oxygen analyzer Articles

  • Development and Application of Oxygen Demand Testing using Industrial Effluent - Case Study

    Abstract The purpose of this study is to develop capacity and protocols for oxygen demand testing that can be used for instruction and research within the BioScience Technology program. For application purposes we chose the PeCOD® Analyzer which offers a unique nanotechnology-based approach to Chemical Oxygen Demand (COD) analysis. Background ...


    By MANTECH

  • PureAire Oxygen Analyzers & Oxygen Monitors for Nitrogen Generators

    Nitrogen has many uses in industrial applications where oxidation would be undesirable. From carbonizing beer to preserving food, reducing fire danger, and cleaning equipment, nitrogen is a safe, inexpensive gas. For companies that need a steady supply of nitrogen gas, nitrogen generators work well. Learn about the uses of nitrogen generators and why you should use oxygen monitors in ...

  • Using Anaerobic Biomass Digestion to Produce Hydrogen and Biofuel

    For many years, hydrogen has been considered as an alternative to fossil fuels. Now, Scientists are aiming to develop an environmentally friendly method to produce hydrogen from biomass by optimizing anaerobic digestion systems.1 Climate change, dwindling fuel resources and energy prices have spearheaded intensive efforts to detect and optimize ...


    By Edinburgh Instruments Ltd

  • PeCOD® Analyzer oxygen demand analysis for source & treated drinking waters

    MANTECH’s chemical oxygen demand (COD) analyzer is breaking new ground in the science of monitoring source and treated drinking water. In addition to providing 15-minute COD results and biochemical oxygen demand (BOD) estimates, MANTECH’s PeCOD® Analyzer measures natural organic matter (NOM) in raw and treated drinking water. The NOM Analyzer™  — which is the ...


    By MANTECH

  • PeCOD® Analyzer 15-minute chemical oxygen demand (C0D) analysis

    The revolutionary PeCOD® Analyzer technology provides Chemical Oxygen Demand results in under 15 minutes in a Simple-Safe-Effective manner. With our mercury and dichromate free chemistry installed in over 20 countries, the PeCOD® Analyzer has delivered successful test monitoring of COD in a variety of environments with our approved and published MOECC method  Through our proprietary ...


    By MANTECH

  • Boiler Dissolved Oxygen Control

    DISSOLVED OXYGEN CHEMISTRY Dissolved Oxygen (DO) is a measure of the amount of oxygen, usually thought of as a gas, that is dissolved in a liquid such as water. Oxygen is essential to life and is also the most common element found taking part in corrosion reactions. DO can be thought of as the fuel needed for the corrosion process to proceed. It is the corrosion reactions that necessitate ...


    By IC Controls Ltd.

  • What is Chemical Oxygen Demand (COD)?

    Chemical Oxygen Demand (COD) analysis is a measurement of the oxygen-depletion capacity of a water sample contaminated with organic waste matter. Specifically, it measures the equivalent amount of oxygen required to chemically oxidize organic compounds in water. Why Measure COD? COD is used as a general indicator of water quality and is an integral part of all water quality ...


    By MANTECH

  • PureAire Oxygen Analyzer for 3D Printers: How Argon is used and Why O2 Detection is Required

    Thanks to new technologies, the 3D printers that have been used to create plastic three-dimensional objects can now print metal. Titanium 3D printing is possible thanks to a technique called DMLS, or Direct Metal Laser Sintering. While the potential to use titanium 3D printing is groundbreaking for many industries, the new advances could pose a health hazard if volatile gases used in the printing ...

  • Patented method for oxygen permeation analysis of food packaging

    The PermMate utilizes an innovative method of oxygen permeation analysis of finished packages - ‘Ambient Oxygen Ingress Rate’ (AOIR). Providing the ability to test the oxygen permeability of packages under different test conditions including how the product ...


    By Systech Instruments Ltd

  • Application of chemical oxygen demand to drinking water

    “This study investigated the use of a photoelectrochemical chemical oxygen demand (peCOD) analyzer for the detection of model organic compounds and natural organic matter (NOM) from four drinking water treatment plants in Nova Scotia, Canada. Most model organic compounds showed ...


