particulate sampling train Articles

  • Sample Handling Strategies for Accurate Lead-In-Soil Measurements in the Field and Laboratory

    ABSTRACT The inhomogenous lead-in-soil matrix can present serious obstacles to accurate sample collection and handling. In typical lead-in-soil measurement, particle size related errors in sampling and sample handling often exceed all other sources of error. The magnitude of error can vary widely depending on the particulate nature of the lead contaminant and the effectiveness of control ...

  • Low-Flow (Minimal Drawdown) Ground-Water Sampling Procedures

    Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water ...


    By Solinst Canada Ltd.

  • Quantifying struvite formation in Calgary’s wastewater treatment system

    The paper presents a sampling and sample preparation protocol to evaluate struvite formation in the solids processing train of a wastewater treatment plant. The protocol was applied to the City of Calgary’s Bonnybrook and Fish Creek WWTP’s and the Shepard Sludge Lagoons. The soluble and particulate portions of magnesium, nitrogen and phosphorus (the chief components of struvite), as well as ...

  • New laser-based dust emission monitoring system

    Abstract A new generation of continuous particulate matter concentration monitoring instruments is presented, covering a measuring range of 0 to 1000 mg/m3. The laser-based scattered light instrument gives an improved stability as well as excellent resolution in the low range. This enables high concentration measurement as well as especially low emission monitoring down to 0.01 mg/m3 with a ...


    By Sigrist-Photometer AG

  • Slug of Hydrocarbon contaminating amine case study

    A Gulf Coast refinery’s amine system was contaminated with up to 3% hydrocarbon. The contamination consisted of hydrocarbon from upstream process units and particulate. The hydrocarbon consisted of LCO and heavy diesel. The current system consisted of an undersized flash tank and a 20% slipstream filtration. The current system could not remove the contaminants so the refinery had to ...

  • TOC analyser improves lab efficiency

    Leading instrumentation company HACH LANGE is helping a number of key customers save valuable time and costs with its new IL550 TOC-TN analyser. TOC analysis is vitally important in applications ranging from power generation, wastewater, drinking water, surface water and ultrapure water, to agricultural soils, contaminated land and food. HACH LANGE analysers therefore offer a range of options ...


  • Project profile - uranium treatment system Middletown Springs Elementary School Vermont

    Background The Middletown Springs Elementary School in Vermont is located in an area of the U.S. very susceptible to the formation of naturally-occurring uranium. Due to the high levels of uranium detected in the well water serving the School, it was placed on a “Do-not-Drink Advisory”. AdEdge was contacted by Otter Creek Engineering in June 2009 to assist the School in ...

  • Moisture in Oils: The Three-Headed Beast

    Abstract Moisture contamination in in-service lube oils is perhaps one of the most destructive forms of engine corrosion second only to particle contamination.  Water contamination in oil can be categorized into three forms of water; Free, emulsified, and dissolved.  All forms of water have direct consequences to the oil and gears of the engine, but indirect consequences as ...


    By Arizona Instrument LLC

  • FTIR gas analyzers support management of fire at UK waste facility

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents.  Arrangements have been made in England to bring together experts from the Environment ...


    By Gasmet Technologies Oy

  • Monitoring Environmental Quality

    ' In order to determine the effectiveness of actions to improve environmental quality it is necessary to be able to measure relevant environmental parameters at a level of detail which is accurate enough to distinguish the anticipated changes. However, the establishment and maintenance of monitoring systems is time-consuming and expensive and therefore the scale of such systems needs to be kept ...


    By The World Bank

  • Putting infection control into practice in the workplace

    Healthcare workers are, like patients, subject to illness from a variety of airborne pathogens common to hospital settings. This risk increases during construction and renovation, as these endeavors release dust as well as disease-inducing microbes into the surrounding environment. Since more than one in five workplace illnesses in private industry occur in a hospital setting , hospitals ...

  • Gas analysers support management of Swindon fire

    The capability to convene a multi-agency Air Quality Cell (AQC) was established in England in 2009 following the Buncefield Oil Storage Depot incident. A review of this event identified the need to rapidly co-ordinate the acquisition, analysis and interpretation of air quality data in major incidents. Arrangements have been made in England to bring together experts from the Environment Agency ...


    By Quantitech Ltd

  • Suggested Practice for Remediation of Highly Infectious Biological Agent Contamination in Indoor Environments

    Untitled Document PURPOSE This suggested practice describes those basic procedures to be followed, and precautions ...

  • Monitoring outfalls to Bathing Waters - Case study

    Bathing Water Catchment monitoring Date:2010 Location: Bude Cornwall UK Purpose: To carry out a river survey identifying potential pollution sources and their likely impact on bathing waters downstream. Background STS and the Environment Agency have, for some time, been discussing the issue of monitoring water courses which discharge directly into bathing waters. Of ...


    By Safe Training Systems Ltd

  • Case study - How to properly maintain and service your oxidizer

    Your air pollution control system represents a significant investment in not only initial capital but also ongoing maintenance and operation. Routine inspections performed by your staff combined with thorough maintenance plans provided by Anguil Environmental Service Technicians will ensure you get the most from your investment over the entire life of the system. Anguil has almost three decades ...

  • Comparative Risk Assessment

    ' Comparative risk assessment provides a systematic way to compare environmental problems that pose different types and degrees of health risk. It combines information on the inherent hazards of pollutants, exposure levels and population characteristics to predict the resulting health effects. Using data from available sources, rapid, inexpensive comparative risk assessments can identify the most ...


    By The World Bank

  • Research Projects Add Value to MSW Composting Facility

    Untitled Document By combining upfront separation for recyclables with intensive composting of MSW and biosolids, Florida's Sumter County ...


    By BioCycle Magazine

  • Differential Pressure and Temperature Monitoring in a Hospital Cleanroom

    Accsense A1-01a Wireless Environmental Data Loggers CHESTERLAND OH—April 9, 2012 CAS DataLoggers recently provided the wireless pressure and temperature monitoring solution for a hospital maintaining a surgery cleanroom to protect patients from a variety of environmental contaminants. Staff entered and exited through airlocks and were required to wear cleanroom suits before entering. Air ...


    By CAS DATALOGGERS

  • Stormwater Management for Urban Environments

    IntroductionElmhurst College, a hundred-thirty-five year old private learning institution, is proceeding with a campus redevelopment project that will include a one hundred seventy bed residence hall. In addition, the college continues to be a role model for sustainable site design and an educational resource for both students and the community.The need for additional housing, due to ...


    By Advanced Pavement Technology

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you