  • Reduction of odor and odorant emissions from slurry stores by means of straw covers

    Swine (Sus scrofa) slurry stored in open storages is a source of airborne contaminants. A customary practice for ammonia and odor control consists of covering the surface of the slurry with floating materials, such as straw. Although straw covers have been proven to generally reduce gaseous emissions, more knowledge is needed regarding how age, moisture content, and microbiological development of ...

  • Application of Biotrickling Filter for Odor Control at The Morris Forman Wastewater Treatment Plant

    Pilot-scale study of a biotrickling filter using synthetic, high surface area media was undertaken by MSD Louisville, with the intention of saving the high cost of operating thermal oxidizers. Currently, two recuperative thermal oxidizers are used to treat odorous emissions from various sources. The pilot study showed that it is possible to treat hydrogen sulfide and organic sulfur compounds at ...


    By PRD Tech, Inc.

  • Reduction of chlorinous odor by the combination of oxidation and ion-exchange treatments

    To better control chlorinous odor in tap water, we assessed the performance of the combination of oxidation (ozonation or advanced oxidation processes, AOP) and ion-exchange treatment. In this process, the hydrophilic neutral fraction (a major dissolved organic matter (DOM) fraction) is converted to ionic species, and these ions and ammonium ion are effectively removed during ion-exchange ...


    By IWA Publishing

  • Control of biosolids cake odors using the new biosolids odor reduction selector process

    ABSTRACT Recent introduction of more efficient dewatering devices that generate higher solids concentrations in dewatered cake has been plagued with the non-desirable side effect of more odorous dewatered biosolids. Previous research has shown that the production of volatile organic sulfur compounds (VOSC’s) such as methanethiol (MT), dimethyl sulfide (DMS), and dimethyl disulfide (DMDS) ...

  • Advancing Odor Control to New Levels Gurnee Sewage Treament Plant North Shore Sanitary District

    ABSTRACTThe North Shore Sanitary District (District) owns and operates a 24-mgd sewage treatment plant located in Gurnee, Illinois. Frequently, odors from the two-stage activated sludge plant’s solids handling facilities made their way into the adjacent residential neighborhood. A new two-stage odor control system for the plant’s solids handling facility was put on-line in October 1999. This ...

  • Managing Ponds for BOD Reduction and Odor Control

    A large number of food processors utilize ponds to treat their wastewater. Most of the time these ponds are aerobic in which they use oxygen to degrade the wastewater biological oxygen demand (BOD). Fruit and vegetables contain a high amount of simple sugars and other organic compounds that when exposed to water are released into the water stream. These organic compounds require oxygen to degrade ...


    By Integrated Engineers Inc.

  • Diesel Oxidation Catalyst for Locomotive

    Description A tourist touring train in Skagway, Alaska, powered by a 6 cylinder, 900 hp, Alco 251B diesel locomotive. The train carries tourists through a scenic mountain area. Challenge Diesel odor and soot from the diesel locomotive was a nuisance to passengers on the train. DCL was approached for an emission control solution. Solution DCL custom designed an ...


    By DCL International Inc.

  • Case Study: Georgia wastewater utility credits Ecosorb for significant reduction in odor complaints

    The Douglasville-Douglas County Water and Sewer Authority (WSA) has been delivering quality water and wastewater service to more than 90,000 Douglas County residents for over 17 years. WSA's slogan "Award-Winning Service For Our Local Community," proves to be much more than just advertising jargon. Over the past 17 years, their honors have included three citations from the U.S. Environmental ...


    By OMI Industries (OMI)

  • Southeast Georgia sewage treatment

    Problem: A WWTP in Southeast Georgia located on a resort island has a 3 million gallon per day flow. The WWTP was experiencing major odor problems at the head of the plant, as well as poor digestion and settling of bio-solids in the SBR’s and aerobic digesters. The odors were primarily H2S and were the source of numerous complaints from the residents living in the vicinity of the WWTP. The plant ...


    By BluePlanet Labs

  • Case study of odor and indoor air quality assessment in the dewatering building at the Stickney Water Reclamation Plant

    Indoor air quality (IAQ) and odors were determined using sampling/monitoring, measurement, and modeling methods in a large dewatering building at a very large water reclamation plant. The ultimate goal was to determine control strategies to reduce the sensory impacts on the workforce and achieve odor reduction within the building. Study approaches included: (1) investigation of air mixing by ...


