process water monitoring Articles

  • 10 Reasons why you should continuously monitor low temperature and liquid chemical sterilants for worker safety

    1. Sterilant chemicals are highly toxic Low temperature and liquid chemical sterilants are designed to kill all microorganisms including resistant spores and if they were not toxic, they would not be effective in sufficiently high concentration to destroy all microbial life including the chemically resistant sporicidal forms of certain ...


    By ChemDAQ, Inc.

  • Flow Rate Measurement in Full Pipes Using the Transit Time Method

    Particularly in large diameters the relevance of water volume measurement is growing. The challenge with cooling water or fresh water processes is to generate accurate flow recordings or to document and to control individual consumptions and withdrawal quantities. Flow detection, however, particularly in large diameters is highly demanding. In such cases the transit time measurement thanks to its ...


    By NIVUS GmbH

  • How a contract research lab advanced its polymer characterization capabilities

    Realizing the Advantages of Ultra-High-Performance Size Exclusion Chromatography Compared to GPC Intertek is a global provider of quality and safety services designed to help businesses improve products, assets and processes, overcome market constraints and reduce risks. From auditing and inspection, to testing, training, and certification, Intertek enables customers to meet end ...


    By Waters Corporation

  • The climb to the top

    Back in the late 1980’s when market drivers created the cost-effective option of using above-ground circular tanks for industrial activated sludge processes, there were some early valuable lessons for both aeration equipment manufacturers and plant operators. As production plants got away from in-ground basins, one of the more simple innate operational checks became more challenging; ...


    By KLa Systems, Inc.

  • Oil Sampling Best Practices (Part 2)

    Understanding Dynamic Particle Equilibrium in Closed Loop Systems Dynamic Equilibrium Condition (DEC) is defined as a steady state condition where the normal wear rate in a machine results in no net gain or loss of particles. ...


    By Spectro Scientific

  • Monitoring the fate of fluorescing substances recycled in ultrafiltration process backwash water

    The fate of fluorescing substances during the recycling of membrane backwash water (MBWW) ahead of coagulation, flocculation and sedimentation (CFS) with ultrafiltration (UF) membranes has been investigated. Bench-scale UF membranes were used to generate MBWW from a CFS-treated surface water containing 21 mg/L dissolved organic carbon (DOC) registering a 0.95 cm–1 UV254 absorbance that ...


    By IWA Publishing

  • Oil on Water Monitoring

    Northern Ireland Water operate a number of potable water plants around Lough Erne and the River Derg, these waterways are extremely popular with tourists and are used for pleasure crafts of various sizes, from jetskis to fully fitted 6 berth cruisers. These watercraft create an ongoing risk of floating oil from poorly maintained engines, as the watercraft have access to within 10 metres of the ...


    By Partech (Electronics) Ltd.

  • Monitoring Phenol in Water

    The Situation A plant located in the eastern United States manufactures phenolic resin for applications in plastics molding. This plant uses well water for cooling its reaction process and then discharges the water into a local creek. A leak in the reactor and associated cooling equipment would cause phenol and phenolic compounds to contaminate the cooling water. Such a leak could ...

  • Monitoring Hydrocarbons in Bilge Water

    The Situation Various processes onboard ships, such as machinery wash-down, maintenance, and leakage generate oily wastewater. This contaminated water flow collects in the bilge of the ship. Marine diesel, lubricating oils, grease, as well as garbage may be present in bilge water. The bilge water is discharged overboard, with oil and grease concentrations in the discharged water limited ...

  • Understanding and Monitoring Hydrocarbons in Water

    Untitled Document 1. Introduction Oil contamination continues to be a very hot topic, due largely in part to recent catastrophic events with shipping ...


    By Arjay Engineering Ltd.

  • Tylosin abatement in water by photocatalytic process

    The photocatalytic degradation of a macrolide (tylosin) has been studied using immobilized titanium dioxide as photocatalyst in a laboratory reactor under UV illumination (365 nm). The degradation of the antibiotic and of the reaction intermediary product was monitored by UV spectrophotometry and HPLC. Three photocatalysts (P25 from Degussa and PC105 and PC500 from Millenium) immobilized on glass ...


    By IWA Publishing

  • Unique technology for monitoring piped water

    INTELLITECT WATER has launched a unique, highly innovative drinking water monitoring technology that will revolutionise the delivery of drinking water. The new technology monitors the quality of water in pipeline distribution networks and for the first time provides reliable data to protect the integrity of the water quality, to enhance customer satisfaction and to improve operational efficiency. ...


    By Intellitect Water Ltd

  • Groundwater Monitoring Water Solids Removal

    Industrial Waste Water Treatment Success Stories Groundwater Monitoring Colloidal Solids Removal Effective Ground Water Solids Removal The ground ...


    By Integrated Engineers Inc.

  • Implementation of a process internal control to monitor the performance of real-time PCR assays for the detection of Vibrio cholerae in water

    The process control utilised in this study was an Escherichia coli (E. coli-GFP) strain carrying a chromosomally integrated copy of the green fluorescent protein (gfp) gene of the jelly fish Aequorea victoria. Application of the process control involved spiking samples with the E. coli-GFP containing cells and detecting ...


    By IWA Publishing

  • Automatic Sludge Blanket Level Detector: Monitor & control for effective, efficient processing

    Reducing energy consumption at municipal and industrial plants is, increasingly, a priority. Markland Specialty Engineering Ltd., designing and manufacturing process control instrumentation since 1967, helps achieve this important goal with its Automatic Sludge Blanket Level Detector. By helping facilities reduce waste - reducing unnecessary water, chemical or energy use, and unnecessary ...

  • Online Process Analyzer Installed at F.J. Horgan WTP to Monitor Chloramination

    Construction was completed on the City of Toronto's F.J. Hor-gan Water Treatment Plant in 1979, more than 60 years after chloramine had first been used to disinfect drinking water in an Ottawa plant. By then there was little debate about the benefits of chloramination and it was incorporated into the new plant's design as part of the disinfection process. Chloramine is more stable than free ...

  • Modular treatment system neutralizes process water

    A self-contained pH control and monitoring sys- tem for ready mixed operations yields clean water for recycling or permitted discharge to the environment. Fortrans' Model 5000S uses car- bon dioxide gas to neutralize high-pH process water, offering precise alkalinity monitoring and control of water in pits, settling basins and other containment areas, as it lowers total suspended solids. Designed ...


    By Fortrans, Inc.

  • Degradation of azo dyes in water by Electro-Fenton process

    Abstract The degradation of the azo dyes azobenzene, p-methyl red and methyl orange in aqueous solution at room temperature has been studied by an advanced electrochemical oxidation process (AEOPs) under potential-controlled electrolysis conditions, using a Pt anode and a carbon felt cathode. The electrochemical production of Fenton's reagent (H 2O 2, Fe 2+) allows a controlled in situ generation ...


    By Springer

  • Biofilm control strategies in industrial processing waters

    Bacterial biofilms cause a number of serious problems for industrial fluid processing operations. Mechanical blockages, impedance of heat transfer processes and microbially induced corrosion result in billions of dollars of losses each year. In engineered systems, such as cooling water systems, food processing, and other industrial applications possible risk to public health and product spoilage ...

  • Efficiency Improvements in Water Treatment Process: Aqwest-Bunbury Water Board

     Aqwest-Bunbury Water Board has introduced a range of cleaner production measures designed to improve the overall efficiency of its water treatment plants. Background Aqwest, the operating arm of the Bunbury Water Board, supplies water to approximately 12,000 service connections for the 30,000 residents of the town of Bunbury, Western Australia, 180km south of Perth. ...


Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you