reverse osmosis plant Articles

  • Reverse Osmosis Element Design

    Introduction  TORAY REVERSE OSMOSIS MEMBRANE ELEMENTS are functional membrane elements with excellent quality and high performance developed with the polymer engineering expertise Toray has gained over the years. Toray Reverse Osmosis Membrane Elements are high rejection and high flux RO elements that have been meeting the high level requirements of our customers in many applications: ...


    By Toray Membrane Europe

  • Innovative seawater intake for reverse osmosis desalination plants

    Seawater desalination plants typically consist of four major unit operations: seawater intake, pretreatment, Reverse Osmosis (RO) stage, and posttreatment and brine discharge. The best way is to go through vertical beach wells, but the increase of the production capacity of the plants built in recent years makes open intake the only solution. These open ocean intakes draw seawater through the ...


    By Inderscience Publishers

  • Reverse osmosis system to reclaim wastewater

    The Facility Pragati Power Corporation Limited, formerly Delhi Vidyut Board (DVB), was formed by the Government of National Capital Territory (NCT) of Delhi in 1997 for the purpose of generation and distribution of power to the entire area of NCT of Delhi. To bridge the gap between demand and supply and to have reliable power supply to the capital city of Delhi, a 330 MW combined cycle Gas ...

  • Experiences with the seawater reverse osmosis plant at the Kudankulam nuclear power plant

    The Seawater Reverse Osmosis Plant (SWROP) of the Kudankulam nuclear power plant is located at Anuvijay township, Chettikulam, Tirunelveli District, Tamil Nadu. The objective is to produce 2400 M³ of potable water per day. The plant consists of four streams, each having a capacity of 25 M³/h. Each stream has nine pressure tubes in parallel and each pressure tube has six polyamide spiral-wound ...


    By Inderscience Publishers

  • Reverse Osmosis Technology - Kuriverter Rc.

    Summary Applications using Reverse Osmosis membrane technologies are everywhere in our lives – from tiny under counter units polishing our drinking water through industrial units preparing water for processes or purifying effluents for reuse and massive seawater desalination plants producing thousands of m³ of drinking and irrigation water every day. The membranes used in this ...


    By Kurita

  • Reverse osmosis water recycling plants in Chennai & Gujarat, India

    GEA designed and built eight (8) drinking water RO plants for domestic use in Chennai and Gujarat, which have been experiencing serious drought conditions for the past 3 years. These residential private plants range from 2,000 to 15,000 GPD, typically averaging about 12,500 GPD. Source water is marginal or unsuitable ground or river water. Most systems have had a two-pass design to achieve ...


    By GEA ENGINEERING

  • Experiences with the conventional pretreatment system in the seawater reverse osmosis plant at Kalpakkam

    A 1800 m³/day Seawater Reverse Osmosis (SWRO) plant was commissioned in October 2002 at Kalpakkam, India, as part of the Nuclear Desalination Demonstration Project (NDDP). The conventional pretreatment scheme was adopted consisting of a lamella clarifier, pressurised sand filter, activated carbon filter and cartridge filter. The dosing of pretreatment chemicals, ferrous sulphate and ...


    By Inderscience Publishers

  • Repowering and Modification of Grid Connected Reverse Osmosis Desalination Plants

    Currently, there is a strong demand for efficient seawater desalination plants, which can meet the tougher environment regulation and energy saving requirements. From this standpoint the present work was undertaken to include the proposed schemes for repowering and modification of Reverse Osmosis (RO) desalination plants. The model of Modified Desalination Plant (MDP) during sunny periods may be ...


  • Assessment of an ultrafiltration pre-treatment system for a seawater reverse osmosis plant

    The seawater reverse osmosis system requires extensive pre-treatment in order to ensure reliable performance. The conventional pre-treatment system involves dosing of chemicals, which requires frequent monitoring of raw water quality, and also involves adjusting the dosage. Besides being cumbersome, there is a lot of time lag involved in carrying out these measures. This calls for pre-treatment ...


    By Inderscience Publishers

  • Optimizing scale inhibition costs in reverse osmosis desalination plants

    Over the last few decades, advancements in technology and engineering design have allowed for the construction of reverse osmosis (RO) plants with increased production capacities that could operate at reasonable energy costs. Yet the portion of the operating cost related to consumable scale inhibition chemicals has not changed dramatically due to the disregard by the water treatment community for ...

