solutions from dataTaker CAS DataLoggers provided an intelligent water quality data logging solution for an open-cut coal mine to monitor high salinity water runoff into local retaining ponds with a Water Quality Data Logger. The water from these retention ponds could only be released into the local river system when it was of sufficient quality to have no effect on the ...


    By CAS DataLoggers

  • The first monitoring well in Engbertsdijksvenen is a reality

    On Wednesday 20 December 2017, the first monitoring well of the groundwater monitoring network Engbertsdijksvenen was realised on the parcel of landowner Wilharms in Vriezenveen. This monitoring well serves to monitor the effects of the measures required for the Nature Objectives of the Engbertsdijksveen. One of these goals is the recovery of living high moor. In addition to this monitoring well, ...


    By Eijkelkamp Soil & Water

  • Abandoning Monitoring Wells: Safety Issues

    Monitoring wells are typically constructed to gauge the extent of contamination, assess water quality and conduct other hydrogeologic studies. Depending on its objective, the monitoring well may remain in use or may be abandoned permanently. When declared inactive, the well is many a times left as it is. Open unused wells are hazardous to life and environment: • Contamination may spread from one ...

  • Case study - Well monitoring for a water supplier

    The municipality company, in city of Luebek, Germany, provides potable water for approximately 120,000 households, all pumped from more than 30 wells.  These wells have water levels as deep as 160 meters.  The water levels of these groundwater wells must be measured with the highest possible accuracy.  Previously, the pressure probe's analogue output signals (4…20mA) that ...


    By The OTT Hydromet Group

  • Locate buried monitoring wells case study

    A Phase II Environmental Site Investigation was being conducted at a gasoline station in Fort Myers, Florida. In order to minimize costs, our client intended to use several existing on-site monitoring wells rather than installing new wells. However, five of the existing wells had been covered with asphalt and were no longer visible. GeoView was tasked with performing a shallow geophysical study ...


    By GeoView, Inc.

  • Optimal groundwater contamination monitoring using pumping wells

    This study presents a new method for selecting monitoring wells for optimal evaluation of groundwater quality. The basic approach of this work is motivated by difficulties in interpolating groundwater quality from information collected for only few sampled wells. The well selection relies on other existing data relevant to contaminant distribution in the sampling domain, e.g. predictions of ...


    By IWA Publishing

  • Implications of observed and simulated ambient flow in monitoring wells

    The authors of this paper present compelling evidence that conventional monitoring wells act as vertical conduits whenever vertical hydraulic gradients are present (i.e., at most sites). Vertical flow within wells due to natural hydraulic gradients not only makes it impossible to accurately define the vertical distribution of dissolved contaminants within the aquifer, but it can transport ...


    By Solinst Canada Ltd.

  • Use of geostatistics to evaluate the monitoring well network of a TCE plume

    This paper summarises the use of geostatistics to evaluate an existing network of wells in a groundwater monitoring program. The primary objective was to evaluate whether selective well removal would result in a comparable characterisation of a trichloroethylene (TCE) plume. For adequate characterisation, it is important to retain enough wells to evaluate areas with higher concentrations and to ...


    By Inderscience Publishers

  • Plume distortion and apparent attenuation due to concentration averaging in monitoring wells

    This paper, authored by University of Connecticut researchers who performed much of the early work on this topic, describe the various processes that bias groundwater samples collected from conventional monitoring wells. In particular, they discuss the dilution of contaminants that occurs when clean water is simultaneously drawn into monitoring wells pumped to produce groundwater ...


    By Solinst Canada Ltd.

  • A method for reducing purge volumes in deep monitoring wells: a purging experiment.

    Regulatory agencies often require three well casing volumes or more be purged prior to collection of groundwater samples for chemical analysis. Costs are high for testing and disposing of potentially hazardous purge water; therefore, efforts must be made to minimize waste-water volume while obtaining representative groundwater samples. Lockheed sponsored a purge experiment on two deep monitor ...


    By Hargis + Associates Inc

  • San Juan Island well production and tank level monitoring case study

    San Juan Island is a popular resort destination whose population fluctuates with the season and the arrival of Orca whales and salmon runs. To get to the island, you must first drive an hour north of Seattle to the city of Anacortes. From there you take a two-hour ferry ride through a 130 island group to arrive at the 20 mile San Juan Island, which is at the waterway entrance to Puget Sound. Bob ...


    By Mission Communications, LLC

  • Evaluation of the snap sampler for sampling ground water monitoring wells for VOCs and explosives

    A series of laboratory and field studies were conducted to determine the ability of the Snap Sampler to recover representative concentrations of VOC and explosives in ground water. For the laboratory studies, statistical analyses of the data (for each analyte) were conducted to determine if the concentrations of analytes in samples taken with the Snap Sampler were significantly different from ...


    By ProHydro, Inc.

  • Advances in Multilevel Well Technology

    Several detailed field studies performed at research sites in the 1980’s and 1990’s suggest that most contaminant plumes exhibit large variations in concentration over small vertical distances. These variations are caused by spatial variations in the contaminant source zones and heterogeneity of the geologic materials. Conventional monitoring wells have been shown to be ineffective for accurately ...


    By Solinst Canada Ltd.

  • Monitoring Databases

    EHS Data have been providing software and services to our clients to help them manage and report on their Environmental, Health and Safety Data for more than 14 years. This paper deals with the global evolution in environmental concerns and how this changes the data management obligations and requirements of companies. ...


    By EHS Data Limited

  • Well water win-win

    Solve two problems with one filter? That’s what Drinkwell aims to do. Begun through a collaboration between researchers at Lehigh University and the Bengal Engineering and Science University, the Boston-based social venture ...


    By Ensia

  • Extraction well design for DNAPL recovery.

    The potential for downward migration of dense nonaqueous phase liquid (DNAPL) into deeper portions of a saturated hydrogeologic unit has important implications for successful groundwater remediation. Little information has been published regarding the design of extraction wells that allow DNAPL recovery without simultaneously creating a conduit for cross contamination by vertical migration ...


    By Hargis + Associates Inc

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you