reverse osmosis element Articles

  • Reverse Osmosis Element Design

    Introduction  TORAY REVERSE OSMOSIS MEMBRANE ELEMENTS are functional membrane elements with excellent quality and high performance developed with the polymer engineering expertise Toray has gained over the years. Toray Reverse Osmosis Membrane Elements are high rejection and high flux RO elements that have been meeting the high level requirements of our customers in many applications: ...


    By Toray Membrane Europe

  • Reverse Osmosis

    The United States Pharmacopeial Convention Inc. (USP) has proposed new specifications for Water for Injection (WFI) and Purified Water (PW). These specifications will include quantitative conductivity, and total organic carbon (TOC) measurements will replace 100-year-old qualitative wet chemistry tests. The impetus behind these changes is to create a means of analysis that is less ...


  • Features of Reverse Osmosis (RO)

    1. Removal of dissolved salts  Reverse osmosis can stably and effectively remove dissolved salts, dissolved organic substances (trihalomethane, its precursors, agricultural chemicals, etc.), and micro fine particles (living germs, dead germs, and many other micro fine particles) from water. Thus it is ideal for a wide area of applications ranging from production of ultra pure water to ...


    By Toray Membrane Europe

  • Reverse Osmosis for WFI and PW

    The United States Pharmacopeial Convention Inc. (USP) has proposed new specifications for Water for Injection (WFI) and Purified Water (PW). These specifications will include quantitative conductivity, and total organic carbon (TOC) measurements will replace 100-year-old qualitative wet chemistry tests. The impetus behind these changes is to create a means of analysis that is less ...

  • Cogenerative seawater reverse osmosis. Part 1: elements characteristics

    This work is a part of an extensive study performed in the area of cogenerative seawater Reverse Osmosis (RO) design, appraisal and rehabilitation. It is concerned with large-scale contiguous seawater RO systems, focusing on the 8040-type membranes of high-flow and high-salt rejection ranging in area from 300 to 400 ft². Seventeen types of membranes are selected between large- and medium-sized ...


    By Inderscience Publishers

  • Industrial reverse osmosis system design

    Reverse osmosis (RO) is currently used in various applications ranging from small, undersink drinking water units to large industrial systems. The technology is widely used and accepted as it removes both dissolved ionic and organic impurities. This article will focus on the reverse osmosis technology in industrial applications and will discuss factors that differentiate industrial RO from ...


    By Agape Water Solutions, Inc.

  • Wastewater Recovery Using Reverse Osmosis

    INTRODUCTION If one were to select a single word describing the most important factor when applying membrane technology to a wastewater application, it would be chemistry. That is not to say that other factors are not important; certainly fluid dynamics and other physical science factors play a major role as well. But it is the chemistry that is so important to success. And it is the ...

  • Seawater feed reverse osmosis preheating appraisal, Part I: leading element performance

    This paper is concerned with the seawater reverse osmosis preheating process, and presents a parametric study of the process. The basic transport equations describing the leading element are exhibited and appraised. The leading element, which governs the whole system performance, is studied and analysed. The incorporated and investigated operating parameters are the feed pressure and the ...


    By Inderscience Publishers

  • Evaluating impact of fouling on reverse osmosis membranes performance

    Abstract Membrane fouling is commonly defined as an undesirable formation of deposits on mem- brane surfaces and it is considered a major problem in most brackish, seawater, and waste water reclamation applications. Depending on nature of the scale and foulant, fouling pro- cesses will lead to decreased membrane fluxes, increased pressures needs, and/or increased permeate conductivity. ...

  • Reverse osmosis: Whether a concern over the removal of minerals or not?

    Reverse Osmosis will generally remove salt, manganese, iron, flouride, lead, and calcium (Binnie et. al., 2002).  Most mineral constituents of water are physically larger than water molecules and they are trapped by the semi-permeable membrane and removed from drinking water when filtered through a RO (AllAboutWater.org, 2004).  Meanwhile, consumers are concerned about the removal of ...


    By IWA Publishing

  • Selecting a pump for sea water reverse osmosis

    Reverse osmosis (RO) desalination has become a significant process used in the purification of water. Selecting the correct pump is a significant step in a well designed and properly operating pumping system. Although the pump is a relatively small part of the overall cost of an RO system, expenses resulting from downtime and inefficiency can quickly diminish the productivity of the RO system and ...


