oily waste Articles

  • Treatment of Oily-Waste Process Streams

    Standard oily-wastewater remediation relies on API 650 for oily-wastewater separation (O/W/S) treatment using gravimetric lagoon separation, then reprocessing the recovered floatable slop oil, followed by chemical flocculation, then reprocessing the recovered oily sludge, followed by dissolved air flotation (DAF), then using holdingpond clarification of supernatant wastewater, before ...


  • Oily waste disposal case study

    The data shows that the total pounds of oil on the land farm has gradually increased from October 1983 through to March 1988. Our products were added one month later, April 1988. The graph shows that despite adverse conditions, including a dry and hot summer, the land farm degraded almost ten times the oil it had in previous years using our ...

  • Oily Water Separators

    Mining Water Treatment & Water Recycling H2O Cleanawater has worked with Australia's mining companies for over 16 years providing waste water treatment and water recycling solutions for wash down, workshop and refuelling area applications. Oil Separators that are Pre-Plumbed and Pre-Wired ...


    By Cleanawater

  • Skimming Oily Wastewater

    As large generators of oily wastewater tighten effluent controls, the U.S. Environmental Protection Agency (EPA) is targeting smaller generators. Some of the firms receiving their attention are smaller manufacturing plants, automotive garages, mobile equipment service shops and truck farms. Many of these firms do not have access to a sanitary sewer system that will accept oily wastewater. Because ...


    By Abanaki Corporation

  • Eco-toxicity of oily wastes containing TENORM

    Oily wastes are considered as one of the most hazardous waste types. Additionally to petroleum components, they can contain radioactive elements. This study aimed to estimate the toxicity of four raw and two treated waste samples obtained from petroleum production yard. Eight elutriate bioassays using plants ( Raphanus sativus and algae Scenedesmus quadricauda ), crustacean ...


    By Inderscience Publishers

  • Hazardous Oily Water Treatment Facility

    Wastewater Treatment Success Stories Hazardous Oily Industrial Waste Water Treatment The sample was received was at a pH of 6.8 and did not require any pH adjustment. 100 ml of the sample was tested and dosed with 0.4 ...


    By Integrated Engineers Inc.

  • On Site Bioremediation Of Oily Ballast Waters Of Ships and Tankers

    A poster presentation was made at the International Ballast Water symposium held in London, UK Paper discusses application of bioremediation products for ship board remediation of oily ballast water on ships and tankers and presents some case studies on bioremediation of industrial oily waste. Abstract Discharge of oily wasie ballast waier is a perpetual problem for most types of ...


    By Sarva Bio Remed, LLC

  • Separation and recovery of oil from oily waste materials using anaerobic thermal desrotpion unit technology

    RLC Technologies, Inc.’s Anaerobic Thermal Desorption Unit (ATDU) is an exsitu, non-incineration technology designed to separate hydrocarbons from various matrices including oilfield waste, soil, sludge, sand, filter-cake, tank and tanker bottoms, organic-based hazardous waste and contaminated soil in a non-oxidizing atmosphere without destroying the hydrocarbons. This paper briefly ...


    By RLC Technologies, Inc.

  • Oily Wastewater Processing Facility Wastewater Treatment Case Study

    Impressive Oil Water Separation This is the result of our Floccin 1105 product treating a sample from an oily wastewater treatment facility. As you can see, the Floccin 1105 was very effective at clarifying the waste as well as capturing all of the oil. These results were achieved with no pH adjustment and minimal Floccin addition (~ 1g/1000ml). The client is going to purchase and ...


    By Integrated Engineers Inc.

  • Comparative applications of bioreactor and shake-flask systems in the laboratory treatment of oily sludge

    This study investigates the remediation efficiencies of a locally fabricated bioreactor system and a shake-flask system, using samples of oily sludge with varying concentrations of NPK fertiliser. Hydrocarbon removal efficiency of 46% and 24.2% was recorded for the stirred slurries containing 15- and 0-g NPK, respectively, in the bioreactor; whereas values of 40.1%, 33.2% and 18.9%, respectively, ...


