non-dispersive infrared analyzer Articles

  • What is a Spectrometer?

    The characteristics of a white LED light differs greatly, when compared to a yellow CFL. Without any special tools, one can see that the LED emits a clear white color, while the CFL generates yellow light. Going one step further, using a spectrometer, one will be able to “dissect” the light sources and see that they are composed of other colors in the visible light spectrum, such as ...


    By Larson Electronics LLC

  • Comply with Highly Regulated Oil in Water Measurements Using Portable Infrared Analyzers

    The Petroleum Industry – both offshore and onshore -- has regulations that limit the amount of oil in discharged water.  Fixed filter infrared (IR) analyzers have been used to test oil levels in produced water on drilling platforms for over 45 years for a number of reasons. On oil rigs where real estate is at a premium, infrared analyzers such as the Wilks InfraCal TOG/TPH ...


    By Spectro Scientific

  • Mid-infrared analysis of biodiesel

    The biodiesel industry is growing rapidly. and so is the need for analysis 10 ensure quality product and keep biodiesel in good standing. Biodiesellhat has residual glycerin, glycer· ides, or inorganic salts from the production process can cause problems such as Iilter plugging and injector coking in a diesel engine. The biodiesel blend ralio also can affect cold weather performance, lax ...


    By Spectro Scientific

  • Portable Infrared Analyzers Provide On-Site Measurement of Oil and Grease Levels in Hydraulic Fracturing Water

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well.  Whether the water is going to be taken off-site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the water.  Waiting for remote laboratory results to determine the oil level can take several ...


    By Spectro Scientific

  • Comparing TGA, FTIR and fixed filter infrared analyzers for measuring soot levels in in-service lubricants

    Measuring soot in diesel engine oil has become more important as soot levels get higher due to exhaust gas recirculation. As soot isone of the key indicators for the condition of the oil, diesel engine maintenance programs performing regular soot checks can realize cost savings by extending drain periods and reducing used oil disposal. TGA (Thermal Gravimetric Analysis) is the traditional method ...


    By Spectro Scientific

  • Biodiesel Analysis with Mid Infrared - From Feedstock to Fuel

    Introduction The biofuels industry is growing rapidly and so is the need for analysis to ensure quality product. The parameters for quality biodiesel require different types of instruments and measurement systems, such as gas chromatographs (GC), titrators, centrifuges, infrared spectrometers... Although claims are out there for the analyzer that will do it all, unfortunately there is no one ...


    By Spectro Scientific

  • Upgrading from Pellistor Gas Sensors to Infrared Technology

    In this article Andy Avenell, Crowcon’s Fixed Systems Product Manager, considers the shift towards infrared (IR) gas sensor technology in the oil and gas industry. Abstract Flammable gases and vapours can present considerable dangers in many industrial applications, none more so than the processes involved in extracting, transporting and processing oil and gas. Fast and reliable ...

  • A novel spectrometer design for process and handheld infrared spectral measurements

    Introduction Infrared spectroscopy offers many unique advantages for measurements within an industrial environment. Historically, the technique has been used for a broad range of applications from the composition of gas and liquid mixtures to the analysis of trace components for gas purity analysis. In cases where a well-defined method of analysis is involved, such as the measurement of ...


    By CIC Photonics, Inc.

  • Get Comparable ASTM/EN Data for Biodiesel Blend Measurements While Saving Time and Money using Portable IR Analyzers

    Both EN 14078 and ASTM D7371 methods for measuring the percent biodiesel in diesel fuel use infrared analysis as the analytical method and are based around using an FTIR spectrometer which has the capability to do a multitude of analyses besides the biodiesel in diesel measurement. This is great for a laboratory where various biofuels measurements are required. However, if the only measurement ...


    By Spectro Scientific

  • Portable IR Analyzer Provides ASTM Field Test Method for Measuring Soot Levels In Diesel Engine Lubricating Oils

    The InfraCal Soot Meter, from Wilks Enterprise, gives users an approved ASTM testing method for measuring the percent level of soot in diesel engine lubricating oils -- ASTM Method D7686-2011 entitled “Test Method for Field-Based Condition Monitoring of Soot in In-Service Lubricants Using a Fixed-Filter Infrared (IR) instrument.” While there is widespread disagreement on used-diesel ...


