odor measurement Articles

  • Nitrogen Demand Increases for Semiconductor: How Safe Are You?

    As users demand ever-smaller smartphones and better televisions, semiconductor manufacturing plants are tasked with developing new products faster and using new materials. Key to the continued success of the semiconductor industry are inert gases, which include nitrogen and argon. When used safely, both nitrogen and argon play a number of important roles within the semiconductor ...

  • Biosolids Odor Prediction Models: Sensory and Analytical Measurement Approaches

     Abstract Practical biosolids odor prediction models were developed to be use by managers for predicting the odor emission rates of biosolids generated daily at the District of Columbia’s wastewater treatment plant. These models evaluated daily wastewater treatment process data and predicted the expected biosolids odor emissions levels prior to recycling of this material on land. ...

  • Canarina DISPER software · measuring odor concentration · commands 6

    In the center of the program window, we will draw and we will calculate the different polluting processes. We can draw using two different planes: parallel to the land surface (XY) and perpendicular to the land surface (XZ). There is a grid in the XY-plane. The coordinate origin is on the left bottom corner (X=0, Y=0) in XY-planes (parallel to the land surface). In addition, the coordinate origin ...

  • Development of a novel odor measurement system using gas chromatography

    This paper describes a novel odor measurement system for creating arrays of virtual chemical sensors with nonoverlapping responses using ultrahigh-speed gas chromatography with a surface acoustic wave sensor (GC/SAW). This GC/SAW system provides high-resolution twodimensional olfactory images for easy recognition of many complex odors. Separation and quantification of the individual chemicals ...

  • Landfill Closure - Odor Control

    Products & Equipment Used: Pneumatic Foam Unit 1600/40 AC-645 Long Duration Foam AC-904 Long Duration Foam Application summary: The Michigan Department of Natural Resources required an emissions control measure during the closure of an Ann Arbor Solid Waste Landfill cell. The odors that were emanating from the landfill during ...


    By Rusmar Inc.

  • Reducing Odor and VOC Emissions

    The Montgomery County Regional Composting Facility (MCRCF) in Silver Spring, Maryland is designed to process 400 wet tons/day of lime amended biosolids from the Blue Plains Wastewater Treatment Plant (WWTP) in Washington, D.C. Recently, political pressures forced operations to cease at the MCRCF. Although the aerated static pile composting plant’s fate has not been completely decided, its owner, ...


    By BioCycle Magazine

  • Smart Series-Odor Management

    Tackling odors at composting facilities is a manageable task made simpler by inventorying and treating all sources and tapping into technology advances. Perhaps one of the most difficult realities that had to be faced 15 to 20 years ago by the composting universe is that the phrase, “odor-free” - at least when it comes to composting - is probably an oxymoron. Feedstocks that biodegrade within the ...


    By BioCycle Magazine

  • No more odor and corrosion case study

    Sewer systems are vulnerable to corrosion and, at times, can be the source of unpleasant odors. Kemira’s new H2S-Guard tackles both problems, as in most cases the source of these issues is hydrogen sulphide, forming in septic areas, in other words areas where no oxygen for metabolic reactions is available. The H2S-solution combines three important steps: measurement, monitoring and control ...

  • Odor Control Advances at Composting Facility

    The Rockland County (New York) Cocomposting Facility began operations in February, 1999, processing biosolids from the five publicly owned treatment works (POTWs) in the county. The Rockland County Solid Waste Management Authority (RCSWMA) owns the facility, but contracted with Waste Management of New York to design, build and operate (DBO) the 110 wet tons/day agitated bin composting facility ...


    By BioCycle Magazine

  • Online Odors Monitoring in Waste Water Treatment Plants

    Odors are very distinct air contaminants as they generate nuisances (see note at the end). The factors playing a role in the determination of odor annoyance are : odor concentration and intensity, frequency, appreciation, duration, synergy and location. Chromatotec proposes an automated solution to well identify the origin and the level of odors. Technology Description We offer a ...


    By Chromatotec Group

  • Biotreatment of Odors from the Zimpro Sludge Conditioning Process

    Management of odor emissions generated during thermal sludge conditioning is a well known disadvantage of the “Zimpro” process. Traditional methods of using chemical oxidation and high temperature destruction result in the formation of secondary products, such as chlorine gas, organic halocarbons or nitrogen oxides. In this study, biotrickling filter technology was evaluated at the Villa Hills ...


    By PRD Tech, Inc.

  • Dispersion Modeling as a Tool to Establish Odor Policy

    Odor control is a critical component of the Orange County Sanitation District’s (the Sanitation District) planning and operations. The Sanitation District’s two wastewater treatment plants (Fountain Valley, CA and Huntington Beach, CA) were isolated when originally constructed in the middle of the 20th century, but are now surrounded by high-density residential areas as well as highly used ...

  • Treatment of unpleasant odors in municipal wastewater treatment plants

    The purpose of this paper to present a case study on how to address the odor problem from secondary sources within a municipal wastewater treatment plant (WWTP) by first identifying the locations of the problem and second by evaluating alternative treatment technologies. The WWTP of Chania is a typical 100,000 equivalent inhabitants-facility in a warm semi-arid environment which is located close ...


    By IWA Publishing

  • Mariposa compost facility odor remediation update

    Staring in the winter of 2006 the staff at the Mariposa Compost Facility worked quickly to make process changes to bring odor issues under control. Here is the latest chapter in their story. Odor (incident) Logs In January 2007 the Local Environmental Agency (LEA) provided "odor logs" to the county residents that were troubled by the compost facility's odors. The odor logs were ...


    By Engineered Compost Systems

  • Controlling Odors from Waste Water Treatment Plants

    INTRODUCTION In recent years, there is growing public awareness of odors from waste water treatment plants, which mainly stems from the following observed trends: The public is less tolerant of objectionable odors from waste water treatment plants; Many waste water treatment plants have seen residential, commercial, or other developments established near the facility ...


    By PRD Tech, Inc.

  • Wastewater-Solids Dewatering Odor Control - Case Study

    Background The Milan Wastewater Treatment Plant, located just south of Moline, Illinois, is a 1.7 MGD (6,434 m3/day) activated sludge facility with an average wastewater flow of 700,000 gpd to 800,000 gpd. This facility dewaters primary sludge using a belt filter press (Figure 1). The press operates an average of three times per month, 8 hours per day at a pump rate of 100 gpm. The ...


    By Carus Corporation

  • Fitting Into the Neighborhood: Operating by Progressive Odor Management Plan

     Operating by Progressive Odor Management Plan Why would anyone build an $11 million composting facility designed to process an average of 130 tons/day of feedstocks less than one mile from luxury homes, a new high school, a golf course, fast food restaurants, a grocery store, and in an area with a vivid memory of a compost site that impacted the neighborhood and shut down due to odor ...


    By BioCycle Magazine

  • Food Processing: Odor Control in Edible Oil Processing

    Abstract: The problems with odor around a typical edible oil deodorizer are discussed in detail, and a three-step solution to eliminate these problems is presented. The three steps are a distillate recovery system which recovers most of the fatty acid in the deodorizer vapor discharge as a valuable byproduct, a closed loop barometric cooling water system which keeps the fatladen ...


    By CR Clean Air Group, LLC

  • Comparison of two standard odor intensity evaluation methods for odor problems in air or water

    Government agencies responsible for ensuring healthful water and/or air quality are often faced with resolving public complaints of nuisance odors. Understanding variations in odor intensity may ultimately lead to the establishment and application by such agencies of quantitative limits for effective odorant control. An odor panel was trained in suprathreshold odor intensity evaluation using ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you