process analyzer spectrometer Articles

  • Applications of a Portable Gas Spectrometer

    In the realm of natural gas processing, enterprises don’t always find it economical to send products back to the lab and wait for test results. Being able to perform on-the-spot, highly accurate compositional analysis with gas chromatography equipment can reduce operational costs and help companies determine on-the-spot accurate gas levels in a natural gas stream. ...


    By Envent Engineering Ltd

  • A novel spectrometer design for process and handheld infrared spectral measurements

    Introduction Infrared spectroscopy offers many unique advantages for measurements within an industrial environment. Historically, the technique has been used for a broad range of applications from the composition of gas and liquid mixtures to the analysis of trace components for gas purity analysis. In cases where a well-defined method of analysis is involved, such as the measurement of ...


    By CIC Photonics, Inc.

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics, Inc.

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics, Inc.

  • Leak detection in semiconductor fab gas processes

    Problem Statement Often times in semiconductor fabs moisture levels are monitored to ensure that products aren’t damaged by excess moisture in the process. If there are above normal levels of moisture, pinpointing the source of that moisture can be difficult. The moisture could be evolving from impurities in gas tanks or leaks in the sampling lines. One way to avoid downtime ...


    By CIC Photonics, Inc.

  • Get Comparable ASTM/EN Data for Biodiesel Blend Measurements While Saving Time and Money using Portable IR Analyzers

    Both EN 14078 and ASTM D7371 methods for measuring the percent biodiesel in diesel fuel use infrared analysis as the analytical method and are based around using an FTIR spectrometer which has the capability to do a multitude of analyses besides the biodiesel in diesel measurement. This is great for a laboratory where various biofuels measurements are required. However, if the only measurement ...


    By Spectro Scientific

  • Case study - Cost-saving solutions using Sievers InnovOx TOC analyzers - optimizing organic loading

    Cost Concern  A company’s inability to recognize real-time organic loading changes in their wastewater treatment plant could result in excessive charges from the local water utility. Company Challenge A production facility located in the U.S. Midwest currently controls the organic loading in their wastewater’s chemical treatment ...


    By GE Analytical Instruments

  • Texas Instruments - A Novel Separation Technique for the Analysis of Trace Levels of Atmospheric Contaminants in Inert Semiconductor Process Gases

    A NOVEL SEPARATION TECHNIQUE FOR THE ANALYSIS OF TRACELEVELS OF ATMOSPHERIC CONTAMINANTS IN INERTSEMICONDUCTOR PROCESS GASES J. Scott McWilliams, Alan Johnson, Charlene Long, Jeremiah D. Hogan*Texas Instruments, Inc.Dallas, TX 75265 Low ppb detection limits for contamination in cylinder gases have been achieved with gas chromatography using a modified gas ...


    By Environics, Inc.

  • Degradation of malachite green by dielectric barrier discharge plasma

    Oxidative decomposition of aqueous organic pollutant malachite green (MG) was studied in a dielectric barrier discharge reactor operated under ambient conditions. Total organic carbon content analysis confirmed the mineralization of the pollutant leading to the formation of carbon dioxide, which was confirmed by an infrared analyzer. Typical results indicated that the degradation rate increases ...


    By IWA Publishing

  • airmoTWA: New Expert System for GC-FID/MS

    Chromatotec has developed the first TRAP-GC-FID/MS designed for continuous monitoring of Volatile Organic Compounds (VOCs), inorganic molecules and permanent gases. In addition to the mass spectrometer (MS), this system encompasses the same trap, thermo desorption and separation technologies as airmoVOC analyzers (current mCERTS approved GCs analyzers). For VOCs analysis, the Flame Ionization ...


    By Chromatotec Group

  • Boiler mass spec diagnostic testing case study

    CK Environmental was retained by Ze-Gen, to conduct a diagnostic emissions test program on their pilot plant in New Bedford, Massachusetts. Ze-gen is a leading developer and integrator of waste gasification technology which converts construction and demolition waste (C&D) and municipal solid waste (MSW) into near zero-emissions syngas and electrical energy. The ...