    By Spectro Scientific

  • On-Site TPH in Soil Measurements in less than 15 Minutes with Portable IR Analyzers

    On-site analysis of total petroleum hydrocarbon (TPH) concentration levels in soil are easily handled using the InfraCal TOG/TPH Analyzers manufactured by Wilks Enterprise, Inc.  The InfraCal TOG/TPH Analyzers are portable infrared (IR) analyzers that quickly determine TPH levels in less than 10-15 minutes, including the extraction.  Concentrations as low as 10 ppm to well over 10,000 - ...


    By Spectro Scientific

  • Case study - Cost-saving solutions using Sievers InnovOx TOC analyzers - optimizing organic loading

    Cost Concern  A company’s inability to recognize real-time organic loading changes in their wastewater treatment plant could result in excessive charges from the local water utility. Company Challenge A production facility located in the U.S. Midwest currently controls the organic loading in their wastewater’s chemical treatment ...


    By GE Analytical Instruments

  • GE Leakwise Application Notes: Oil Sheen Detection -- An Alternative to On-Line PPM Analyzers

    Introduction Discharge of hydrocarbons in industrial water is restricted by environmental authorities in most countries to a few parts per million (ppm). Environmental authorities currently monitor wastewater, stormwater, and cooling water discharges from ...


    By GE Analytical Instruments

  • TOC Analysis for Standard Methods 5310B: High-Temperature Combustion Method

    Introduction Total Organic Carbon (TOC) is a rapid method that analyzes for organic carbon and expresses the result as the amount of carbon found. It is a non-specific method unable to distinguish between various organic species and only indicates that organic carbon compounds are present. Organic carbon analyzers operate by the determination of the amount of total carbon present in a ...

  • Measuring IR Light and Near-IR Light

    Infrared (IR) light emits a broad range of non-visible wavelengths in the electromagnetic spectrum. Applications for infrared, including near-infrared, are defined by the respective IR bands during output. For example, LIDAR (Light Detection and Ranging) equipment uses 1,000 nm and 1,550 nm IR bands while surveying an area. In the military sector, 850 nm, 1,060 nm and 1,500 nm (and up) are used ...


    By Larson Electronics LLC

  • The Pitfalls of Process TOC analysis and how to avoid them case study

    Since the introduction of Total Organic Carbon (TOC) Analyzers by Dow, Union Carbide and Automated Environmental Systems in thel960,s,l-5\ they have proven to be an invaluable tool in the environmental and process monitoring fields. While technologies have advanced since then, certain performance characteristics required for true process control have been notably absent. The purpose of this paper ...


    By TOC Systems, Inc.

  • Oil in frac water testing

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well. Whether the water is going to be taken off site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the wa-ter. Waiting for remote laboratory results can take several days to a week. The InfraCal TOG/TPH ...


    By Spectro Scientific

  • Mercury sorption by silica/carbon nanotubes and silica/activated carbon: a comparison study

    Nanocomposites of silica incorporated with carbon nanotubes (silica/CNT) and activated carbon (silica/AC) were synthesized and characterized by scanning electron microscopy (SEM), element mapping, energy dispersive X-ray spectroscopy (EDX), thermogravimetric analyzer (TGA) and Fourier transform infrared spectroscopy (FTIR). Silica/CNT and silica/AC were investigated for efficient removal of ...


    By IWA Publishing

  • New White Paper features Solvents for Oil and Grease in Water Measurements

    A White Paper entitled, “Solvent Choices for Infrared Testing of Oil and Grease in Water” was recently published by Wilks Enterprise, Inc.  Infrared (IR) analysis is widely used worldwide for determining the amount of oil and grease in water as it is a cost-effective measurement technique that can be easily done on-site or in a laboratory.  Since water is a strong absorber ...


    By Spectro Scientific

  • Online analysis of TOC, TNb, TP, and COD in water

    The control of waste water treatment plants is of special importance - from an ecological as well as economic point of view. The most common water parameters for controlling and optimization are the total organic carbon (TOC), chemical oxygen demand (COD), total nitrogen bound ( ...


    By LAR Process Analysers AG

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you