process analyzer Articles

  • Applications of a Portable Gas Spectrometer

    In the realm of natural gas processing, enterprises don’t always find it economical to send products back to the lab and wait for test results. Being able to perform on-the-spot, highly accurate compositional analysis with gas chromatography equipment can reduce operational costs and help companies determine on-the-spot accurate gas levels in a natural gas stream. ...


    By Envent Engineering Ltd

  • Dry Air Scrubber for Propylene Oxide

    Background For decades, Advanced Air Technologies, Inc. has been the leader in air scrubber  technology for abatement of Ethylene Oxide (EtO) emissions.   In fact, AAT, Inc. was founded in 1987 on a unique dry scrubbing, chemi-sorption process for EtO.  The result is a series of fixed bed “Safe-Cell II” dry scrubbers, consisting of the DR-490, DR-50, and ...

  • The Seven Deadly Sins of Process Analyzer Applications

    Abstract On-line process gas analyzers comprise a relatively small proportion of the capital investment in a grass roots project but they require detailed attention if they are to be successfully implemented and fully exploited. The chain is long and the mistakes are many. It runs from front end engineering design, to EPC detailed design, through systems integration, selection of technique ...

  • New Process Gas Analyzer for the Measurement of Water Vapor

    KEYWORDS TDLAS, WMS, Laser Spectroscopy, Water Vapor Measurement, Gas Analyzer ABSTRACT A new analyzer for the measurement of water vapor concentration based on Tunable Diode Laser Absorption Spectroscopy (TDLAS) was developed. The water-vapor line at 1854-nm was selected for the measurement, and the performance of the system was evaluated on different ...

  • Reducing the Detection Limits for a Process Moisture Analyzer

    KEYWORDS Moisture Analyzer, Piezoelectric Sensor, Smart Transmitter, Internal Verification, Quartz-Crystal Microbalance ABSTRACT Piezoelectric moisture analyzers have been used in the process industry for over two decades. While this is an older technology for measuring moisture in gas phase samples, it is still one of the most reliable in ...

  • Online Analyzers Improve Control of Chloramination Processes in Milwaukee

    The Milwaukee Water Works is a national leader in providing high quality drinking water and monitoring water quality. Since 1998, it has invested $227 million in its infrastructure, from treatment plants to distribution systems, to ensure high quality drinking water and reliable supply. The Milwaukee Water Works treats Lake Michigan water with Ozone gas as a primary disinfectant because it ...

  • Curren Hits the Bull`s Eye Using Online Process Analyzers

    Howard F. Curren Advanced Wastewater Treatment Plant improved its efficiency by upgrading to online process monitoring and control. The Howard F. Curren Advanced Wastewater Treatment Plant is one of the largest nitrification/denitrification filter plants in the world with a design capacity of 96 million gallons per day average daily flow. It serves about 110,000 accounts in the City of Tampa and ...

  • Application Note: Wastewater Neutralization Process Using the Sievers InnovOx TOC Analyzer

    Industrial wastewater is a result of manufacturing, agricultural, environmental, and research activities. Managing the treatment and discharge of industrial effluents is a critical process that ensures compliance with regulatory ordinances, upholds public health and safety, and guarantees the protection of natural and public resources. Classical processes are typically employed to deal with ...


    By GE Analytical Instruments

  • Online Process Analyzer Installed at F.J. Horgan WTP to Monitor Chloramination

    Construction was completed on the City of Toronto's F.J. Hor-gan Water Treatment Plant in 1979, more than 60 years after chloramine had first been used to disinfect drinking water in an Ottawa plant. By then there was little debate about the benefits of chloramination and it was incorporated into the new plant's design as part of the disinfection process. Chloramine is more stable than free ...

  • Research NOx Analyzers

    ECO PHYSICS provides environmental experts with exceptionally sensitive and precise NOx measurement instruments. Please take a look at our newest press release on our research NOx analyzers below. Bound by the same laws of nature, ecology and physics are close associates in an on-going battle to preserve air quality around the globe. One of our planet's champions is Swiss-based ECO PHYSICS. The ...


