on-site membrane performance testing Articles

  • INNOVATIVE CHEMICALS FOR DETERIORATED RO MEMBRANES

    The new rejuvenation chemical treatment is introduced in this paper. This chemical treatment repairs the deteriorated RO membranes, and recovers the salt rejection ratio immediately. In the past, such kind of rejuvenation methods have been developed and reported only with table test basis and pilot plant test basis as seen in the IVREFERENCES ...


    By Kurita

  • Silent Alarm software optimizes membrane plants

    Overview Since the advent of membrane technology applications in commercial and industrial water desalination and purification plants utilizing RO, NF, UF & MF processes, membrane manufacturers, system suppliers and end-users alike have been facing two major problems: how to adequately and reliably monitor membrane system performance and how to detect membrane fouling and scaling ...


    By MASAR Technologies, Inc.

  • Application of Membrane Technology for the Recovery and Reuse of Water

    Abstract As water and sewer costs are expected to increase over the next decade, membrane technology will continue to be a viable and economical option in the recovery and reuse of water. This paper describes the mechanism of membrane effected separation (specifically reverse osmosis, ultrafiltration and microfiltration), membranes commercially available, membrane element configurations, and how ...


  • Genairclean RO membrane cleaning - Case Study

    Trial Period September 2013 to May 2014 Site Water Reuse system, UK Background A Brackish Water Reverse Osmosis (BWRO) system with a history of rapid and consistent membrane fouling was selected to trial the new ‘Genairclean’ micro-bubble multi-mechanism RO membrane cleaning method. The plant reclaims process ...

  • European Retail Gasoline Site - Case Study

    ABSTRACT BOS 200® successfully remediated petroleum hydrocarbon impacts at an active retail petroleum facility in Europe, achieving the remediation goal of eliminating vertical migration of impacted groundwater to competent limestone aquifer underlain the site. CHALLENGES Site characterization activities following the release identified residual ...

  • Membrane process treatment for greywater recycling: investigations on direct tubular nanofiltration

    On-site greywater recycling and reuse is one of the main ways to reduce potable water requirement in urban areas. Direct membrane filtration is a promising technology to recycle greywater on-site. This study aimed at selecting a tubular nanofiltration (NF) membrane and its operating conditions in order to treat and reuse greywater in buildings. To do so, a synthetic greywater (SGW) was ...


    By IWA Publishing

  • 600 MLD Membrane Bioreactor for Tertiary Nitrification in Hamilton, Ontario

    The City of Hamilton is faced with increasing pressure from growth and development, greater wet weather treatment needs, and stringent effluent targets. In order to address these challenges, the City of Hamilton has initiated an ambitious program to identify alternative upgrade options for the Woodward Avenue WWTP. One of the alternatives identified for further investigation is a tertiary ...

  • Two Case Histories of Industrial Water Reuse Via Membrane Technology

    Abstract This paper describes two successful applications of ultrafiltration (UF) and reverse osmosis (RO) membrane technology used to reclaim water, reduce waste water discharge costs. The first case history covers oily waste water treatment at a major aluminum beverage can manufacturing plant. The second case describes treatment of waste water from a multi-plating bath section of a major ...


  • Membrane Selection and Optimal Ammonium Nitrate Chemistry for Reverse Osmosis Treatment of Explosive Wastewater

    A process for manufacturing explosives produces an ammonium nitrate-laden wastewater, which can be successfully treated with reverse osmosis (RD). Key to RD use is balancing the competing waste solution chemistry requirements of the two target solutes, to enhance the performance of the particular RD membrane chosen. While the EPA requires only the reduction of the N03 and NH4+ discharge levels ...


  • High-performance geomembranemth evoh technology part of gas vapor mitigation solution case study

    Project: Chik-Fil-A Location: Fort Worth, TX Products: Liquid Boot PLUS Gas Vapor Mitigation System with VI-20™ Geomembrane GeoVent™ Gas Venting System Background: The owner of the former manufacturing site and the engineer understood the value of having a barrier with superior vapor resistance and a long standing ...


