real-time water analysis Articles

  • Real Time TOC Analysis in Steam and Condensate

    Executive Summary Steam in petro/chemical plants could be contaminated with hydrocarbons (TOC = Total Organic Carbons) from various sources. In any case this is a sign for defects in the process, whether it they occur in the heat exchanger, the blow down vessel, the condensate recovery or other parts of the system. Conventional solutions to monitor such contaminations use TOC- ...


    By JCT Analysentechnik GmbH

  • Real-Time Membrane Fouling Monitoring

    The Port Hueneme Water Agency (PHWA) has been operating a municipal drinking water treatment plant designed to be a Brackish Water Reclamation Demonstration Facility. The facility consists of 3 separate side-by-side full scale systems or trains, each representing a major membrane separation process: nanofiltration (NF), reverse osmosis (RO) and electro dialysis reversal (EDR). Both the NF and RO ...


    By MASAR Technologies, Inc.

  • A real-time operation of the Three Gorges Reservoir with flood risk analysis

    Risk analysis is essential to reservoir operation. In this study, a new analysis for reservoir operation is proposed to enhance the utilization rate of the flood water from the Three Gorges Reservoir (TGR) during the flood season. Based on five scenarios of hydrology forecasting with the adaptive neuro-fuzzy inference system (ANFIS), a multi-objective optimum operation was implemented ...


    By IWA Publishing

  • Get more out of Water Resources Engineering Models

    The effort required to develop water resources engineering models can be significant. But once developed, in many instances the models are only evaluated for a limited, or a single set of conditions. The results and predictions obtained from these evaluations are the ones used in design, presented in reports and conveyed to decision makers and the public. This approach might serve ...


    By XP Solutions

  • The Internet of Water Is Saving Lives While Battling Pollution

    The Problem A condition known as Legionnaires' disease has made headlines after it killed a dozen people in Flint, Michigan in 2014 and 2015 and sickened hundreds in  ...


    By Griswold Water Systems

  • BLOOM – Real-Time Monitoring Brief - Case Study

    PeCOD® is a patented technology that can determine COD by measuring photocurrent charges originating from oxidation of the organic contaminants present in a water sample. Three PeCOD® analyzer units were implemented at three different facilities, representative of key food and beverage sub-sectors–a winery, a bakery and a brewery–to undertake “real-time” ...


    By MANTECH

  • Real-time Total Microbial Measurement For Water Distribution Systems

    A well-managed water distribution system is essential for maintaining a healthy water supply. The World Health Organization, the directing and coordinating authority on health (World Health Organization, 2008), has compiled the Water Safety Plan which reflects this. With over 2.3 million deaths per year caused by water born diseases (Davidson, et al., 2005), safeguarding water systems is of ...


    By LuminUltra Technologies Ltd.

  • Real-time Water Monitoring Solution for Queensland case study

    Customer: ConfidentialApplication: Water monitoringBackground: Department of Environment and Heritage Protection (DEHP) are responsible for managing the health of the environment to protect Queensland’s unique ecosystems, including its landscapes and waterways, as well as its native plants ...


    By Ecotech Pty Ltd

  • Real-time TOC tightens effluent control at Greencore

    A food manufacturing facility in Selby has installed a new continuous TOC (Total Organic Carbon) monitor, ‘the BioTector’ which has dramatically improved the site’s capability to refine and improve the plant’s wastewater treatment process. As a result the plant is better able to quickly respond to changes in the influent. Greencore Foods is a leading player in the food ...


  • Radio Solution brings real-time monitoring benefits for water supplier

    Introduction of wireless data collection and analysis improves leak detection and water supply efficiency Companies whose business is the delivery of water to consumers, do not only have a responsibility to provide high quality drinking water to both domestic and industrial users, but also to ensure that it is done so economically and reliably. The WLV association ...

