The Process: The Municipality of the District of Lunenburg in Whynott's Settlement, Nova Scotia added a septage receiving station to their landfill site. Part of the treatment train is a chlorinated duplex vertical turbine pump station delivering effluent from the sludge processing facility to a field of spray nozzles for dispersion. The pump station has two points of discharge and the twin ...
Dwr Cymru Welsh Water has benefitted from the unique 'Pumped Volume' feature built into Pulsar's Quantum 2 Pump Station Controller; identifying a flow problem within a pumping station network without the need for expensive Magflow meters. Once the issue was resolved, pumped volume through one of the stations was reduced by 88% , with substantial associated energy saving. Equipment used: ...
The design of the equipment components of a flow pump system for the measurement of solute (effluent) breakthrough curves from soil columns is described. In addition, the performance of the system in terms of the effects of equipment components and temperature on measured differential pressure fluctuations across soil specimens is illustrated. The flow pump for the system provides continuous flow ...
FPI Mag installed in pipe. Water and wastewater utilities rely on accurate flow measurement for important process controls. These may include recycle streams, chemical dosing systems, and other operational functions. In addition, regulators require utilities to measure certain flows, such as treatment plant influent and effluent and potable water pumping. Accurate flow measurement is also ...
A Texas based company with waste management sites around North America have installed electrical generation plants at various locations that use methane collected from the waste. The daily operation of these sites include the management of the leachate, a liquid waste by-product of decomposition, and the collection of gas for electricity production. This is typically carried out at multiple wells ...
Many of the VFDs used by the water and wastewater industry are approaching 20 years old. With careful maintenance throughout this period, the drives will still be giving good service. But there comes a point in any drive's life cycle where the decision has to be taken: do you replace, upgrade or retrofit? But which is best and when is each relevant? This article explains the choices and the ...
The Dutch province of Flevoland lies metres below sea-level. That’s why rain and seepage need to be removed from the polder, some 6 metres up. And that’s the reason Flevoland is drained continuously by seven huge pumping stations. The quantity of energy involved in this is as great as the energy consumption of 4,000 households. Water Board Zuiderzeeland has launched the ‘Energy ...
BBA Pumps has completely updated its assortment of accessories for mobile pumps. Information has been made more relevant with new technical data and product videos. In addition, new products have been added to further optimize your pump system. Pipes for Water Transport A clear overview of discharge pipes and header pipes from small to large with quick release couplings compatible with ...
Significant energy savings can be achieved by optimizing pump operating efficiency. Measuring the exact pump performance with crude oil under realistic conditions in the field is the first step towards improving the pump efficiency in the future. About 20 billion barrels of crude oil were transported through pipelines in 2015. Around the world, there are over one million kilometers of crude oil ...
Client Water Board Zuiderzeeland Country The Netherlands Watch the video Watch the video in which Albert Koffeman of Water Board Zuiderzeeland explains why they choose Eijkelkamp Soil & Water and NIVUS equipment for their flow monitoring. The Dutch province of Flevoland lies metres below sea-level. That’s why rain and seepage need to be removed from the polder, some 6 metres up. ...
Address: Cloonamahon, Collooney, Co. Sligo Client: North Western Health Board Engineer/Client Contact Details: Jennings O'Donovan & Partners, Finisklin, Sligo David Kiely, Ph: 071 9161416 Completion Date: March 2001 Population Equivalent: 400 P.E. Value: € 138,392 + Vat BMS Design Details: BMS designed and manufactured the entire treatment system to the consultants final effluent ...
Metering pumps with operating pressures of up to 150 psig (pounds per square inch gauge) can create unwanted pressure pulsations within a piping system – a real problem in applications such as filling, mixing and spraying that require a combination of a metering pump’s accuracy and a continuous flow. But the issue can often be addressed with Pulsation Dampeners.The Pulsation Dampeners, usually ...
In this article we show you how to conduct measurements with our new portable GT5000 Terra FTIR gas analyzer. Watch the video below to learn how to take your gas analyses to the next level: How to use GT5000 Terra Gasmet FTIR Gas Analyzer Getting Familiar with The GT 5000 Terra Before detailing how to use the device, it is important to be aware of certain features. First, on the front side of ...
The performance of a pump is influenced when it handles viscous fluids such as crude oil. For the configuration and design of pumps, this is key. In the industry, pump performance curves are developed by testing with water at temperatures around 25°C and corrected to a specific gravity of one. Engineers use this standard so that they have comparable measurement values around the world. The ...
This article tells you how to perform low flow groundwater sampling using a portable, surface-mounted pump with no decontamination required before each use and no chance of cross contamination between wells. An inertial lift pump moves a dedicated (stored in the well) pumping tube rapidly up and down. A one-way valve on the bottom admits water on the down stroke and retains water on the ...
When water flows through a defined area such as a pipe or the inlet / outlet port of a pump, the flow rate is simply the measurement of how much water passes through an "imaginary plane" in a certain amount of time. This method of defining flow rate is so basic that it is adopted by engineers and equipment manufacturers everywhere for virtually all products in the water industry including pumps, ...