polymer pump Articles

  • Optidose polymer

    Maintaining a minimum concentration of an effective dispersant polymer is crucial in an alkaline cooling water treatment program. The problem is knowing exactly how much polymer is available in the cooling water to combat fouling and corrosion of heat transfer equipment. Many years of research and effort have gone into the development of a method for tracing the concentration of polymers. Rohm ...


  • Impact of heating method on the flocculation process using thermosensitive polymer

     Flocculation process based on water soluble polymers as flocculating agents is still intensively researched nowadays, despite the introduction of these materials about fifty years ago. There is a need to gain the full control of this process in order to obtain high efficiency and strictly define products. For that purpose new solutions are proposed like stimuli-responsive macromolecules. In ...


    By IWA Publishing

  • Installation of a deep drainage trench by the bio-polymer slurry drain technique

    Introduction An underground diesel fuel spill at a county bus maintenance facility in San Jose, California was successfully remediated by constructing a pair of 50 feet deep, gravel-filled extraction trenches. Well casings with ejector pumps were set into the trenches for withdrawing the diesel fuel contaminated groundwater to a small, onsite treatment plant. Severe access restraints, the ...


    By Geo-Con, Inc.

  • The design of static mixer heat transfer equipment for adhesives, sealants, resins and polymers.

    The fluids handled within the adhesives and sealant industries are amongst the most difficult to handle of any in the main process industries globally. The characteristics which make them particularly difficult to handle include: High viscosities (typically 1-2000 Pa.s, or 1000 to 2 million cP). Often non-Newtonian (viscosity is not constant and varies with shear rate). Some ...


    By National Oilwell Varco

  • BM Respirometry Study Toxicity & Biodegradability of a Refinery polymer stream, when treated in the activated sludge process of the plant - Case Study

    This “batch system” respirometer consists of: a single thermostatically controlled vessel, divided into two interconnected compartments with closed recirculation loop between the two. A constant air flow is supplied via a ceramic diffuser in the conditioning compartment, and a combined oxygen/temperature sensor in the reaction compartment controls the DO and temperature. Both ...


    By SURCIS, S.L.

  • Chopper Pumps: Saeby fish processing plant, sludge tank mixing and pumping

    The sludge is coming from the dewatering unit, includes polymers, and has a dry matter content of 15 %. A Landia dry installed pump type MPTKR-I 18,5 kW pump was installed. The pump mixes the tank contents through a recirculation system and pumps the sludge to a tanker truck. The pump was built with a special feeder propeller to make sure it could handle the high dry matter content. The ...


    By Landia

  • Pumping Polyelectrolyte in waste water treatment

    The Challenge An industrial waste water treatment company required a cost effective solution to pumping polyelectrolyte. The plant engineers approached Verderflex distributor, Global Pumps Australia, for a solution to the following problems: Existing helical rotor pumps were expensive to run and maintain The replacement pump would have to be able to ...

  • Mono nov tailors pumping solutions for allied colloids

    Based in Bradford, Allied Colloids’ Engineering Equipment division is responsible for providing customers withthe appropriate technology to ensure that the chemicals manufactured by its production division are utilised efficiently. A number of pumps were required to fulfil two main duties on the flocculant preparation and dosing rigs; a largerpump to transfer the mixed and aged flocculant at ...


  • Verderflex Peristaltic Industrial Pumps excel in diverse applications

    Verderflex Industrial peristaltic pumps are extremely robust pumps, ideal for heavy duty operations on intermittent or continuous duty cycles. They are a simple to use, easy to control, versatile and reliable way to pump liquids. Verderflex Industrial pumps can be used in a broad range of applications: Anaerobic Digestion Sludge Transfer Verderflex pumps were specified due ...

  • Leachate Collection & Removal Systems – Pump Stations

    Romtec Utilities designs and supplies pump stations for many different types of applications, including leachate collection and removal systems. Leachate pump stations are required whenever water passes through a bed of solids and extracts contaminating elements. The most common scenario for collecting and pumping leachate is for landfills, but there are industrial ...


    By Romtec Utilities Inc.

  • Analog and Digital Drives for Chemical Feed Pumps

    Dart Controls offers DC drives with the essential features required for water/wastewater and chemical feed applications. These drives integrate easily with PLC / SCADA systems providing 4-20mA signals for pump set speed.  Advanced Digital DC drives offer verified actual speed feedback, diagnostic and process alarms and much more…. The 253G-200E-7 is our most popular DC drive. This ...


    By Dart Controls, Inc.

  • Raw water clarification by flotation with microbubbles and nanobubbles generated with a multiphase pump

    Raw water clarification by flotation was studied by injecting air into a centrifugal multiphase pump to generate microbubbles (MBs) and nanobubbles (NBs). Measurements of gas dispersion parameters were performed and optimal conditions were obtained using a pump pressure of 4 bar. Values showed a bubble Sauter diameter of 75 μm, an air holdup of 1.2%, a bubble surface area flux of 34 s−1 and an ...


    By IWA Publishing

  • Case study - Veolia MPPE Technology - LMBV Schwarze Pumpe - DE

    Groundwater remediation Former brown coal conversion site Five MPPE units Operational since 2002 Challenge 2 years of intensive testing Reinfiltration of purified water Ideal to enhance insitu biodegradation Enhanced DNAPL & LNAPL removal with surfactant ...

  • Whole Life Costs and pumping Technology – Peristaltics Increasingly Out on Top

    Untitled Document Whole life costs are playing an ever-more important role in pump selection by the water and wastewater industry. Interestingly, energy use is no longer the ...

  • Peristaltic Pumps - A lot more than just heavy duty

    By design, the peristaltic pump is ideal for the dependable handling of abrasive, corrosive, viscous, high density and high solid content fluids. It thrives in those applications where other types of pump fail. Water and waste water industries, mining and chemical processing are all prime markets for this workhorse. But being equal to the tough demands of these applications is far from its only ...

  • Made to Bear Extreme Conditions

    Working below sea level, 24 hours a day, 7 days a week, subsea pumps are high-power and high-speed rotating equipment that perform under extreme conditions. Every single part of the pump has to be designed to be extremely reliable and must be tested intensively. The newly developed tilting-pad bearings offer advantages that can be used in other areas of application as well. Certain ...


    By Sulzer Management Ltd

  • Peach Processing Wastewater Treatment

    A major fresh pack operation of peaches and nectarines needed a screening system to remove the labels and peach fuzz from their wash water before it was pumped from the pond for irrigation use. Flow to the pond is a steady flow of 50 gpm, rising to 600 gpm during periodic draining of the peach coolers and washing systems. The water is a combination of wash water, labels and fuzz from the fruit, ...


    By Integrated Engineers Inc.

  • Monitoring vibrations, mechanical seals, and bearings for safety and performance

    With more than 70 years of experience in plastics processing, Switzerland-based Quadrant Group is a leading expert in a wide range of polymer materials and technologies for polymer conversion. In order to maintain a high level of quality in the production process, Quadrant's heat-transfer pumps must work safely and reliably. These pumps are commonly subjected to high loads. At the same time, ...


    By ALLWEILER GmbH

  • Municipal WWTP Digester Cleanout - Jekyll Island, Georgia - Case Study

    Coastal Georgia's Jekyll Island Stale Park, a popular vacation destination, is also home to about 750 permanent residents. John Day, Superintendent of the Water and Wastewater plants, operates the Jekyll Island Authority's I MGD wastewater treatment plant. Structural modifications and improvements to the plant's two anaerobic digesters were scheduled for early 2004. The job was publicly bid and ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you