  • Biodiesel Analysis with Mid Infrared - From Feedstock to Fuel

    Introduction The biofuels industry is growing rapidly and so is the need for analysis to ensure quality product. The parameters for quality biodiesel require different types of instruments and measurement systems, such as gas chromatographs (GC), titrators, centrifuges, infrared spectrometers... Although claims are out there for the analyzer that will do it all, unfortunately there is no one ...


    By Spectro Scientific

  • Gas Monitoring for Ventilation Control and Energy Management

    The growing demand for underground and enclosed parking and maintenance garages (resulting from limitations on land availability) has increased the awareness and need for proper ventilation and control systems. In addition, increased health and safety programs have only added to the concerns of toxic and combustible gases in confined or enclosed spaces. Historically, ventilation and make-up air ...


    By Arjay Engineering Ltd.

  • A novel spectrometer design for process and handheld infrared spectral measurements

    Introduction Infrared spectroscopy offers many unique advantages for measurements within an industrial environment. Historically, the technique has been used for a broad range of applications from the composition of gas and liquid mixtures to the analysis of trace components for gas purity analysis. In cases where a well-defined method of analysis is involved, such as the measurement of ...


    By CIC Photonics, Inc.

  • A Comparison of Point Sensors and Open Path Monitors For Toxic Gas (esp. HF) Monitoring

    Point Sensors Ion Mobility Spectroscope (IMS) – a gas sample is ionized by a radioactive source (Ni63). Differences in ion drift under the influence of an applied electric field produce a spectrum that is dependent on the mass, charge, and shape of the component ions. The detector signal and strength is tuned to the drift time of the ion of interest (in this case HF) and signal strength is ...


    By Boreal Laser Inc.

  • Comparing TGA, FTIR and fixed filter infrared analyzers for measuring soot levels in in-service lubricants

    Measuring soot in diesel engine oil has become more important as soot levels get higher due to exhaust gas recirculation. As soot isone of the key indicators for the condition of the oil, diesel engine maintenance programs performing regular soot checks can realize cost savings by extending drain periods and reducing used oil disposal. TGA (Thermal Gravimetric Analysis) is the traditional method ...


    By Spectro Scientific

  • Understanding the Benefits of Fixed Gas Detection

    "Fixed gas detection is an essential method of ensuring maximum protection for personnel and plant. There are a variety of technologies available for a multitude of applications. Understanding fixed gas detection is the first step in providing safety." What is fixed gas detection? Fixed gas detection is installed with the aim of providing continuous, area and personnel protection. ...


    By a1-cbiss

  • Selecting and Placing Gas Detectors for Maximum Application Protection

    Many industrial processes involve dangerous gases and vapors: flammable, toxic, or both. With the different sensing technologies available, and the wide range of industrial applications that exist, selecting the best sensor and locating them properly for the job at hand can be a challenge. To ensure a high level of safety, know the latest sensing technologies, which technology is best for the ...

  • Detecting Hydrogen Gas and Fires: Seeing the Unseen

    Hydrogen usage is growing. The general public sees and reads about hydrogen as an alternative fuel for cars. However, the big use for hydrogen is found in hydrocarbon processing and other important manufacturing processes. Hydrogen is the first element on the periodic table and is an essential element in the manufacturing of many of our everyday products. We must have respect for its explosive ...

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By Environnement S.A

  • Safety Systems Depend on Reliable Field Sensors (Emphasis on Fire and Gas Detectors)

    Abstract Because not all hazards are the same, identifying and quantifying the hazard is the starting point in choosing sensing technology. Not all detectors are the same, and they should be selected according to their ability to detect the hazard. This paper gives a broad summary of technologies that provide users reliable responses to hazardous conditions, that minimise false ...

  • The Pitfalls of Process TOC analysis and how to avoid them case study

    Since the introduction of Total Organic Carbon (TOC) Analyzers by Dow, Union Carbide and Automated Environmental Systems in thel960,s,l-5\ they have proven to be an invaluable tool in the environmental and process monitoring fields. While technologies have advanced since then, certain performance characteristics required for true process control have been notably absent. The purpose of this paper ...


    By TOC Systems, Inc.

  • Detecting Gases: What You Can`t Smell Can Hurt You

    Walking through a drill-site area, a worker smells rotten eggs and stops tor a minute or two to assess where a gas leak might exist. Rubbing his itchv eves as he investigates further, he notices that he no longer smells the tell¬tale hydrogen sulphide odour. He does not realize that the gas has deadened his olfactory senses and unless he leaves the area within seconds, he could lose ...

  • Detection and measurement of GWGs in semiconductor fab facilities

    Problem Statement Various processes and tools in the modern wafer fab plant produce effluent streams that contain unacceptably high levels of perfluorocarbon GWGs (greenhouse warming gases). These effluent streams are abated by plasma incineration and wet scrubbers and other techniques. It is necessary to measure the destruction removal efficiency (DRE) of the various abatement methods ...


    By CIC Photonics, Inc.

  • Mobile Stationary Source Emissions Testing, Coming to a Facility Near You?

    Last week, Antea Group had the unique opportunity to perform a RATA (relative accuracy test audit) of the emissions from a thermal oxidizer at an ethanol production facility located in Minnesota using a state-of-the-art mobile testing laboratory. During this RATA audit, actual stack emissions levels (including NOx, SOx, CO2, CO, O2, flow rate, temperature, velocity and pressure) from the ...


    By Antea Group - USA

  • Case study - TPH Oil & Grease applications

    These case studies illustrate the performance generated from customers who have used Sitelab’s UVF-3100 analyzer for testing total petroleum hydrocarbons in the C10 to C50 range. Sitelab’s TPH-Oil calibration kit is designed to correlate well to laboratory “Oil and Grease” test methods. This includes EPA Methods 1664 and 9071B by Gravimetric, EPA Method 418.1 by Infrared ...


    By Sitelab Corporation

  • Smart LDAR — more cost-effective?

    On December 19, 2008, EPA issued a final rule establishing a voluntary Alternative Work Practice (AWP) to detect leaks of volatile organic compounds (VOC) and hazardous air pollutants (HAP) from process equipment (FR Vol. 73, Number 246), thereby providing the regulated community additional flexibility in complying with leak detection and repair (LDAR) requirements. The AWP allows owners or ...


    By Trinity Consultants

  • Methane emission estimates using chamber and tracer release experiments for a municipal waste water treatment plant

    This study presents two methods for estimating methane emissions from a waste water treatment plant (WWTP) along with results from a measurement campaign at a WWTP in Valence, France. These methods, chamber measurements and tracer release, rely on Fourier transform infrared spectroscopy and cavity ring-down spectroscopy instruments. We show that the tracer release method is suitable for ...


    By Ecotech Pty Ltd

  • Professional Pest Manager Magazine

    In the last issue of Professional Pest Manager (PPM), we talked with western Sydney based pest manager, Greg Morrison, about his use of the Green Eye Termite Monitoring and Baiting Station. For this issue, we tracked down Greg, who operates Antibug Pest Control and his senior technician, Robert Guiffre, checking out a job which both men reckoned had become a major headache. The good news was that ...

  • Valve actuation and control in the modern refinery

    Introduction The Reliance refinery at Jamnagar in India is one of the largest single refinery sites in the world and virtually all of its valves are motorised with Rotork actuators. Almost 3000 Rotork IQ intelligent valve actuators were installed during the construction of the original refinery, tank farm and power station in the late 1990s, together with a Rotork Pakscan 2E two-wire ...


    By Rotork