    By Camlab Limited

  • Chemical Oxygen Demand and Biochemical Oxygen Demand results in 15 minutes - Case Study

    Arauco, a Chilean pulp and paper company, has been using a PeCOD® Analyzer in full-scale operations since 2013. As a result, the company has reduced the use of hypochlorite in its bleaching processes with no loss of product quality, and decreased the amount of organics in its wastewater stream. The net result was a further reduction in chemicals and energy used in water treatment that saved ...


    By MANTECH

  • TOC analyzer for airports

    During winter, de-icing processes at airports necessitate storm water and de-icing water management. Especially due to adhesive (sticky) substances, strongly fluctuating concentrations and a lot of chemicals, the monitoring systems itself must be tailor-made to fight this water analysis challenge. LAR 's ...


    By LAR Process Analysers AG

  • Headspace gas and oxygen permeation analysis of food packaging designs - Case Study

    Food packaging designs tested using Systech Illinois gas analysis equipment At the Loughry Campus, Systech Illinois' headspace gas analyzer and oxygen permeation analyzer are used in the testing of food packaging. Located in Cookstown, County Tyrone, Northern Ireland, Loughry Campus offers educational and training programmes in all elements of Food Management. Students have ...


    By Systech Instruments Ltd

  • Application of advanced Respirometry in the Nitrification assessment for different levels of Temperature, pH and Oxygen

    Abstract Environmental factors control the rate of nitrification. For a determined substrate concentration, the most significant environmental factors are temperature, pH and oxygen availability. The well known critical influence of those factors on the nitrification are here analyzed by making use of a specific software and advanced respirometry based on a dynamic LFS system, ...


    By SURCIS, S.L.

  • Application of advanced Respirometry in the Nitrification assessment for different levels of Temperature, pH and Oxygen

    For a determined substrate concentration, the most significant environmental factors are temperature, pH and oxygen availability. The well known critical influence of those factors on the nitrification are here analyzed by making use of a specific software and advanced respirometry based on a dynamic LFS system, where the test conditions can be set in the corresponding test-settings board and ...


    By SURCIS, S.L.

  • Oxygen detection in manufacturing of precious and non-precious metal coins - Case Study

    Oxygen detection in heat treating/annealing furnace atmosphere in manufacturing of precious and non-precious metal coins Sunshine Minting use the Systech Illinois EC913 process oxygen analyzer to monitor the oxygen in their heat treating/annealing furnace attmosphere. Based in Idaho, U.S.A., Sunshine Minting Inc. (SMI) is a leading supplier of precious metal and base metal mint products. ...


    By Systech Instruments Ltd

  • A Nitrogen Culinary Experience and How to Remain Safe with Use of Oxygen Monitors

    As modernist cuisine has become more popular, restaurant and home chefs alike are turning to liquid nitrogen to create spheres, gels, foams, and even ice cream. While liquid nitrogen can be safely used in a range of culinary applications, there are important safety risks to be aware of when working with this substance.  The Hidden Dangers of Liquid Nitrogen in the ...

  • Characteristics and indications of hydrogen and oxygen isotopes distribution in lake ice body

    Stable isotopes have been used to identify the characteristics of precipitation, evaporation, basin hydrology, and residence times. However, lakes in the cold regions are usually covered by ice for 5–6 months. To get a better understanding of stable isotopes characteristics and indications in lake ice bodies, ice and water were sampled during the icebound season in both the ice and water ...


    By IWA Publishing

  • Measurement of Oxygen in CO Boiler of FCC Process – Case Study

    Background Fluidized-Bed Catalytic Cracking (FCC) is the most important and widely used refinery process for converting low value heavy oils into more valuable gasoline and lighter products. Application Description The catalyst is covered with carbon (coke) from the cracking reaction which lowers its activity. Therefore, the catalyst is fed to the ...

  • Analyzing for Trace CO and CO2 using a Total Hydrocarbon Analyzer

    Untitled Document The purity of Specialty Gases is determined by the measurement of various contaminants including Total Hydrocarbons. Low level measurements of carbon ...


    By AMETEK MOCON - Baseline

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you