pcb test kit Articles

  • Detection of PCB in water using the ensys test kit

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: 1260: 50 ppb 1254: 50 ppb 1248: 100 ppb 1242: 200 ppb 1232: 400 ppb 1016: 400 ppb MATERIALS: Ensys PCB 12 Test Kit, item # 7020301. Ensys PCB Soil Extraction Kit #7020300EA. Clean tap or deionized water. Equipment: Ensys Field System ...


  • Analysis of PCB in water using the Dtech test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Color Card: 100 ppb (as aroclor 1254), DTECHTOR meter: 50 ppb (as aroclor 1254) BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A 1:2 dilution of the sample in methanol is made to minimize adsorptive losses. A ...


  • Analysis of PCB in water using the envirogard test system

    MATRIX: Water ANALYTE: PCB LIMIT OF DETECTION: Aroclor 1248: 1 ppm Aroclor 1260: 2 ppm Aroclor 1242: 2 ppm Aroclor 1254: 1.1 ppm BACKGROUND: This application describes a field screening method for determining PCB concentrations in water. A chemical reaction is induced that causes a color change ...


  • Detection of PCB on gauze wipes

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe, High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Kit and Sample Diluent. RaPID Prepä PCB Sample Extraction Kit. Reagents: hexane (pesticide grade). Equipment: 3 inch x 3 inch cotton gauze pads ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the dtech test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: DTECHTOR: 500 ppb to 25 ppm (as aroclor 1254). Color Card: 1 ppm to 25 ppm (as aroclor 1254) MATERIALS: DTECH PCB Test Kit. DTECH PCB Sample Extraction Kit. Reagents: table salt (sodium chloride) or salt packets used by restaurants ...


  • Detection of PCB on gauze wipes using the rapid assay test system

    MATRIX: Cotton gauze pad (wipe) ANALYTE: PCB RANGE OF DETECTION: Low range: 5 to 100 mg per wipe. High range: 25 to 500 mg per wipe MATERIALS: PCB RaPID AssayÒ Test Kit (A00133) and Sample Diluent (A00136). PCB Wipe Sample Extraction Kit (A00137WA). Reagents: Methanol (ACS Reagent grade). Equipment: 3 inch x 3 ...


  • RaPID Assay PCB in soil application

    Intended Use For detection of Polychlorinated Biphenyls (PCB’s) (as Aroclor 1254) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00137EA/A00137EB) Procedural Notes and Precautions ...


  • Detection of polychlorinated biphenyls (PCBs) in concrete using the ensys test system

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: Aroclor 1254: 0.5 ppm Aroclor 1260: 0.5 ppm Aroclor 1248: 1.0 ppm Aroclor 1242: 2.0 ppm Aroclor 1232: 4.0 ppm Aroclor 1016: 4.0 ppm MATERIALS: Ensys PCB in Soil Test Kit. Ensys PCB Sample Extraction Kit. Reagents: table salt ...


  • Use of PCB RaPID ASSAY kits for semi-quantitative screening consistent with SW-846 method 4020

    BACKGROUND The Methods Section of the EPA Office of Solid Waste (OSW) has stated a need for more rapid, less expensive field screening procedures that do not compromise the accuracy of contaminant evaluation. The OSW screening approach incorporates a single point threshold or multiple individual point discriminators giving results in semiquantitative ranges lying between these points. SDI ...


  • Small Diameter Pipe Wipe Sampling for PCBs: Technology Review and Status of EPA Approval

    ABSTRACT The Toxic Substances Control Act (TSCA) regulations governing management of polychlorinated biphenyls (PCBs) in the electric and gas industry include a series of options for abandoning pipe in place and managing pipe removed for disposal. The management options available to owners are different and, in some respects, more stringent for pipe that is less than or equal to 4 inches in ...


    By Weston Solutions, Inc

  • What’s Good About Allegro PCB Editor Backdrill Capability? New Capabilities in 17.2!

    The 17.2 Allegro PCB Editor has improved backdrill capabilities. Backdrill data is now stored in the library padstacks and utilized at the design level during the analysis and backdrill generation process. Padstacks which do not have pre-defined backdrill information ...


    By PCB Piezotronics, Inc.

  • Vapor-Phase Biofilters Show Promise for Treating High VOC Emissions

    Evaluating the Feasibility of Natural AttenuationUsing natural attenuation to remediate organic compounds in groundwater has gained popularity. In some cases, this process can reduce contaminant levels to below risk-based corrective action criteria or regulatory standards without implementing additional remedial action alternatives. However, it is often difficult to prove that natural ...


  • Vapor-Phase Biofilters Show Promise for Treating High VOC Emissions.

    Evaluating the Feasibility of Natural AttenuationUsing natural attenuation to remediate organic compounds in groundwater has gained popularity. In some cases, this process can reduce contaminant levels to below risk-based corrective action criteria or regulatory standards without implementing additional remedial action alternatives. However, it is often difficult to prove that natural ...


Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you