  • Seven Ways Your Facility Isn’t Meeting Effluent Regulations and How to Solve Them

    Whether you own, operate, or help manage a municipal or industrial facility that deals with wastewater, it’s important to understand how wastewater treatment can play a significant role in the overall health of your business, especially when it comes to meeting effluent regulations. This is an important part of the wastewater treatment process to consider, as ignoring it could earn your ...


    By SAMCO Technologies, Inc.

  • Ph and total solids control for concrete producers

    Fortrans Inc. manufactures a self-contained pH control and monitoring system that uses CO2 gas to neutralize high pH process water and lower total suspended solids in process water produced at ready mixed concrete plants. The Model 5000S pH Control and Monitoring System offers precise pH control, monitoring of pH and lowers “Total Suspended Solids” of process water contained in pits, ...


    By Fortrans, Inc.

  • Chemicals used for pH Adjustment

    The Chemistry of Limestone Treatment: Limestone is an alkaline agent with the ability to neutralize, or partially neutralize strong acids. The neutralization process occurs when strong acids, in intimate contact with limestone chips, react with Calcium Carbonate (CaCO3, the primary constituent of limestone) to form water, carbon dioxide and calcium salts. The following depicts the neutralization ...


    By Digital Analysis Corp.

  • pH Adjustment - A Primer

    A brief review of the definition of pH, the pH scale, and some of the chemistry involved in pH Adjustment systems is provided below. For some this may be trivial, yet for many others this may be useful. The information provided below is typical of the background information we provide in our training classes / seminars. By Definition pH is the measure of free hydrogen activity in water and can be ...


    By Digital Analysis Corp.

  • Cycle chemistry pH measurement

    pH measurement in high purity water has met with variable success. The high resistivity of pure water, the vulnerability to contamination, the variability of reference electrodes and additional temperature effects converge to make tins a particularly challenging measurement. Overcoming these obstacles requires a thorough understanding of the potential problems and their systematic solution. ...


    By SnowPure Water Technologies

  • pH control for enhanced reductive bioremediation of chlorinated solvent source zones

    Enhanced reductive dehalogenation is an attractive treatment technology for in situ remediation of chlorinated solvent DNAPL source areas. Reductive dehalogenation is an acid-forming process with hydrochloric acid and also organic acids from fermentation of the electron donors typically building up in the source zone during remediation. This can lead to groundwater acidification thereby ...


    By True Blue Technologies, Inc.

  • ORP and pH Based Control of SBR Cycles for Nutrient Removal from Wastewater

    ABSTRACTContinuous monitoring of multiple process functions were conducted involving removals of BOD, TSS and nutrients, in each cycle of the SBR reactor at the wastewater treatment plant of the City of Carrabelle, FL. On line, real time, monitoring of pH, oxidation reduction potential (ORP), dissolved oxygen (DO), ammonia-N, nitrite-N, nitrate-N and orthophosphate-P demonstrated excellent ...

  • The Control of pH and Oxidation Reduction Potential (ORP) in Cooling Tower Applications

    The importance of keeping cooling tower water in proper chemical balance is becoming clearer. Cooling tower treatment control systems can limit scale formation to improve efficiency, limit corrosion to increase the service life of the cooling water system, and maintain a residual halogen level to reduce liability associated with biological growth, particularly Legionellae.   The use of ...


    By Walchem, Iwaki America Inc.

  • Getting back to basics: What is pH?

    Getting back to basics: What is pH? The most used measure in wastewater treatment, and for good reasons The “potential of hydrogen” or “pH” is the measure of free hydrogen activity in water and thereby indicative of the measure of its free acidity or free alkalinity. Gauged on a numeric scale of 0-14, solutions with a pH of less than 7.0 are acids. ...

  • Monitoring pH and ORP in a SHARON reactor

    This paper analyses the valuable information provided by the on-line measurements of pH and oxidation reduction potential (ORP) in a continuous single high ammonia removal over nitrite (SHARON) reactor. A laboratory-scale SHARON reactor equipped with pH, ORP, electric conductivity and dissolved oxygen (DO) probes has been operated for more than one year. Nitrogen removal over nitrite has been ...


