municipal wastewater operation Articles

  • Wastewater treatment for a municipality

    Description of the plant At first, wastewater is pre-treated by a combinated sand and fat trap before further treatment is affected by a special screen. The accruing particles are collected in anti-septic plastic bags to avoid any personal contact because of hygienic reasons. Based on the high varying hydraulic amount of wastewater, an aerated mixing and balancing reactor is ...

  • Operational energy performance assessment system of municipal wastewater treatment plants

    Based on the statistical analysis of operational energy consumption and its influential factors from data of 599 Chinese WWTPs in 2006, it is noticed that the most influential factors include treatment technology adopted, treated sewage amount, removed pollutants amount, etc. Using the conclusion above, this paper sets up an integrated system of operational energy performance assessment for ...


    By IWA Publishing

  • Investment and operating costs of municipal wastewater treatment plants in China

    The municipal wastewater treatment will continue to be intensified in China due to the economic development and the poor water quality. Within four years, the number of wastewater treatment plants has doubled. Before 2000, mostly plants without nitrogen and phosphorous removal were built. Since Chinese laws require strict effluent qualities, many plants were built with ...


    By Inderscience Publishers

  • Cellulose recovery from municipal wastewater

    During Aquatech 2015 the Dutch technology developer Brightwork set in the spotlight the recovery of cellulose from waste water. The project Cellulose Assisted Dewatering of Sludge (CADoS) aims at separating cellulose fibres from toilet paper from waste water using finescreening technology. After separation the fibres serve as a filter aid for effective dewatering of biological sludge. The ...

  • Wastewater Treatment Municipality Of Saint-Claude

    In Quebec, the municipalities must make sure that their rejections of sewerachieve the goals applied to the receiving medium. The Rotating BiologicalReactor (RBR), developed by the biological processes division of H2OInnovation, showed its effectiveness during more than one year testingproject, which contribute to the obtaining of the Standard Technology (CF-1) certification allowed by the Quebec ...


    By H2O Innovation

  • Full scale municipal implementations of the Agar IFAS process for municipal wastewater treatment

    Wastewater treatment plant retrofits worldwide are motivated by two main developments: a. Changes in effluent quality regulations, either to more stringent BOD/TSS requirements, or to include nutrient (N and P) removal b. Increase in flows to existing plants, due to either population growth or to expansion of sewerage systems One process capable of giving a cost-effective solution for these two ...

  • Integrated Anaerobic and Aerobic Processes for Treatment of Municipal Wastewater

    ABSTRACTIn this study, integrated anaerobic and aerobic treatment processes for municipal wastewater treatment were investigated for its feasibility to replace the existing conventional activated sludge process. Three types of anaerobic systems − anaerobic sludge blanket, anaerobic sequencing batch reactor and anaerobic filter, as the pretreatment step were studies. High solids and organics ...

  • Municipal Wastewater Pump Station Design Problems and Solutions

    The growth of the Northern Virginia Area around Washington D.C. has resulted in the requirement for numerous new wastewater pumping stations and the upgrade and expansion of existing pump stations. This paper presents practical problems and solutions associated with the following pump station design issues: 1.) Concrete Corrosion Protection, 2.) Corrosion Resistant Materials, 3.) Pump Protection ...

  • Cost Trends of MBR Systems for Municipal Wastewater Treatment

    Cost estimates were developed for full-scale (1 and 5 MGD) MBR facilities designed to treat municipal wastewater. These estimates included both capital and operational / maintenance (O&M) costs related to the headworks, MBR process (biological process and membrane system), chlorine disinfection and effluent storage. The costs associated with the membrane systems were developed from budgetary cost ...

  • Otis, MA municipal wastewater treatment plant information

    Small and rural communities generally find it difficult to assemble the resources to develop a traditional wastewater infrastructure.  Yet, without infrastructure it is difficult to enhance property values and economic development.  Decentralized wastewater treatment systems represent a low cost, low impact and high benefit solution.  Employing modular systems whose processes are ...


    By Aquapoint

  • Stability of alumina, ceria, and silica nanoparticles in municipal wastewater

    Inorganic oxide nanoparticles (NPs) are used in semiconductor manufacturing operations such as wafer chemical–mechanical planarization (CMP). Understanding the stability of NPs in municipal wastewater is essential for the evaluation of the fate of NPs released to municipal wastewater treatment plants (WWTPs). This study aimed to evaluate the stability of Al2O3, CeO2, ...