    By ECO PHYSICS INC.

  • TOC analyzer for airports

    During winter, de-icing processes at airports necessitate storm water and de-icing water management. Especially due to adhesive (sticky) substances, strongly fluctuating concentrations and a lot of chemicals, the monitoring systems itself must be tailor-made to fight this water analysis challenge. LAR 's ...


    By LAR Process Analysers AG

  • Effects of mixing on chloramination process

    According to a recent study more than 90 percent of water treatment plants utilizing chloramination for distribution system residuals indicate a certain level of dissatisfaction toward the process performance. One factor that may lead to such dissatisfaction is the inadequacy of mixing when ammonia is added to chlorinated water. If mixing is not instantaneous and uniform, the actual chlorine to ...


    By IWA Publishing

  • Analyzing Risk in Wastewater Process Design: Using Monte Carlo Simulation to Move Beyond Conventional Design Methods

    Because there are many variables and uncertainties that can affect the performance of wastewater processes, conventional design methods, which analyze uncertainties in relative isolation, do not always provide an adequate analysis of the risks in a design, including their probability and sensitivity to other variables. A more robust risk analysis method for complex systems is modeling using a ...

  • Controlling the addition of Chlorine into a Process

    There are several methods for controlling the addition of chlorine into a process. These methods include flow proportional injection, ORP (oxidation reduction potential) or a residual chlorine analyzer. Each method measures a different process characteristic. Depending on the specific type of process being controlled, there generally is a best choice for controlling the injection of either ...


    By Walchem, Iwaki America Inc.

  • Assessing performance of on-line nitrate analyzers

    Traditionally, activated sludge processes were designed to remove organics and suspended solids from wastewater. The justification for including nitrogen control in wastewater treatment facilities began with the need to protect receiving waters from the increasing problem of eutrophication and hypoxia (low levels of dissolved oxygen in bottom waters, generally less than 2 mg/l). One of the ...

  • Hydrogen Chloride Analyzer (HCl, H2O)

    LGR's Hydrogen Chloride Analyzer (HCl, H2O) provides sensitive measurements of HCl in ambient air or in industrial process flows (e.g., coal and cement exhaust streams) with extremely high precision and sensitivity. No longer do you have to spend a lot of money or wait a long time to measure HCl with extremely high sensitivity – LGR's HCl Analyzer provides measurements every second with ...

  • Sulfur Compounds Analyzer MEXA-1170SX

    The MEXA-1170SX is a continuous gas analyzer for sulfur compounds existing in engine emissions. It can measure SO2 concentration and the amount of total reduced sulfur compounds (TRS), such as H2S, separately. It can also measure the total sulfur compounds (TS) that contains both gaseous compounds and liquid compounds in PM, such as SO3. By utilizing ultra-violet fluorescence (UVF) method and ...


    By HORIBA Europe GmbH

  • LAN Connectivity for Modern Process Instruments

    Process instruments such as gas analyzers are data sources, which feed a multitude of users. In general,the instruments provide these data analog or digitized through an RS232 interface. However, the datatransfer by this interface has to be located close to the controlling PC, because RS232 is designed forshort distances only. Beyond, the PC has to be dedicated and opts as master. With a ...


    By ECO PHYSICS INC.

  • Natural Gas Processing Case Study

    The Customer The Company is an exploration and production company that builds natural gas reserves through the acquisition and development of oil and gas assets across the U.S. They are one of the largest producers of natural gas in the Nation. The Process The Company uses multiple scrubbers to clean out the impurities of the natural gas that they ...

  • Air Dispersion Models - Models can be used to aid in demonstrating environmental compliance, analyzing process changes and evaluating the impacts of accidental releases

    Air dispersion models are used to estimate the downwind concentration of pollutants emitted by various pollution sources such as industrial facilities and regional public traffic. Dispersion models play an important role in the industrial and regulatory communities. They are typically used to demonstrate compliance with National Ambient Air Quality Standards as part of new source review, ...


    By Trinity Consultants

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you