    By IWA Publishing

  • Real-time monitoring and forecasting of odor after dewatering in wastewater treatment

    A real-time odor monitoring system was developed to evaluate and predict odors levels of dewatered solids generated by the District of Columbia Water and Sewer Authority’s (DCWASA) advanced 370 mgd wastewater treatment plant (WWTP) in Washington, DC. Each year, DCWASA generates over 400,000 wet tons of biosolids and recycles these biosolids by applying them to over 20,000 acres of agricultural ...

  • Case Study - Georgia wastewater utility credits Ecosorb for significant reduction in odor complaints.

    The Douglasville-Douglas County Water and Sewer Authority (WSA) has been delivering quality water and wastewater service to more than 90,000 Douglas County residents for over 17 years. WSA’s slogan “Award-Winning Service For Our Local Community,” proves to be much more than just advertising jargon. Over the past 17 years, their honors have included three citations from the U.S. ...


    By OMI Industries (OMI)

  • Biotreatment of Odors from the Zimpro Sludge Conditioning Process

    Management of odor emissions generated during thermal sludge conditioning is a well known disadvantage of the “Zimpro” process. Traditional methods of using chemical oxidation and high temperature destruction result in the formation of secondary products, such as chlorine gas, organic halocarbons or nitrogen oxides. In this study, biotrickling filter technology was evaluated at the Villa Hills ...


    By PRD Tech, Inc.

  • Full-scale field trials identify sulfate discharge limits for municipal wastewater odor and corrosion control

    ABSTRACT The Massachusetts Water Resources Authority (MWRA) owns and operates one of the largest wastewater collection and treatment systems in the U.S. serving 45 member communities and operating the 1.2 billion gallon-per-day Deer Island Wastewater Treatment Plant in Boston Harbor. The MWRA has very few odor and corrosion problems so it was unusual when the MWRA encountered a high ...

  • Missouri city wastewater treatment plant case study

    Project Summary Missouri City selected In-Pipe Technology, Inc. to provide a collection system bioaugmentation program reduce influent load, energy costs and sludge production at the wastewater treatment plant (WWTP). The program is also designed to control fats, oil and grease (FOG) accumulation and odor in the collection system. In-Pipe Treatment Strategy ...

  • Treatment of unpleasant odors in municipal wastewater treatment plants

    The purpose of this paper to present a case study on how to address the odor problem from secondary sources within a municipal wastewater treatment plant (WWTP) by first identifying the locations of the problem and second by evaluating alternative treatment technologies. The WWTP of Chania is a typical 100,000 equivalent inhabitants-facility in a warm semi-arid environment which is located close ...


    By IWA Publishing

  • Smell and odor nuisance, what is that?

    As Aerox we offer our clients sustainable solutions for the reduction of industrial odor emissions. In the conversations we have with our contacts we often receive questions about how this exactly works, what smell actually is, why something stinks and why we actually are in this market. Hence it is interesting to consider what odor and odor nuisance actually are. In this article we have ...


    By Aerox B.V.

  • Pearl river valley water supply district case study

    Performance History and Discussion In-Pipe Technology implemented the first phase of a collection system Professional Services Program in 2001. Beginning in 2002, additional collection system basins were added to the services program. Currently, the treated areas include the North and South shore of the Pelahatchie Bay, the Main Harbor, and two Lagoon Waste Water Treatment Plant (WWTP) ...

  • Q-PAC® supports biological growth for BOD reduction

    Patented Bioreactor uses Q-PAC Randomly Packed Media in Application of Specific Bacterial Cultures for Treating High Strength Industrial Waste for BOD and Odor Reduction in a Cheese Manufacturing Plant A cheese manufacturer in Upstate New York with one three million gallon lagoon is testing a bioreactor (TVTBIO 32) from TVT US Corporation. The concept is essentially the same as bacteria eating ...


    By Lantec Products, Inc.

  • A combined process of non-thermal plasma with sludge stabilization for the simultaneous reduction of odor and organic waste

    Odor emissions and sludge disposals have become most challenging issues in many sludge treatment plants, and separate chemical oxidation processes have been commonly employed for these problems. It is, therefore, necessary to develop a combined process that simultaneously reduces the odor emissions and the amount of waste sludge. In this study, a non-thermal plasma reactor using a dielectric ...


    By IWA Publishing