    By Inderscience Publishers

  • Skimmer with rolling stand helps prevent oily water discharge

    Despite continuous replacement and upgrading of fittings, it is difficult to entirely eliminate hydraulic and lubricating oil coming from machines during normal operations and maintenance activities. This oil ends up in different pits used to collect wastewater throughout the plant. Because of high oil content, city officials would not allow plant wastewater to enter the Longmont sanitary sewer ...


    By Abanaki Corporation

  • Anaerobic Co-Digestion of a Single Source Oily Waste and High Strength Pet Food Wastewater: A Study of Failure and Revival of a Full Scale Digester

    ABSTRACTThis paper focuses on the revival of a formerly failed digester of 1800 m3 volume. The most obvious cause of failure was identified to be due to capping caused by foam and scum, as result of attempting to treat oil rich, high strength wastewater. The revival was affected by implementing co-digestion in a 3-step remedial procedure. Though in the typical sense, codigestion involves separate ...

  • On-Site Bioremediation Of Oily Waters At The Maintenance Facility Of South Jersey Port Corporation, Camden, NJ

    Water from the maintenance shop in South Jersey Port Corporation in New Jersey was contaminated with free oil and grime during pressure washing of port vehicles. The shop would wash at least four vehicles in a day. Wash water was released through an oil water separator system using absorbent socks and diapers to absorb the oil before release into the waste stream as per the directive of the local ...


    By Sarva Bio Remed, LLC

  • VSEP`s low operating cost and superior performance provide a high-tech alternative for oily wastewater processing

    A unique membrane filtration system has been installed at several major waste oil hauling operations and manufacturing plants that handle or produce oily wastewater. The system manufactured by New Logic, of Emeryville California near San Francisco, is also being used to process used crankcase waste oil and produce filtrate that can be sold as a higher value bunker oil. The V✧SEP, ...


    By New Logic Research, Inc.

  • Biosurfactants as demulsifying agents for oil recovery from oily sludge – performance evaluation

    The oil producing and petroleum refining industries dispose of a significant amount of oily sludge annually. The sludge typically contains a mixture of oil, water and solid particles in the form of complex slurry. The oil in the waste sludge is inextractible due to the complex composition and complex interactions in the sludge matrix. The sludge is disposed of on land or into surface water ...


    By IWA Publishing

  • Bahamas Diesel Steam Power Plant Oily Wastewater Emulsion Treatment Case Study

    Oily Wastewater Treatment at a Bahamas Power Plant Diesel Steam Power Plant Oily Wastewater Emulsion Diesel/Steam Power Plant Oily/Water Emulsion - The waste water is from the operations of a steam ...


    By Integrated Engineers Inc.

  • Waste Minimisation Strategy: Monroe Australia

     The company has implemented a major waste minimisation strategy that has enabled it to process liquid waste, reduce water usage, reduce chemical and waste disposal costs, and eliminate pollution. It installed new equipment which treats wastewater to remove emulsified fats and oils, grease, heavy metals and all forms of suspended, colloidal and some dissolved solids. Mains water usage has ...


  • Incorporation of petroleum waste in clay ceramics and its characterisation

    In Brazil, the growth of the petroleum industry has resulted in an increasing amount of toxic oily wastes that have a high environmental impact. This work analyses the possibility of recovering waste from the petroleum industry using the powder technology route to produce clay-based ceramics. Batches of clay-petroleum waste mixes with up to 20 wt.% waste were prepared. The results showed that the ...


    By Inderscience Publishers

  • Honduras: Generating bioenergy from polluting waste ...

    The idea came up during the latest Expobioenergía Workshop The baselines of this idea were drawn up during the Expobioenergía 2010 Workshop, “at some stage of the tour we made of the various companies and projects we had the chance to visit during the event”, explains Julio César Lucas, a member of the Honduran firm Quimys’ Oil S. de R.L. Following its visit ...

  • Centralised treatment of oil sludge and other industrial waste

    Centralised treatment of various sources of industrial waste has been established in many European countries over the last decade. Many facilities are still equipped with non state of the art technology and therefore cannot fulfil the broad field of applications with regard to industrial waste remediation. econ's international client decided to be one step ahead and erected a new econ industries ...


    By econ industries GmbH

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you