pcb sample Articles

  • Guidelines for the Identification of PCBs and Materials Containing PCBs

    This publication is intended to serve as a first guide on identifying PCBs and materials containing PCBs to assure the environmentally sound management of PCBs. It provides information on the known names, characteristics, and the uses for PCBs, as well as on the sampling and analysis techniques to indicate their ...


  • Detection of PCBs in wood

    MATRIX: Wood, reduced to fine shavings or sawdust ANALYTE: Polychlorinated biphenyls (PCB) LIMIT OF DETECTION: 2 ppm as Aroclor 1260 MATERIALS: PCB EnSys 12T Soil Test System, Equipment: Tools for reducing wood to fine particles (refer to sample treatment section below). SAMPLE ...


  • Detection of PCB on gauze wipes

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe, High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Kit and Sample Diluent. RaPID Prepä PCB Sample Extraction Kit. Reagents: hexane (pesticide grade). Equipment: 3 inch x 3 inch cotton gauze pads ...


  • Dioxin and PCB determination in foodstuffs

    SpeedExtractor E-914: Pressurized solvent extraction for the determination of dioxins and PCBs in dairy, egg, pork and fish The determination of dioxins and PCBs in foodstuffs is performed to monitor the potential exposure to humans. A reliable and fast  method is introduced. Proficiency test samples were extracted with the SpeedExtractor E-914, followed by an automated clean-up ...


    By BÜCHI Labortechnik AG

  • Detection of polychlorinated biphenyls (PCBS) in concrete

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: 500 ppb to 10 ppm MATERIALS: SDI PCB RaPID Assay® Kit. SDI RaPID Prep® PCB Sample Extraction Kit. SDI RaPID Prep Soil Collection Kit. Reagents: table salt (sodium chloride) or salt packets used by restaurants (e.g. Dixie ...


  • Surface Decontamination of PCBs (PCB-laden oil) by DeconGel 1101 and 1102

    Abstract Field testing aboard the USS Missouri maritime museum vessel showed that excellent surface decontamination was achieved by applying DeconGel™ 1102 onto contaminated surfaces, resulting in encapsulation of PCB contaminant by DeconGel's active components. For all contaminated surfaces tested, EPA PCB limit standards (Regulations 761.79, 761.123) of < 10 ug/100 cm2 were ...


    By METIS Scientific

  • RaPID Assay PCB in soil application

    Intended Use For detection of Polychlorinated Biphenyls (PCB’s) (as Aroclor 1254) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00137EA/A00137EB) Procedural Notes and Precautions ...


  • Sonic making inroads on PCB remediation?

    The Sydney Tar Ponds of Nova Scotia are the result of a century of coal mining and steelmaking, which left behind 900,000 tonnes of chemical waste. About 5 per cent or 45,000 tonnes of this waste is contaminated with high levels of PCBs. Two years ago a federal-provincial plan was announced to clean up the Tar Ponds over 10 years at a cost of $400 million, and this led to the creation of the ...


  • Analysis of PCBs in emission samples: non ortho, mono-ortho and homolog totals by level of chlorination

    IntroductionPolychlorinated biphenyls (PCBs) are one of the most widespread persistent organic pollutants, identified in every component of the global ecosystem. A production of approximately 2 * 10 9 Kg technical PCB occurred form 1930 to the late 1970 1 and the total amount released into the environment is estimated in 370. 000 2 tonnes. Twelve of the possible 209 PCBs are non- and mono-ortho ...


    By Monitoring Systems GmbH

  • Differentiating Polychlorinated Biphenyls (PCB’s) by GC / FID / ECD

    The analytical chemistry of PCB’s is rigorous, demanding the highest quality in sample preparation and analytical technique. Insufficient sample extraction and inappropriate methods of sample clean-up are the most common sources of error in PCB analysis, which causes significant interference in the chromatography. However, even in relatively clean samples the problem remains to confidently ...