    By IWA Publishing

  • pH and redox buffering systems of landfill leachate contaminated aquifer materials

    Introduction of landfill leachate into an aerobic aquifer leads to a variety of redox and pH buffering reactions between dissolved chemical species and aquifer sediments, which play profound effects on the behaviours of contaminants beneath and down gradient from the landfill. The specific objective of this study was to determine the spatial and temporal variations of pH and redox buffering ...


    By Inderscience Publishers

  • The next generation biological odour control systems

    Odour is usually caused by the presence of hydrogen sulphide, mercaptans (Organic sulphur components) and ammonia, but also multiple other VOC’s (volatile organic compounds) bringing numerous odour complaints at e.g. WWTP’s, pumping stations and composting plants. An odour control system therefore will have to treat not only hydrogen sulphide, but also other pollutants to reduce the total ...

  • Low-pH Ammonia Oxidation at a Biological Nutrient Removal Facility

    ABSTRACTMcAlpine Creek Wastewater Management Facility (MCWWMF), owned and operated by Charlotte Mecklenburg Utilities (CMU) of Charlotte, North Carolina, is permitted to treat 64 million gallons per day (mgd). Along with MCWWMF, three CMU treatment plants discharge effluent into the Catawba River just upstream of the South Carolina border. CMU worked with North and South Carolina regulators ...

  • Controlling scale in water systems helps prevent legionella

    The Legionella bacterium, Legionella Pneumophila (LP), the fundamental agent of Legionnaire’s Disease, is a water-based organism, which causes infection when inhaled in an aerosol form. Legionnaires' Disease acquired its name in 1976 when an outbreak of pneumonia occurred among persons attending a convention of the American Legion in Philadelphia. Later, the bacterium causing the illness ...

  • Controlling Algae in a Wastewater Lagoon

    In wastewater lagoons, single cellular algae can cause significant problems by effecting DO, pH, and TSS levels.  While algal growth does provide some benefit in reducing nutrient levels within the lagoons, it is imperative that the algae be controlled so as to minimize the negative impacts on the water quality in the lagoon effluent.  This article explores the impact that Bio-Domes ...

  • Continuous emission monitoring and control of packed tower odor control systems using the sycamore CEM

    ABSTRACT Packed-tower chemical scrubbers, with sodium hydroxide (caustic) and sodium hypochlorite (bleach), are commonly used to treat foul air from wastewater treatment processes. The available control mechanisms include a pH probe and controller for the sodium hydroxide feed, an oxidation reduction potential (ORP) probe with a controller toestablish the bleach feed, and proprietary ...

  • 3 Essential Things You Need to Know Before Buying a pH Data Logger

    Measurement of the pH of a solution is very common in industrial manufacturing processes, plating, wastewater treatment and environmental monitoring. Logging this data provides you with information on long-term trends and the impact of various external factors on changes in pH, and can also be used for control, compliance reporting and alarming. However, to capture accurate pH measurements with ...


    By CAS DATALOGGERS

  • National instruments features Watertectonics` Waveionics user interface and control system

    Using National Instruments products like LabVIEW and Compact FieldPoint Controllers, WATERTECTONICS has developed a user interface for the WaveIonics electrocoagulation system that is flexible, automated, and robust. With the tight integration between NI hardward and software, WATERTECTONICS was able to test coding extensively on a PC before deploying it to a system. Plus, it was easy to adapt ...


    By Water Tectonics, Inc.

  • Maintaining neutral pH in deep soils and ground water utilizing insoluble colloidal buffers.

    Optimal pH for most biodegradation processes falls between 6.5 and 8.5. Enhanced bioremediation in poorly buffered soils and ground water is likely to lower pH below 6.5 as the added electron donor produces carbon dioxide and organic acids. The common agricultural practice of liming soils adds alkalinity and adjusts soil pH by mixing finely divided insoluble calcium carbonate into the shallow ...


    By RNAS Remediation Products

  • Boiler Dissolved Oxygen Control

    DISSOLVED OXYGEN CHEMISTRY Dissolved Oxygen (DO) is a measure of the amount of oxygen, usually thought of as a gas, that is dissolved in a liquid such as water. Oxygen is essential to life and is also the most common element found taking part in corrosion reactions. DO can be thought of as the fuel needed for the corrosion process to proceed. It is the corrosion reactions that necessitate ...


    By IC Controls Ltd.