    By CETCO

  • Program developed to ensure long-term O&M and performance of vapor intrusion mitigation

    EPA Region 7 has developed a comprehensive VI program to address the installation and long-term operation and maintenance (O&M) of VI mitigation systems, as well as assessment sampling for future systems, in homes near the Chemical Commodities, Inc. Superfund site (CCI). Region 7's VI Program Implementation Manual, which describes decision processes and procedures as well as roles and ...

  • Evaluation and Testing of Technologies for Brine Minimization at Eastern Municipal Water District

     ABSTRACT Eastern Municipal Water District (Eastern) in Southern California is facing increasing brine disposal challenges at its two inland desalter facilities. In most cases at inland sites, the disposal of brine involves either the dilution of the waste stream in another receiving body or the concentration of brine solutions (Truesdall et al., 1995). In the case of Eastern, brine ...

  • Case study: TOC recovery studies comparing combustion/NDIR with UV-persulfate/membrane conductometric methods for municipal raw and finished drinking water monitoring

    Objective Numerous studies have been conducted to compare the performance of various TOC methodologies on a wide range of raw source water and finished drinking water samples. The methodologies studied are those that are approved for TOC monitoring under the USEPA’s Disinfectants and Disinfection Byproducts Rule (D/DBPR). The results of these studies demonstrate that ...


    By GE Analytical Instruments

  • Improvement of an Industrial Wastewater Treatment System at a Former Viscose Rayon Plant – Results From Two-Stage Biological Leachate Treatability Testing

    Leachate is currently being pumped from three surface impoundments filled with waste material from the production of viscose rayon at the former Avtex Fibers plant. The primary objective of this study was to optimize a two-stage biological treatment process that has the potential to effectively treat a wastewater stream containing high levels of reduced sulfur compounds while also removing ...

  • Spiral-Wound Elements for Potable Water Treatment

    Introduction Any new technology must overcome perceptions of the marketplace, which are not accurate. As a technology moves into new areas of application, new misconceptions also arise. Crossflow membrane technology is no exception. The first man-made, pressure-driven 'crossflow' membranes were made in flat sheet form. This membrane had to be configured in a device, and was first made in ...


  • Economic and Environmental Benefits Flow From Filtration Technology

    Crossflow filtration operations typically fall into one of four categories: microfiltration (MF), ultrafiltration (UF), nanofiltration (NF), and hyperfiltration more commonly known as reverse osmosis (RO). The most common of the operations is reverse osmosis due to its ability to remove dissolved impurities including dissolved salts. Crossflow filtration machines typically include the membrane ...


  • Strict quality assurance procedures ensure reliable vapor intrusion protection case study

    Project: Toronto Fire Services Location: Totonto, ON, Canada Products: Liquid Boot Gas Vapor Mitigation System Background: Vapor intrusion has become a significant environmental issue for regulators, industry leaders, and concerned residents nationwide. The use of a spray-applied gas vapor barrier to protect against the ...


    By CETCO

  • From Pilot Studies to Full Scale Plant

    Natural gas is widely used as a primary energy source and is one of the most efficient fuel source. For this reason, more and more gas is utilized exceeding existent production facilities. Oil and gas companies therefore expand there measures and step behind borders finding and exploit new resources. One area of major interest is the Barents Sea, a remote area far from industry and civilisation. ...


    By EnviroChemie GmbH

  • ASC Tech Services

    Environmental contamination is risky business, to access risk, high-tech and unique geophysical site characterization methods can be employed. By utilizing these high tech gadgets that describe the ground and detail exactly what can’t be seen. Just like the Silicon Valley, new methods have surfaced and now more than ever it is easy to characterize the subsurface using direct push tools. ...


    By ASC Tech Services

  • DNAPL Characterization Methods and Approaches, Part 2: Cost Comparisons`, Ground Water Monitoring & Remediation

    Contamination from the use of chlorinated solvents, often classified as dense nonaqueous phase liquids (DNAPLs) when in an undissolved state, pose environmental threats to ground water resources worldwide. DNAPL site characterization method performance comparisons are presented in a companion paper (Kram et al. 2001). This study compares the costs for implementing various characterization ...


    By QED Environmental Systems

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you