radiation protection dosimeter Articles

  • Calibration and characterisation of extremity dosimeters

    The increasing use of radiation in the medical field is providing great advances in health improvement. However, these techniques can generate an increase in the number of professionals exposed to radiation. The Brazilian authorities (Brazilian Nuclear Energy Commission ? CNEN) have imposed the monitoring of specific body parts of professionals. One of these obligations is the monitoring of the ...


    By Inderscience Publishers

  • Evaluation of occupational radiation exposure of cardiologists in interventional radiography in Mashhad CATHLABs

    Several studies have revealed that interventional radiography procedures performed in cardiology departments are high dose techniques. In this study, effective dose of cardiologists working in hospitals Catheterisation Laboratories (CATHLABs) in Mashhad city have been measured during Coronary Angiography (CA) and Percutaneous Transluminal Coronary Angioplasty (PTCA) procedures. In order to ...


    By Inderscience Publishers

  • Assessment of the environmental outdoor gamma radiation levels in Sao Paulo City

    Dose values from natural radiation sources in several sites of Sao Paulo City were assessed from environmental outdoor gamma radiation levels, by using CaSO-4:Dy thermoluminescent dosimeters. Twelve monitoring stations were placed in different regions of the town including both urban and outskirts areas and the measurements were carried out quarterly and ...


    By Inderscience Publishers

  • Development and production of holders for extremity detectors

    The objective of this paper was to develop and produce holders for thermoluminescent detectors for use in interventionist radiology and nuclear medicine. To obtain the value of Dose Equivalent for Extremities, a dosimetry of extremities was done. The holders must have characteristics which are adequate for their intended use. The detector element used in the holders was the LiF:Mg,Ti (TLD-100) ...


    By Inderscience Publishers

  • Noise Measurement

    Definitions Threshold and criterion levels The threshold level is the A-weighted sound level at which a personal noise dosimeter begins to integrate noise into a measured exposure. For example, if the threshold level on a sound level meter is set at 80 decibels (dB), it will capture and integrate into the computation of dose all noise in the employee's hearing zone that equals or exceeds 80 dB. ...


  • Measurement uncertainty

    The IAEA/WHO Network, through Secondary Standards Dosimetry Laboratories (SSDLs) designated by the Member States, provides a direct linkage of national dosimetry standards to the international measurement system (SI, for Système International). Through the proper calibration of field instruments by the SSDLs, these measurements are traceable to the Primary Standards Dosimetry Laboratories (PSDLs) ...