orp sensor Articles

  • pH/ORP Sensors for Metallurgical Applications

    Importance of pH Measurement Hydrometallurgical concentrating and refining applications require pH/ORP sensors to withstand aggressive environments while maintaining accurate measurement. Processes such as cyanide leaching (e.g gold) and solvent extraction (e.g. copper, nickel, zinc) require pH and ORP to be at very specific values to yield the desired chemical species. pH may need ...


    By IC Controls Ltd.

  • Development of polymer lab-on-a-chip (LOC) for oxidation-reduction potential (ORP) measurement

    Reverse osmosis (RO) desalination has been recognized as a promising method to solve the water shortage problem. Nevertheless, since it is energy intensive and has many problems associated with biofouling/fouling of RO membranes in RO plants, its commercial acceptance is still slow. Especially, as high levels of oxidizing agents negatively affect RO membrane efficiency and life span. So, there is ...


    By IWA Publishing

  • Dynamic control of nutrient-removal from industrial wastewater in a sequencing batch reactor, using common and low-cost online sensors

    On-line control of the biological treatment process is an innovative tool to cope with variable concentrations of chemical oxygen demand and nutrients in industrial wastewater. In the present study we implemented a simple dynamic control strategy for nutrient-removal in a sequencing batch reactor (SBR) treating variable tank truck cleaning wastewater. The control system was based on derived ...


    By IWA Publishing

  • Stop metal losses in processes with Sulphide, Cyanide, Ammonia and Pressure Fluctuations

    Abstract Losses of metal are often traced to incorrect pH/ORP signals in floatation, leaching, extraction, electrolysis, and precipitation processes, aggravated by pressure changes. IC Controls a Canadian mining sensor manufacturer developed a new superior pH/ORP sensor that stops metal losses, reduces environmental footprint and contributes to sustainability. The cause of incorrect pH/ORP ...


    By IC Controls Ltd.

  • Continuous emission monitoring and control of packed tower odor control systems using the sycamore CEM

    ABSTRACT Packed-tower chemical scrubbers, with sodium hydroxide (caustic) and sodium hypochlorite (bleach), are commonly used to treat foul air from wastewater treatment processes. The available control mechanisms include a pH probe and controller for the sodium hydroxide feed, an oxidation reduction potential (ORP) probe with a controller toestablish the bleach feed, and proprietary ...

  • Improved Control for your Cooling Tower and Boiler

    The power of microprocessor based programming along with the ease of interfacing with standard Internet based controllers has enabled improved cooling tower and boiler control with just the click of a mouse. Many of these improvements can significantly enhance your chemical treatment program, and provide greater flexibility in your chemical treatment program. These new algorithms offer ...


    By Walchem, Iwaki America Inc.

  • The effect of nitrite on oxygen uptake in activated sludge as it relates to the redox potential

    The objective of this investigation was to show that the low nitrate bend in the redox potential curve is in fact the result of nitrite inhibition of oxygen uptake. The oxygen sensor used indicated traces of oxygen at the time of the observed low nitrate bend which supports the hypothesis. However, an oxygen sensor with a lower measuring range is needed in order to show conclusively that this ...


    By IWA Publishing

  • The Use of Oxidation-Reduction Potential as a Means of Controlling Effluent Ammonia Concentration in an Extended Aeration Activated Sludge System

    ABSTRACTThis study developed a strategy to control effluent ammonia from an activated sludge system, using oxidation-reduction potential. By controlling effluent ammonia concentrations, disinfection of treated wastewater is more cost effectively achieved by chloramination rather than break-point chlorination. The system under consideration was an extended aeration oxidation ditch. The study takes ...

  • Online Instrumentation to Protect Wastewater Facilities from Toxic Chemicals

    ABSTRACTSecurity concerns are driving current research to develop means of detecting toxic chemicals in wastewater influents as few online instruments are currently available for this purpose. Online respirometers such as the STIPTox are the obvious choice using existing, established technology. One of these units was recently used successfully in the WERF project 03-CTS-7S “Feasibility Testing ...

