organic rankine cycle power Articles

  • Organic Rankine Cycle (ORC)

    Biogas/Heat-to-Power Application using a Dreyer & Bosse CHP power unit Location: Trechwitz, Germany Site Gross Power Output Range 500Kwe + 30-35kWe from Electratherm ORC Thermal Heat Input Range: ?375-450kWt   Hot Water Input Range:? 90-95°C ...

  • Utilizing Waste Heat For Power

    Continuous duty gen-sets provide base-load power generation in diverse applications around the globe. However, high fuel costs and engine maintenance are pain points felt by operators. A low-maintenance path to significant fuel savings and lower emissions is what the U.S. Department of Defense (DOD) had in mind when they approached ElectraTherm to integrate the company’s Green Machine waste ...


    By ElectraTherm

  • Using biogas for combined heat and power

    An integral part of the majority of anaerobic digestion facilities across the world is the CHP combined heat and power (CHP) engine. For the first time builder of a biogas plant, it is often neglected as the focus is on reducing the capital costs ...


    By Clarke Energy

  • Using biogas for combined heat and power

    An integral part of the majority of anaerobic digestion facilities across the world is the CHP combined heat and power (CHP) engine. For the first time builder of a biogas plant, it is often neglected as the focus is on reducing the capital costs ...


    By Clarke Energy

  • Case study - Heat-to-power application using a Dreyer & Bosse CHP power unit with an internal combustion engine

    Location: Trechwitz, Germany Site Gross Power Output Range 500kWe + 30-35kWe from ElectraTherm ORC Thermal Heat Input Range:  375-450kWt Hot Water Input Range:  90-95°C (118-203°F) Hot Water Flow Range:  39 m3/hour (172 GPM) Ambient Temperature: 0-15°C (32-59°F) ElectraTherm installed a Green Machine in Germany at a biogas power generation ...


    By ElectraTherm

  • Case study - Heat-to-power application using a Dreyer & Bosse CHP power unit with an internal combustion engine

    Location: Trechwitz, Germany Site Gross Power Output Range 500kWe + 30-35kWe from ElectraTherm ORC Thermal Heat Input Range:  375-450kWt Hot Water Input Range:  90-95°C (118-203°F) Hot Water Flow Range:  39 m3/hour (172 GPM) Ambient Temperature: 0-15°C (32-59°F) Date Commissioned: Q2 2012 ElectraTherm installed a Green Machine in Germany at a ...


    By ElectraTherm

  • Energy and exergy analysis of a novel multigeneration system producing cooling, heating, power and pure water

    A novel multi–generation system producing power, pure water, cooling and heating is proposed and analysed in detail. The system comprises a hybrid generator-absorber heat exchanger (GAX), the Organic Rankine Cycle (ORC), the absorption heat transformer (AHT) and a desalination system. For comparison purposes, three working fluids, including R123, Isopentane and n–butane are considered in the ORC. ...


    By Inderscience Publishers

  • ElectraTherm Green Machine generates power from biomass in Italy - Case Study

    Site: Badia Prataglia, Italy Gross Power Output Avg: 46kWe Hot Water Input Range: 110°C Hot Water Flow: 10 l/s Thermal Input to the Green Machine (kW thermal): 500kWt ElectraTherm commissioned a Green Machine to generate emission-free electricity from biomass in Badia Prataglia, Italy. The facility operates a biomass boiler burning a mix of sawdust and ground up waste wood from ...


    By ElectraTherm

  • Case study - ElectraTherm generates power from low temperature geothermal

    Site: Florida Canyon, Nevada, USA Gross Power Output: up to 75kWe Hot Water Input Range: 225-230F Hot Water Flow: 150 GPM Thermal Heat Input: 660kWt Air Cooled Condenser ElectraTherm successfully commissioned its Green Machine at the Florida Canyon Mine in Imlay, Nevada. ElectraTherm marked the occasion at Florida Canyon Mine with a commissioning ceremony including officials ...


    By ElectraTherm

  • Case study - Green Machine uses biomass to put power back on the grid

    St. Helena Island, South Carolina Gross Power Output: up to 43kWe Thermal Heat Input: 200 - 500kWt Hot Water Input Range: 160 - 235°F Hot Water Flow: 150 GPM     Cold Water Input: 68°F Cold Water Flow: 150 GPM In fall 2010, American Capital Resources Company installed ElectraTherm’s heat-to-power Green Machine, for generating power from ...


