  • Real-time process dynamics monitoring in Anammox reactors

    Process dynamics in Anammox systems were evaluated through continuous monitoring of pH, oxidation reduction potential (ORP) and conductivity in two separate newly started-up sequencing batch reactors, one seeded with an enriched Anammox sludge and the other seeded with mixed activated sludge. The pH and ORP profiles exhibited characteristic patterns depending on the process dynamics during early ...


    By IWA Publishing

  • Real-Time Membrane Fouling Monitoring

    The Port Hueneme Water Agency (PHWA) has been operating a municipal drinking water treatment plant designed to be a Brackish Water Reclamation Demonstration Facility. The facility consists of 3 separate side-by-side full scale systems or trains, each representing a major membrane separation process: nanofiltration (NF), reverse osmosis (RO) and electro dialysis reversal (EDR). Both the NF and RO ...


    By MASAR Technologies, Inc.

  • Real Time Measurments of Acetylene in Ethylene Manufacturing Process

    Keywords Tunable Diode Laser, Wavelength Modulation Spectroscopy, Analyzer, Acetylene, Ethylene, Acetylene Converter Abstract The analyzer, based on near infrared Tunable Diode Laser Absorption Spectroscopy (TDLAS), was developed for the measurement of acetylene in process streams. Measurements of acetylene were made as under laboratory conditions and in ...

  • Real-Time Control Optimizes Extended Aeration Processes

    The population of Hillsborough County, Florida has doubled since the Valrico advanced wastewater treatment plant (AWTP) was built in 1990 to treat the sewage of several small communities west of the City of Tampa. When it began operation, the Valrico AWTP capacity was only 4 MGD; small when compared to Tampa's 96 MGD Howard F. Curren AWTP located not far to the east. But Valrico serves as a very ...

  • BLOOM – Real-Time Monitoring Brief - Case Study

    PeCOD® is a patented technology that can determine COD by measuring photocurrent charges originating from oxidation of the organic contaminants present in a water sample. Three PeCOD® analyzer units were implemented at three different facilities, representative of key food and beverage sub-sectors–a winery, a bakery and a brewery–to undertake “real-time” ...


    By MANTECH

  • Real-time monitoring for reduced chemical maintenance

    We are pleased to be featured in this month’s American Laundry News digital edition, together with our customer Walter E. Nelson, a janitorial, paper and chemical distributor in the Northwest that provides a wide range of laundry products and equipment. Jerry Roberts, of Walter E. Nelson, explains how he has experienced a significative ...

  • Aerzen Offers Plant Monitoring in Real Time

    Delta Real Time MonitoringFollowing extensive field tests, Aerzener Maschinenfabrik can now offer its permanent machine monitoring system “Delta Real Time Monitoring” for the entire delivery programme. With this real time system, which provides a very high level of security, Aerzen is able to satisfy requests from plant operators for high-quality process sequences. If the vibrations ...

  • Study on the value of real-time reporting

    A recent independent study conducted by the Aberdeen Group indicates that businesses using real-time performance reporting (like the reporting functionality included in the Intelex EQH&S Management Systems) realize greater success in relation to equipment effectiveness, production yield, and profit margins.According to Matthew Littlefield, a senior researcher at Aberdeen Group, “best-in-class ...


    By Intelex Technologies Inc.

  • Real time odour monitoring: odour abatement monitoring using electronic noses.

    The equipment implemented to reduce odour emissions is designed with effectiveness in mind. However, some operating conditions may reduce that effectiveness without an industrial site being able to detect this quickly. Processes that most of the time have low odour emissions may become, under certain weather conditions, a major nuisance source. An electronic nose system can detect odour before ...


    By Odotech Inc.

  • 4700 Sampler Industrial Park Wastewater Monitoring - InfraServ Knapsack, Germany - Case Study

    The Model 4700 Automatic Refrigerated Sampler from Teledyne Isco, Inc. is used for water quality monitoring at an industrial park operated by InfraServ Knapsack, Germany InfraServ Knapsack InfraServ GmbH & Co. Knapsack KG is the company that operates the Chemical Industrial Park Knapsack. The site is situated in Huerth, south of Cologne in Germany. The park is divided into ...