  • In-situ quality monitoring station in Lower Saxony

    Background 'Duemmer' is a shallow lake in the south-west of Lower Saxony; through the lake flows the river 'Hunte'. The catchment area spans 426 km2. With a surface of 12.4 km2 and an average depth of 1.1 m there is a water volume of approx. 14 million m3. Large parts of the lakeside are a nature reserve and the lake is a popular local recreation area. The lake suffers from strong nutrient ...

  • Wastewater engineers go with the flow

    The efficiency of maintenance work has been improved by water treatment engineers employing Intellisonde monitors in their final effluent. Designed primarily to measure water quality, the Intellisondes also measure flow, and this reading is being used to detect the accumulation of debris that necessitates a maintenance visit. Wastewater treatment efficiency is often measured by the analysis of ...


    By Intellitect Water Ltd

  • Controlling the addition of Chlorine into a Process

    There are several methods for controlling the addition of chlorine into a process. These methods include flow proportional injection, ORP (oxidation reduction potential) or a residual chlorine analyzer. Each method measures a different process characteristic. Depending on the specific type of process being controlled, there generally is a best choice for controlling the injection of either ...


    By Walchem, Iwaki America Inc.

  • Inhibition of unwanted nitrification

    Respirometer The respirometer utilized in this study corresponds to the BM-Advance model, with the following main features: Compact analyzer, with very low maintenance and user friendly operation Direct oxygen measurements from a maintenance-free oxygen sensor No oxygenation restriction during test performance Full control and results by ...


    By SURCIS, S.L.

  • Water quality in the Arosa Bay

    Background One of the great impediments to further development of shellfish aquaculture in the north-west region of Spain isa perception that industry expansion and tourism could have negative environmental effects on the coastal waters. Especially the bay around Villagarcia de Arosa is very famous because of its excellent areas for shellfish farming. The government of Spain is ...

  • In-pipe monitors turn dreams into reality

    In-pipe monitors turn dreams into reality The quality of tap water has improved enormously in recent decades, but for largely technological reasons, until recently, knowledge of water quality between the treatment works and the tap has been an almost impossible dream for water treatment and distribution network managers. In this article, Jo Cooper, Product Specialist at Intellitect Water, will ...


    By Intellitect Water Ltd

  • Case study - Groundwater monitoring around hydraulic fracturing sites in Colorado

    Hydraulic fracturing or ‘Fracking’ has become more prevalent and controversial in the US in recent years. More than 90 percent of new wells in the US are completed using this method. While it is endorsed by some as a game-changer that promises an increase in the nation’s economy due to energy independence, job creation, and lower energy prices; others are calling for a temporary ...

  • Unique technology for monitoring piped water

    INTELLITECT WATER has launched a unique, highly innovative drinking water monitoring technology that will revolutionise the delivery of drinking water. The new technology monitors the quality of water in pipeline distribution networks and for the first time provides reliable data to protect the integrity of the water quality, to enhance customer satisfaction and to improve operational efficiency. ...


    By Intellitect Water Ltd

  • Chlorine mystery solved

    Following the installation of in-pipe drinking water quality monitoring sondes, distribution engineers discovered an occasional significant disparity between the Intellisondes’ data and results from grab samples tested by a photometer tablet (DPD) method. For most of the time, there was close agreement between the two methods, but periodically, the photometer results varied wildly, whilst ...


    By Intellitect Water Ltd

  • Treatment of Cyanide Bearing Wastewaters

    Water Innovations utilizes a 2-stage Cyanide Oxidation (CN) system that can treat from 2 GPM to 10 GPM. In the first stage of treatment, hypochlorite oxidizes cyanide to cyanate. It consists of two double-wall “Batch” Cyanide Oxidation Tank and an accumulation tank for cyanide-bearing rinse water, each tank equipped with one mixer. Wastewater containing cyanide will be pumped or flow ...


    By Water Innovations, Inc

  • BM Respirometry a state of the art technology

    BM respirometery is a technology where the traditional and most advanced respirometry techniques are gathered in one exclusive design developed by SURCIS Company. BM Respirometry makes use of a single reaction vessel, that in certain modes, can replicate the actions that occur at a treatment plant within the conditions set for the test. The BM-respirometers, using powerful software, provide ...


    By SURCIS, S.L.