  • Fouling and cleaning of seawater reverse osmosis membranes in Kalpakkam nuclear desalination plant

    A seawater reverse osmosis plant of 1800 m³/day capacity is part of the 6300 ³/day capacity nuclear desalination demonstration project at Kalpakkam. The plant was commissioned in October 2002 and is in continuous operation. This paper deals with types of foulants, membrane cleaning procedures and the improvement in the reverse osmosis system after cleaning. This paper also describes the analysis ...


    By Inderscience Publishers

  • Evaluating impact of fouling on reverse osmosis membranes performance

    Abstract Membrane fouling is commonly defined as an undesirable formation of deposits on mem- brane surfaces and it is considered a major problem in most brackish, seawater, and waste water reclamation applications. Depending on nature of the scale and foulant, fouling pro- cesses will lead to decreased membrane fluxes, increased pressures needs, and/or increased permeate conductivity. ...

  • Reverse Osmosis Technology – KURIVERTER RC - Case Study

    Summary Applications using Reverse Osmosis membrane technologies are everywhere in our lives – from tiny under counter units polishing our drinking water through industrial units preparing water for processes or purifying effluents for reuse and massive seawater desalination plants producing thousands of m³ of drinking and irrigation water every day. The membranes used in this ...


    By Kurita

  • Ultrafiltration and Reverse Osmosis for Landfill Leachate Treatment

    Lanchester Landfill serves Eastern Lancaster County and Western Chester County in PA for disposal of household and construction waste. The facility produces around 10,000 gals per day of leachate. The Problem The facility ran a single basin sequential batch reactor (SBR) and a filter press to dewater the solids for many years, but found that they first, could not sustain a ...


    By Dynatec Systems Inc.

  • Innovations in the inhibition of reverse osmosis membrane scaling and fouling

    Abstract: Scaling and fouling of membranes is an on-going performance issue for most plants. There are continual improvements in membrane technology and plant design which increase efficiency, water quality and utilise different raw water supplies to produce clean pure water. This presentation outlines innovations in laboratory services and speciality chemicals designed to inhibit membrane ...

  • Reverse osmosis system reclaims 86% wastewater in singapore

    The Problem Singapore, a small island-state with few natural resources, currently imports about half of the country’s potable water supply from neighboring Malaysia and efforts are being made by the Singapore government o reduce dependence on imports. The increased success of recycling and reuse of waste water in Singapore is a key strategy to Singapore’s increased self ...

  • The safe use of cationic flocculants with reverse osmosis membranes

    Abstract Flocculants are used in combination with coagulants to agglomerate suspended particles for removal by filtration. This technique is used extensively in all types of surface waters to reduce the silt density index (SDI) and minimise membrane fouling. Although organic cationic flocculants are particularly effective, their widespread use in membrane applications is limited ...

  • On the performance limitation of reverse osmosis water desalination systems

    The performance of Reverse Osmosis (RO) water desalination processes was investigated using a simulated brackish water plant based on spiral-wound membranes. A semi-rigorous mathematical model was employed in the simulation to calculate the water and salt fluxes at any point along the filtration channel. The effects of two key parameters, namely the transmembrane pressure and membrane surface ...


    By Inderscience Publishers

  • Influence of feed quality on seawater reverse osmosis performance

    The trouble-free operation of a Reverse Osmosis (RO) plant relies on the quality of the treated feed water, which highlights the need for optimisation of the pre-treatment steps. The quality of raw seawater varies with time in terms of suspended and colloidal load, along with the dissolved salt content. In a conventional pre-treatment scheme, consisting of clarification and particulate and micron ...


    By Inderscience Publishers

  • Energy cost for desalination evaporation versus reverse osmosis

    The selection of the appropriate desalination technology between evaporation and reverse osmosis is grounded on several factors, including investment cost, maintenance cost, degree of availability, heaviness of the duty, and the required purity of the desalinated water. The main factor is often the running cost of the plant, and specifically the cost of the consumed energy. This paper intends to ...


    By Inderscience Publishers

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you