power monitoring system Articles

  • Why are we monitoring nutrients at different depths?

    Recently, LG Sonic introduced the MPC-Lab, an innovative monitoring buoy that can monitor algae, physico-chemical variables, and even nutrients such as nitrogen and phosphorus in near real-time and at different depths in a body of water. Combined with our other monitoring tools, this system offers a unique way to detect the spatial and temporal patterns of nutrient concentrations which play a ...


    By LG Sonic

  • LG Sonic to automatically predict algal blooms

    LG Sonic will make use of Artificial Intelligence (AI) to further develop the software algorithm which will make it possible to predict algal blooms based on water quality data automatically. Furthermore, it will provide detailed information about the intensity and the impact of the algal bloom on the ecosystem of the water body. The updated algorithm will be implemented in LG Sonic’s ...


    By LG Sonic

  • Why Interactive Ultrasonic Programs are Important to Effectively Control Algae

    Many different algal types can bloom in a water body. Some of these algae are plant cells, while others are bacteria. Algae may vary in size, shape and cell characteristics. Typically, the type of algae that blooms depends on water temperature and sun hours. As a result, algal types may change several times during a season. To effectively  ...


    By LG Sonic

  • Online condition monitoring of electrical power system imbalance

    Symmetrical components are of great importance in many applications in electrical power systems, such as power protection and condition monitoring. This paper presents a computer-based algorithm for online symmetrical components estimation. The proposed algorithm uses the samples of the phase variables (currents or voltages) to estimate the magnitude and phase angle of each phase phasor at each ...


    By Inderscience Publishers

  • Bruce Power (Canada) Gamma Monitoring System - Case Study

    System description and operational performance after first winter period 2014/2015 The Bruce Power nuclear power plant (NPP) in Ontario, Canada, is the largest nuclear generating station in the world, operating 8 nuclear reactors producing 6300 MW. In correlation with Bruce Power’s safety culture, “Safety first” and continuous improvement are essential and substantial ...


    By Bertin Instruments

  • Application of the Most Recent Monitoring Systems in Hydro Power Plants

    Abstract The paper describes main reasons for refurbishment of hydro power plants and summarizes the most frequent works during refurbishment. A special attention is paid to the process of refurbishment of the electric equipment, in the first line generators and excitation systems, and integration of the most contemporary monitoring system. The paper talks about some of the methods of ...

  • Reliable silica monitoring supports power station efficiency

    West Burton B CCGT is a Combined Cycle Gas Turbine power station near Nottingham in the UK. It has three open-cycle gas turbines capable of generating enough electricity for approximately 1.5 million UK homes. In common with all combustion based power stations, the CCGT has a requirement to monitor silica levels in the Plant’s water and steam processes. Sean Todd, the Plant’s Control ...

  • Solar/wind power for noise monitoring terminals

    Solar Power Solutions A noise monitoring terminal’s (NMT) low power consumption and its ability to operate fully without power hungry cooling and heating units inside its enclosure mean that it is suitable for power from solar panels. The NMT may be continuously powered by battery which in turn is kept charged via solar energy. This solution is most appropriate in areas where there ...

  • Singular system analysis of the Local Power Range Monitor (LPRM) readings of a Boiling Water Reactor (BWR) in an unstable event

    Singular system analysis is a successful technique to separate oscillating components from a given signal. A methodology is proposed to apply this technique to the signals obtained from the LPRMs of a boiling water reactor core and extract the contributions of the in-phase oscillation and the out-of-phase oscillations from the LPRM readings during an unstable event. This methodology has been ...


    By Inderscience Publishers

  • Sewer Level Monitoring System - a case study

    Background - The business of sewage level monitoring in sewers is accelerating across many countries. Strict regulations, the need to avoid environmental disasters, violation fines, early warnings and planning needs are just some of the forces shaping this growing trend.   Challenges Quantifying sewage flow and level is one of the most ...

  • Monitoring System for Hydrologic Evaluation of Landfill Covers

    Three test sections were constructed and instrumented to assess the hydrologic behavior of earthen final covers at two municipal solid waste landfills. A traditional design using a “resistive barrier” was used for two of the test sections, whereas an alternative design using a “capillary barrier” was used for the third test section. The test sections were built in two distinctly different ...


    By ASTM International

  • New Condition Monitoring and Analysis System VDAU-6000

    Brüel & Kjær Vibro announces the world-wide release of the new VDAU-6000. This state-of-the-art condition monitoring system provides an economical alternative to rack-based systems for condition monitoring of rotating machinery, in particular auxiliary machines and balance-of-plant applications. The high density 16-channel parallel processing functionality also lends itself to the ...


    By Brüel & Kjær Vibro GmbH

  • New laser-based dust emission monitoring system

    Abstract A new generation of continuous particulate matter concentration monitoring instruments is presented, covering a measuring range of 0 to 1000 mg/m3. The laser-based scattered light instrument gives an improved stability as well as excellent resolution in the low range. This enables high concentration measurement as well as especially low emission monitoring down to 0.01 mg/m3 with a ...


    By SIGRIST - PHOTOMETER AG

  • Sewer Level Monitoring - Photos

    Sewer Level Monitoring - Photos Photos in this article present the complexity and versatility of sewer level monitoring. When examining the photos, pay special attention to the stand-alone autonomous characteristics of each installation. In lack of any cabling from the outside, whether data cables or power cables, the solution is fed from its own battery power supply. Data is tranmitted ...

  • Monitoring of water node in wroclaw

    Background Wroclaw's water node has complicated structure. The river Odra has 3 main riverbeds and a lot of channels which are located in the centre of town. There are almost 100 hydro buildings which control flow of the water through the city and protect it against theflood. The great flood in 1997 proved that no one has control over it. Communication systems failure caused ...


    By The OTT Hydromet Group

  • Climate monitoring - meeting the challenge

    Average global temperatures are on the increase, ice and snow cover is disappearing fast and sea levels are rising. In addition, severe weather situations are becoming more frequent and more extreme. There is clear evidence that the Earth’s atmosphere and oceans are warming: 11 of the 12 years in the period 1995-2006 were among the 12 warmest since 1850. Climate change is a reality and it is ...

  • Grille Monitoring in Scottish Borders

    Hydro-Logic was appointed to supply 4 trash screen monitors to the Scottish Borders Council. They were installed to monitor the level upstream of the screens and to provide alarms when the level reached a set threshold. This alarm was to be used by the council to indicate a build up of debris in front of the screen that would have created a flood risk potential. The alarms are transmitted along ...

  • Organics Monitoring: A Practical Guide

    Preventing product loss, lowering waste treatment costs, and reducing system maintenance and energy consumption through organics monitoring in the chemical, refining, food, and wastewater treatment industries. Summary Process water and steam condensate contamination includes organic, inorganic, and biological components. Sources of organic contamination include process ...


    By GE Analytical Instruments

  • Continous Emission Monitoring (CEMs)

    Presented in Track B1: CEMs at EUEC 2011,January 31 Phoenix, Arizona   B1.1  | Particulate CEM for wet FGD plant William Averdieck |  Managing ...

  • Plant area monitoring at Krško

    Post-Fukushima upgrades at Krško in Slovenia (www.nek.si) are being implemented in accordance with the requirements of the national regulator and the plant owners. The first phase, including a passive containment vent filtering system and hydrogen recombiners, a new emergency diesel generator, and a protected store of mobile emergency equipment, is already completed. The next phase in ...


    By Bertin Instruments

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you