    By Cat Pumps

  • Getting Comfortable With Your Reverse Osmosis Machine

    Introduction Most people who work with an apparatus unlike any in their previous experience approach it with some apprehension. This is common behavior and fits the way most of us approach unfamiliar things. Perhaps you deal with this kind of uncertainty about the reverse osmosis (RO) machine in your dialysis unit. This article is intended to increase your understanding of the machine and how it ...


  • Seawater feed reverse osmosis preheating appraisal, Part II: system performance

    The present work evaluates the seawater feed Reverse Osmosis (RO) preheating system process. In this respect, the basic transport equations, which describe the system elements, are used for determining the performance of the process operating parameters and for assessing the feed preheating process. A seawater membrane, FTSW30HR-380, was used to perform this study. In Part I of the work, the ...


    By Inderscience Publishers

  • Preservation of reverse osmosis membranes with non oxidizing biocides – comparison with SMBS

    Sodium metabisulphite (SMBS) is the current standard preservation chemical used in RO plants during shut down. It is a cheap and efficient preservative, but its tendency to oxidize easily has several drawbacks. The use of a non-oxidizing biocide instead could solve some of the issues currently seen with the SMBS, but little has been reported about membrane compatibility and preservation ...


    By IWA Publishing

  • Reverse Osmosis: How Does It Figure Into a Dialysis Water System?

    Better than 95% of all dialysis centers use water purification equipment to purify water for dialysis. The centerpiece of these water purification systems has become reverse osmosis. In conjunction with sound pretreatment, RO has proven itself to be the safest, most reliable, and most economical method of purifying water for dialysis. Water plays an important, life-sustaining role for dialysis ...

  • Short- and long-term fouling characteristics of reverse osmosis membrane at full scale leachate treatment plant

    This research is focused on characterizing the foulants on a reverse osmosis (RO) membrane taken from a full-scale leachate treatment plant in Thailand. The system consists of a physico-chemical pre-treatment unit and RO system and has been in operation for 2 years. Ferric chloride (FeCl3) was added to the open-jet sedimentation tank at 2.0–2.5 g/l dosage for chemical coagulation. The supernatant ...


    By IWA Publishing

  • Reverse osmosis followed by activated carbon filtration for efficient removal of organic micropollutants from river bank filtrate

    Drinking water utilities in Europe are faced with a growing presence of organic micropollutants in their water sources. The aim of this research was to assess the robustness of a drinking water treatment plant equipped with reverse osmosis and subsequent activated carbon filtration for the removal of these pollutants. The total removal efficiency of 47 organic micropollutants was investigated. ...


    By IWA Publishing

  • Permeability decline in nanofiltration/reverse osmosis membranes fed with municipal wastewater treated by a membrane bioreactor

    Decline in the permeability in nanofiltration (NF)/reverse osmosis (RO) membranes that filtered effluents from a membrane bioreactor (MBR) treating municipal wastewater was investigated in this study. Four different 2-inch spiral-wound NF/RO membrane elements were continuously operated for 40 days. The results showed that the amount of deposits on the membrane surface did not affect the degree ...


    By IWA Publishing

  • Boron removal from brackish water by reverse osmosis and nanofiltration membranes: application of Spiegler–Kedem model and optimization

    Drinking water should contain certain chemicals only in limited quantities. Boron, one of these chemicals which is considered as a threatening compound and is difficult to eliminate from water. The purpose of the research is to study the major role of reverse osmosis (RO) and nanofiltration (NF) process which can contribute to the removal of this inorganic element from brackish water. For this ...


    By IWA Publishing

  • Water Recovery from an Aluminum Can Manufacturing Process Using Spiral-Wound Membrane Elements

    Abstract A waste treatment unit has been designed to recover water and various components from an aluminum can manufacturing process. Due to the scarcity of water in the Middle East and its inherent cost, water recovery is both necessary and cost effective. The manufacturing process generates: 1) an 11,356 L/hr (50 gpm) aqueous stream contaminated with hydrofluoric acid, dissolved aluminum, and ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you