  • Stop the hit and miss in coagulation-flocculation: AppliTek’s charge density analyzer to reduce polymer dosing

    Specialist manufacturer AppliTek NV has the pleasure to announce its latest analytical solution, called EZ-Charge®, for reducing the potentially skyrocketing costs that come with controlling the amount of suspended solids in waste water treatment. The novel water analyzer has been developed in cooperation with AQRatio (Germany), a company specialized in sewage sludge analysis and control. ...


    By AppliTek NV

  • Optimizing Wind and Solar Power in Africa

    Editor's Note: The following is a news release authored by Julie Chao and issued by Lawrence Berkeley National Laboratory on April 5, 2017 To meet skyrocketing demand for electricity, African countries may have to triple their energy output by 2030. While hydropower and fossil fuel power plants are favored approaches in some quarters, a new assessment by the Department of Energy’s Lawrence ...


    By Smart Grid Observer

  • Online Chemical Oxygen Demand for Treatment Optimization - Case Study

    A wide variety of products are made in the chemical and pharmaceutical manufacturing industries, that require large volumes of chemicals, materials, and substances that are used throughout process operations. Waste water from these facilities typically include contaminants, toxins, nutrients, and organic content that presents challenges with regards to treatment. A major UK based chemical ...


    By MANTECH

  • Rapid and specific detection of Salmonella in water samples using real-time PCR and High Resolution Melt (HRM) curve analysis

    A real-time PCR assay combined with a pre-enrichment step for the specific and rapid detection of Salmonella in water samples is described. Following amplification of the invA gene target, High Resolution Melt (HRM) curve analysis was used to discriminate between products formed and to positively identify invA amplification. The real-time PCR assay was evaluated ...


    By IWA Publishing

  • AquaLab Analyzer provides real-time phosphorus measurement in Everglades

    When it comes to ecosystem sustainability, Florida is no backwater. The South Florida Water Management District, which includes the unique Everglades habitat, had a major challenge. The EPA and various governmental authorities have defined limits for many water quality parameters to support a water body’s designated use. Any physical, chemical or biological condition that threatens the designated ...

  • Water analysis

    A complete tap water analysis includes the determination of the pH value, the alkalinity and the total water hardness. Both the pH measurement and the pH titration by means of a standard pH electrode suffer from several drawbacks. First, the response time of several minutes is too long and, above all, the stirring rate significantly influences the measured pH value. Unlike these standard pH ...


    By Metrohm AG

  • Evaluation of real-time PCR for quantitative detection of Escherichia coli in beach water

    The current investigation evaluated the use of real-time polymerase chain reaction (PCR) for quantitative detection of Escherichia coli in marine beach water. Densities of E. coli in 263 beach water samples collected from 13 bathing beaches in Hong Kong between November 2008 and December 2009 were determined using both real-time PCR and culture-based methods. Regression ...


    By IWA Publishing

  • Automated techniques for real-time shipboard determination of dissolved trace metals in marine surface waters

    This review compares methods that are currently employed for shipboard analysis of trace metals in seawater voltammetric, chemiluminescence and colorimetric methods. Instrumentation and methods are described for collecting surface seawater using pumping, with subsequent on-line analysis by stripping voltammetry. The review is illustrated with data for oceanic and coastal distributions of ...


    By Inderscience Publishers

  • Evaluation of DNA extraction methods and dilution treatment for detection and quantification of Acanthamoeba in water and biofilm by real-time PCR

    Acanthamoeba, human pathogens and natural hosts of pathogenic bacteria, may be accurately detected and quantified by real-time PCR if Acanthamoeba DNA are properly extracted and PCR inhibitors are effectively eliminated. However, the optimization of DNA extraction methods has not been reported for Acanthamoeba. This study compared the effectiveness of two DNA extraction/purification methods ...


    By IWA Publishing

  • Optimizing water quality sampling through application of real time ionic concentration regression models

    The Water Resources Management Division of the Department of Environment and Conservation performs routine water sampling to measure the physical and chemical parameters of select water bodies in Newfoundland and Labrador. Ionic concentration parameter measurement is performed during routine water sampling to complement some of the key indicator parameters measured in real time at these select ...


    By IWA Publishing

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you