    By IWA Publishing

  • Municipal Wastewater Treatment - Prichard, Alabama - Case Study

    TenCate  develops and produces materials that function to increase performance, reduce costs, and deliver measurable results by working with our customers to provide advanced solutions. THE CHALLENGE Prichard AL is a town of about 30.000 people north of Mobile. AL Paul David, the Sewer Board Superintendent, oversees the contract management of two (21 ...

  • Treatment of municipal wastewater by membrane bioreactor: a pilot study

    The operational performance of a submerged hollow fibre Membrane Bio-Reactor (MBR) for treatment of municipal wastewater on pilot scale was investigated. The experimental results indicated that the removal efficiency for SS, COD, NH4-N, turbidity, bacterium, iron (Fe2+) and Manganese (Mn2+) was 100%, 94.5%, 98.3%, 99.7%, lg6, 99%, 92.3%, respectively. The water quality of the effluent was quite ...


    By Inderscience Publishers

  • Operating costs for reducing total emission loads of key pollutants in municipal wastewater treatment plants in China

    Total emission load reduction of COD, NH4-N, TN, and TP is the key measure in controlling water pollution and eutrophication. Municipal wastewater treatment plants (MWWTPs) are major contributors in lowering energy consumption and reducing pollutant discharge. The flow-based operating costs have not been directly established to relate to costs of pollutant reduction based on an investigation of ...


    By IWA Publishing

  • Pilot-scale anaerobic submerged membrane bioreactor (AnSMBR) treating municipal wastewater: the fouling phenomenon and long-term operation

    An anaerobic submerged membrane bioreactor (AnSMBR) on pilot-scale treating a mixture composed of municipal wastewater and glucose under mesophilic temperature conditions was operated for 206 days. The performance of the AnSMBR was evaluated at different fluxes, biomass concentrations and gas sparging velocities (GSV). GSV was used to control fouling. In addition, the AnSMBR was operated in ...


    By IWA Publishing

  • Alternate anoxic/aerobic operation for nitrogen removal in a membrane bioreactor for municipal wastewater treatment

    A large pilot-scale membrane bioreactor (MBR) with a conventional denitrification/nitrification scheme for municipal wastewater treatment has been run for one year under two different aeration strategies in the oxidation/nitrification compartment. During the first five months air supply was provided according to the dissolved-oxygen set-point and the system run as a conventional ...


    By IWA Publishing

  • Design and operating experiences of full-scale municipal membrane bioreactors in Japan

    In Japan, membrane bioreactor (MBRs) have been installed in 17 small-scale municipal wastewater treatment plants (WWTPs) in the past 8 years, together with two recently installed MBRs for larger-scale WWTPs. In this study, design and operating data were collected from 17 of them as part of a follow-up survey, and aspects including system design, biological treatment, membrane operation, problems ...


    By IWA Publishing

  • Case study: Municipal WWTP

    OverviewThe municipal WWTP at Monclova, Mexico had to increase its capacity by a factor of 1.5 and improve nitrification capacity, for 100% reuse by industry.  RequirementsThe city of Monclova operates a modern wastewater treatment plant which receives urban and industrial wastewater. A retrofit for an increase of 50% in capacity was required, as well as improvement in ...

  • Structural Fabric Cover Minimizes Odor Emissions for Municipal Wastewater Facility

    As municipal and industrial wastewater facilities find them-selves being ever more tightly squeezed by encroaching neigh-borhoods, the minimization of odor emissions becomes a critical operating issue. This was the problem facing the Municipal Authority of Wyomissing in Reading, Pa., operating a 4 million gallon-perday wastewater treatment facility. Located right within the community, this ...


  • Removal of phthalates and pharmaceuticals from municipal wastewater by graphene adsorption process

    In this work graphene was used for evaluation of its adsorption behavior and performance in removing phthalate esters and pharmaceuticals in municipal wastewater. Di-n-butyl phthalate (DnBP), di-(2-ethylhexyl) phthalate (DEHP), acetaminophen (ACE), caffeine (CAF), cephalexin (CLX), and sulfamethoxazole (SMX) were emerging contaminants (ECs) with detection frequencies over 92% in a one-year ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you