    By Teledyne Isco

  • Real-time monitoring and forecasting of odor after dewatering in wastewater treatment

    A real-time odor monitoring system was developed to evaluate and predict odors levels of dewatered solids generated by the District of Columbia Water and Sewer Authority’s (DCWASA) advanced 370 mgd wastewater treatment plant (WWTP) in Washington, DC. Each year, DCWASA generates over 400,000 wet tons of biosolids and recycles these biosolids by applying them to over 20,000 acres of agricultural ...

  • Develop a `real-time` air emissions monitoring strategy for your facility

    To improve air quality, states and localities are requiring more intense 24/7 monitoring of listed air pollutants from hydrocarbon processing facilities. Affected facilities must develop reliable and accurate environmental data management systems for reporting purposes. In this case history, the BP Texas City site (a refinery and chemicals plant) successfully implemented a real-time environmental ...


    By Wood Group Mustang, Inc.

  • Implementation of a process internal control to monitor the performance of real-time PCR assays for the detection of Vibrio cholerae in water

    The process control utilised in this study was an Escherichia coli (E. coli-GFP) strain carrying a chromosomally integrated copy of the green fluorescent protein (gfp) gene of the jelly fish Aequorea victoria. Application of the process control involved spiking samples with the E. coli-GFP containing cells and detecting ...


    By IWA Publishing

  • Operational Intelligence: The ability to monitor resources and operations in real-time

    The terms “knowledge management” and “learning organizations” were but a few of the mantras often heard in the business world during the mid to late 1990’s. And, of course, there is the old adage of “Knowledge is Power”.During this period and even today, various companies and organizations are actively engaged in identifying what they term as their core critical skills and knowledge. One ...


    By VisionMonitor Software, LLC

  • Radio Solution brings real-time monitoring benefits for water supplier

    Introduction of wireless data collection and analysis improves leak detection and water supply efficiency Companies whose business is the delivery of water to consumers, do not only have a responsibility to provide high quality drinking water to both domestic and industrial users, but also to ensure that it is done so economically and reliably. The WLV association ...

  • Real Time TOC Analysis in Steam and Condensate

    Executive Summary Steam in petro/chemical plants could be contaminated with hydrocarbons (TOC = Total Organic Carbons) from various sources. In any case this is a sign for defects in the process, whether it they occur in the heat exchanger, the blow down vessel, the condensate recovery or other parts of the system. Conventional solutions to monitor such contaminations use TOC- ...


    By JCT Analysentechnik GmbH

  • Real-time TOC tightens effluent control at Greencore

    A food manufacturing facility in Selby has installed a new continuous TOC (Total Organic Carbon) monitor, ‘the BioTector’ which has dramatically improved the site’s capability to refine and improve the plant’s wastewater treatment process. As a result the plant is better able to quickly respond to changes in the influent. Greencore Foods is a leading player in the food ...


  • Improved real-time data anomaly detection using context classification

    The number of automated measuring and reporting systems used in water distribution and sewer systems is dramatically increasing and, as a consequence, so is the volume of data acquired. Since real-time data is likely to contain a certain amount of anomalous values and data acquisition equipment is not perfect, it is essential to equip the SCADA (Supervisory Control and Data Acquisition) system ...


    By IWA Publishing

  • Control Algae and Improve the Water Quality in Waste Stabilization Ponds

    Due to population growth, accelerated urbanisation and economic development, the quantity of waste water generated is increasing globally. Mainly in low-income areas, a large proportion of the waste water is discharged directly in the environment. When the waste water is treated, the treatment plants may not remove certain pollutants that can have a negative impact on the people and ecosystem. ...


    By LG Sonic

  • [Technical Paper] Biomass Evolution in Full-Scale Drinking Water Filters

    After nearly two-years of work, we could advance our understanding of ATP measurement in drinking water biofilters. I will describe some of the background and key results from the study below – more information is provided in the Journal AWWA December 2016 article. Background of the ...


    By LuminUltra Technologies Ltd.