pcb test Articles

  • PCB removal

    Project Profile:PCB Removal from Ground Water DATA: End User: Aluminum Producer Location: Pacific Northwest, USA Commisioned: Summer, 2002 Units: (3) model FDB-340P (340 ft2/filter) Flow Rate: 12,000 gpm (17.3 Million gallons of water per day) ...


    By Filtra Systems

  • Detection of PCB in water using the ensys test kit

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: 1260: 50 ppb 1254: 50 ppb 1248: 100 ppb 1242: 200 ppb 1232: 400 ppb 1016: 400 ppb MATERIALS: Ensys PCB 12 Test Kit, item # 7020301. Ensys PCB Soil Extraction Kit #7020300EA. Clean tap or deionized water. Equipment: Ensys Field System ...


  • Analysis of PCB in water using the envirogard test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A chemical reaction is induced that causes a color change ...


  • Detection of PCBs in wood

    MATRIX: Wood, reduced to fine shavings or sawdust ANALYTE: Polychlorinated biphenyls (PCB) LIMIT OF DETECTION: 2 ppm as Aroclor 1260 MATERIALS: PCB EnSys 12T Soil Test System, Equipment: Tools for reducing wood to fine particles (refer to sample treatment section below). SAMPLE ...


  • Analysis of PCB in water using the Dtech test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Color Card: 100 ppb (as aroclor 1254), DTECHTOR meter: 50 ppb (as aroclor 1254) BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A 1:2 dilution of the sample in methanol is made to minimize adsorptive losses. A ...


  • Dioxin and PCB determination in foodstuffs

    SpeedExtractor E-914: Pressurized solvent extraction for the determination of dioxins and PCBs in dairy, egg, pork and fish The determination of dioxins and PCBs in foodstuffs is performed to monitor the potential exposure to humans. A reliable and fast  method is introduced. Proficiency test samples were extracted with the SpeedExtractor E-914, followed by an automated clean-up ...


    By BÜCHI Labortechnik AG

  • Detection of PCB on gauze wipes

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe, High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Kit and Sample Diluent. RaPID Prepä PCB Sample Extraction Kit. Reagents: hexane (pesticide grade). Equipment: 3 inch x 3 inch cotton gauze pads ...


  • Health Effects of PCBs

    Many studies have been performed in order to know the effects of PCBs on human health. Some of these studies suggest that PCBs are a possible factor in the appearance of cancer in humans who have been in contact with the substance, while they have already been demonstrated to cause a variety of adverse health effects and have been shown to cause cancer in animals. ...

  • Detection of PCB on gauze wipes using the rapid assay test system

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe. High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Test Kit (A00133) and Sample Diluent (A00136). PCB Wipe Sample Extraction Kit (A00137WA). Reagents: Methanol (ACS Reagent grade). Equipment: 3 inch x 3 ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the dtech test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: DTECHTOR: 500 ppb to 25 ppm (as aroclor 1254). Color Card: 1 ppm to 25 ppm (as aroclor 1254) MATERIALS: DTECH PCB Test Kit. DTECH PCB Sample Extraction Kit. Reagents: table salt (sodium chloride) or salt packets used by restaurants ...


  • Surface Decontamination of PCBs (PCB-laden oil) by DeconGel 1101 and 1102

    Abstract Field testing aboard the USS Missouri maritime museum vessel showed that excellent surface decontamination was achieved by applying DeconGel™ 1102 onto contaminated surfaces, resulting in encapsulation of PCB contaminant by DeconGel's active components. For all contaminated surfaces tested, EPA PCB limit standards (Regulations 761.79, 761.123) of < 10 ug/100 cm2 were ...


    By METIS Scientific

  • RaPID Assay PCB in soil application

    Intended Use For detection of Polychlorinated Biphenyls (PCB’s) (as Aroclor 1254) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00137EA/A00137EB) Procedural Notes and Precautions ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the ensys test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: Aroclor 1254: 0.5 ppm Aroclor 1260: 0.5 ppm Aroclor 1248: 1.0 ppm Aroclor 1242: 2.0 ppm Aroclor 1232: 4.0 ppm Aroclor 1016: 4.0 ppm MATERIALS: Ensys PCB in Soil Test Kit. Ensys PCB Sample Extraction Kit. Reagents: table salt ...


  • Firm pioneers PCB clean-up solution

    Untitled Document A Vancouver firm's bid to test a revolutionary technology that could provide a solution to the world's PCB problems was given initial support from Richmond's community ...


  • Activated Carbon Applications Excel at PCB Removal

    TIGG’s GAC adsorption equipment is used to remove PCBs from groundwater. For more than 50 years, polychlorinated biphenyls (PCBs) were commonly used in industrial materials including, caulking, cutting oils, inks, paints and as dielectric fluids in electrical equipment such as transformers and capacitors. Concerns over health effects led to a North American ban of ...


    By TIGG, LLC

  • Method of low temperature pyrolysis as an answer for PCBs utilization.

    When people buy new computers, TV-sets or trendy mobile phones they do not think much about the future of substituted models. In a consumer society where devices are changed due to their obsolescence rather than break down the problem of pollution by e-wastes becomes more relevant. Disposal of printed circuit ...


    By Technokomplex

  • The evaluation of extraction and cleanup methods for the determination of PCB aroclors in caulking and sealing material

    Buildings that were built and/or refurbished before 1977 may well have caulking used to seal masonry joints and windows that contain PCB Aroclor 1254 and/or 1260. The Aroclors were used as a plasticzier and were added to the material to ease application and improve resiliency. The caulking material has been mainly used when there are dissimilar materials, like brick next to concrete, metal window ...


  • Mishandling of Hazardous Materials & Contaminants, Asbestos, Lead, Mould & Fungus, PCB`S

    Untitled Document Everyday in Canada and the United States Hazardous Materials are being removed improperly contaminating the buildings we occupy. The hazardous materials including ...

  • Application of a Tenax model to assess bioavailability of PCBs in field sediments

    Bioavailability has been estimated in the past using equilibrium partitioning‐based biota‐sediment accumulation factors; however, these values are not always reliable using field‐collected sediments likely due to varying amounts of different types of organic carbon, particularly black carbon, in sediments. Therefore, improving approaches to better evaluate contaminant bioavailability in sediment ...


    By John Wiley & Sons, Ltd.

  • Extraction of Sediment using the SpeedExtractor E-916 for the determination of Polychlorinated Biphenyls (PCBs)

    PCBs were used as coolants and dielectric fluid in transformers, as flame retardants, hydraulic fluids and additives in plastics and for many other applications until the 1980s. They are toxic, persistent and bioaccumulate in terrestial and aquatic biosystems and due to atmospheric effects they are ubiquitous in the environment. Sediment samples from a round robin program (SETOC 2008/4, Wepal, ...


    By BÜCHI Labortechnik AG

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you