    By ElectraTherm

  • Green machine generates power from waste heat at biogas facility in the Czech Republic

    Biogas/Heat-to-Power Application on Two MWM Internal Combustion Engines Site: Brno, Czech Rep. Engine Max Power: 980kWe (currently limited to 900 kWe) Green Machine Gross Power Output Avg:  32-39 kWe Thermal Input to the Green Machine: 375-500kWt Hot Water Input Range: 86 - 92°C Hot Water Flow: 35 m3/hour Ambient Temperature: 0-25°C ElectraTherm’s ...


    By ElectraTherm

  • Case study - Green Machine generates power from waste heat at biogas facility in the Czech Republic

    Biogas/Heat-to-Power Application on Two MWM Internal Combustion Engines Site: Brno, Czech Rep. Engine Max Power: 980kWe (currently limited to 900 kWe) Green Machine Gross Power Output Avg:  32-39 kWe Thermal Input to the Green Machine: 375-500kWt Hot Water Input Range: 86 - 92°C Hot Water Flow: 35 m3/hour Ambient Temperature: 0-25°C Date Commissioned: Q2 ...


    By ElectraTherm

  • Case study - ElectraTherm commissions 10 green machines on district heating system in Europe

    ElectraTherm commissioned 10 Green Machine 4400s in Levice, Slovakia in June 2014. ElectraTherm’s Czech distributor, GB Consulting, facilitated the deployment of Organic Rankine Cycle (ORC) systems on a centralized district heating system in Slovakia as a means of increasing on-site efficiency and generating clean energy. ElectraTherm’s Green Machine generates fuel-free, ...


    By ElectraTherm

  • Renewable resource Trechwitz ORC - Case Study

    This plant has an electrical output of 800 kW and a thermal power of 760 KW. At the biogas plant in Trechwitz, an unconventional heat utilisation model was installed. The waste heat from the CHP unit is used to generate power in an ORC unit (Organic Rankine Cycle). The heat goes into an evaporator, and the operating liquid is converted into pressurised steam. The steam is depressurised by ...

  • Challenges of Fuel Gas Purification for Cogeneration Under Stringent Regulatory Requirements

    ABSRTRACTInland Empire Utilities Agency (IEUA), a municipal water district based in Chino, CA is currently executing a cogeneration power project, titled Renewable Energy Efficiency Project (REEP) at the Regional Plant No.5 (RP-5), which showcases a variety of innovative technologies for the power production. The project involved many innovative technologies, most of which are still in the ...

  • Case study - green machine in Romania running off geothermal brine

    Gross Power Output Avg: 50kWe Thermal Heat Input: 700kWt Hot Water Input Range: 105°C Hot Water Flow: 10.1 l/s Average Ambient Temp: 12°C The Green Machine was commissioned at a geothermal well in Romania. The machine produces 50kW (gross) of electricity from the geothermal hot water (216°F/102°C) without any fuel or emissions. To further increase the ...


    By ElectraTherm

  • Case study - Solar thermal In Louisiana

    Solar Thermal/ORC Application in the USA Site Location: Crowley, LA, United States Thermal Power Available: Up to 650 kWt Green Machine Gross Power Output Avg: 15-50 kWe Hot Water Input Range: 65-120°C Water Cooling Tower: Up to 600 kWt ElectraTherm partnered with its gulf coast distributor, Gulf Coast Green Energy, to commission a Green Machine for a project sponsored by ...


    By ElectraTherm

  • Case study - ElectraTherm partners with GB Consulting and EnviTec Biogas on first of its kind biogas application

    Biogas/ORC Application on GE Jenbacher 412 Engine Site: Straznice, Czech Rep. Engine Power: 844kWe Green Machine Gross Power Output Avg: 30-40 kWe Thermal Input to the Green Machine: ~500kW Hot Water Input Range: 94°C Hot Water Flow: 12 l/s Liquid Loop Radiator Water Temperature: -7 to 40°C In the Czech Republic, ElectraTherm, distributor GB Consulting and ...


    By ElectraTherm

  • Case study - ElectraTherm green machines generate electricity from wood waste at mill in Oregon

    ElectraTherm commissioned its second Green Machine at an integrated wood products mill in Wallowa, Oregon. Together, the two machines operate off the waste heat of a biomass boiler to generate emission-free electricity. Integrated Biomass Resources (IBR) processes small-diameter timber into various wood products, such as firewood and fence posts. Wallowa Resources Community Solutions, Inc. ...


    By ElectraTherm

  • Allready-Box brings security to production of bioenergy

    Animal feed manufacturer Futtertrocknung Mindelheim eG of southern Germany has been operating a co-generation power station since 2008. During the summer months, this power station uses ecological methods to generate the heat and electricity the company needs to dry soilage. Utilizing a year-round, low-temperature heating network, it supplies local industrial firms and public institutions with ...


    By ALLWEILER GmbH

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you