    By CK Environmental, Inc.

  • Industrial applications – Air analysis in clean air room - Case study

    Context & Challenges To ensure people’s safety and a good repeatability of industrial process, the analysis of ambient air is crucial. Especially, electronic boards are produced in clean air room by complex lithographic process using very reactive chemicals. The nature and concentration of volatile compounds can be different depending on the chemical process and can also vary ...


    By Chromatotec Group

  • Effective elimination – Case Study

    The LDS 6 laser diode spectrometer supports the effective, safe, and environmentally friendly elimination of odorous gases. Applications in the oil and gas industry are exactly the type of challenge the LDS 6 laser diode process gas analyzer was designed for: sites where high performance and ease of use rank on a par with increased productivity and safety. Those were the requirements of a ...

  • European On-Line Particle Mass Spectrometry

    An international workshop on European On-line Particle Mass Spectrometry (PMS) was held 29th-30th of November 2005 at the JRC in Ispra, Italy. The main goals of the Workshop were: 1) To get together all European scientists involved in the field of PMS 2) To review the latest scientific progress on the field of PMS, with particular emphasis on:a. New instrumentationsb. Data analysisc. ...


  • Application note issue #5 - Cement Analysis August 2017

    Cement analysis using FP program (Fundamental Parameters) Cement is a blend of several minerals. It is critical to control the elemental composition and properties such as strength, setting, time and color. ED-XRF is being used to analyze the raw components, raw meal, clinker, and the final cement product (Na, Mg, Al, ...


    By Xenemetrix Ltd.

  • Measuring IR Light and Near-IR Light

    Infrared (IR) light emits a broad range of non-visible wavelengths in the electromagnetic spectrum. Applications for infrared, including near-infrared, are defined by the respective IR bands during output. For example, LIDAR (Light Detection and Ranging) equipment uses 1,000 nm and 1,550 nm IR bands while surveying an area. In the military sector, 850 nm, 1,060 nm and 1,500 nm (and up) are used ...


    By Larson Electronics LLC

  • A Remote Automated Optical Field Sampling System based on the UniSpec-DC equipped with a Wireless System

    For remote locations, a reliable and repeatable field sampling method is needed for monitoring ecosystem processes for various scientific reasons (e.g. ground truthing, link vegetation indices to ecophysiological variables) (Claudio et al., in press; Fuentes et al., in press, Cheng et al., in press). To ensure that the data are collected continuously, and to collect the data during severe weather ...


    By PP Systems

  • New ASTM Test Method Offers Quick and Easy Oil and Grease Measurement for Water and Soil Samples

    Onsite Field Measurement of Oil and Grease A quick and easy field analysis method for determining oil and grease concentration levels is important for both offshore oil platforms and soil remediation sites.. Prior to the Montreal Protocol, infrared (IR) analysis using Freon as an extraction solvent was a widely used field and laboratory method. In 1999, the U.S. EPA promulgated Method 1664A ...


    By Spectro Scientific

  • Waste Fuel Case History

    The Customer The company engages in the design, manufacture, and sale of machinery for decomposing petroleum-based materials. The company uses microwave technology for recovering hydrocarbons and fossil fuels from sources, such as tires, oil shale, capped wells, coal, automotive shredded residue, municipal solid waste, shale deposits, and waste oil streams. The ...

  • Efficient removal of Cu(II) and Pb(II) heavy metal ions from water samples using 2,4-dinitrophenylhydrazine loaded sodium dodecyl sulfate-coated magnetite nanoparticles

    This study reports on synthesis of a new nanoadsorbent for efficient Cu(II) and Pb(II) ions removal from water samples. In this regard, magnetite nanoparticles have been modified with 2,4-dinitrophenylhydrazine. The synthesized adsorbent has been fully characterized using scanning electron microscope, X-ray diffractometer, Fourier transform infrared spectrometer, and Brunauer, Emmett, and ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you