    By Buck Scientific Inc

  • Small Diameter Pipe Wipe Sampling for PCBs: Technology Review and Status of EPA Approval

    ABSTRACT The Toxic Substances Control Act (TSCA) regulations governing management of polychlorinated biphenyls (PCBs) in the electric and gas industry include a series of options for abandoning pipe in place and managing pipe removed for disposal. The management options available to owners are different and, in some respects, more stringent for pipe that is less than or equal to 4 inches in ...


    By Weston Solutions, Inc

  • Determination of Polychlorinated Biphenyls (PCB) and Phthalates in Waste Polymer Samples intended for Mechanical Recycling

    The purpose of this study was to determine the levels of polychlorinated biphenyls (PCBs) and phthalates in homogenized polymer samples from polymer waste streams using two different pressurized fluid extraction instruments (ASE and SpeedExtractor). Both extraction methods showed very similar results. Measured PCB levels were in the lower and sub ppm range. Calculated total PCB levels using the ...


    By BÜCHI Labortechnik AG

  • Analysis of PCBs in emission samples: non ortho, mono-ortho and homolog totals by level of chlorination

    Polychlorinated biphenyls (PCBs) are one of the most widespread persistent organic pollutants, identified in every component of the global ecosystem. A production of approximately 2 * 10 9 Kg technical PCB occurred form 1930 to the late 1970 1 and the total amount released into the environment is estimated in 370. 000 2 tonnes. Twelve of the possible 209 PCBs are non- and mono-ortho substituted ...


    By Monitoring Systems GmbH

  • Analysis of PCB in water using the Dtech test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Color Card: 100 ppb (as aroclor 1254), DTECHTOR meter: 50 ppb (as aroclor 1254) BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A 1:2 dilution of the sample in methanol is made to minimize adsorptive losses. A ...


  • Analysis of PCB in water using the envirogard test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A chemical reaction is induced that causes a color change ...


  • Bioavailability and bioaccumulation of sediment‐bound PCBs to carp

    The relative bioavailability of sediment‐bound polychlorinated biphenyls (PCB 138, 153 and 180) from a local contaminated site was examined using an in vivo carp model. Surface sediment from the PCB contaminated site and spiked canola oil containing equivalent masses of PCBs were respectively incorporated in the “sediment‐dosed diets” and “oil‐dosed diets” at 3 dose levels resulting in 6 ...


    By John Wiley & Sons, Ltd.

  • Detection of PCB in water using the ensys test kit

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: 1260: 50 ppb 1254: 50 ppb 1248: 100 ppb 1242: 200 ppb 1232: 400 ppb 1016: 400 ppb MATERIALS: Ensys PCB 12 Test Kit, item # 7020301. Ensys PCB Soil Extraction Kit #7020300EA. Clean tap or deionized water. Equipment: Ensys Field System ...


  • Detection of PCB on gauze wipes using the rapid assay test system

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe. High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Test Kit (A00133) and Sample Diluent (A00136). PCB Wipe Sample Extraction Kit (A00137WA). Reagents: Methanol (ACS Reagent grade). Equipment: 3 inch x 3 ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the dtech test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: DTECHTOR: 500 ppb to 25 ppm (as aroclor 1254). Color Card: 1 ppm to 25 ppm (as aroclor 1254) MATERIALS: DTECH PCB Test Kit. DTECH PCB Sample Extraction Kit. Reagents: table salt (sodium chloride) or salt packets used by restaurants ...


  • Organochlorine pesticide and PCB residues in pharmaceutical, industrial and food grade fish oils

    Oils rendered from whole fish and from fish offal are an important primary dietary item in many areas of the world. In addition, fish oils are used extensively in the food industry as raw materials and ingredients. An extensive specialist market also exists for fish oils in dietary supplements. Traditionally, benefits have been conferred by their high vitamin D content in the prevention and cure ...


    By Inderscience Publishers