sample grinding Articles

  • Hurricane HR Cyclones to Reduce Emissions from Wet Woodchips Grinding at Verdo Renewables Ltd. (8 000 m3 /hat 20ºC) – Case Study

    Foreword Advanced Cyclone Systems, S.A. (ACS) designed and supplied two Hurricane Cyclones, HC series, for Verdo Renewables Ltd. The company is a fully owned subsidiary of Verdo Holdings A/S which has its HQ in Randers, Denmark. It has two production plants in the UK: Andover in Hampshire and Grangemouth in Scotland. Each plant has an annual production capacity of 55 000 tonnes of wood ...

  • Sample Handling Strategies for Accurate Lead-In-Soil Measurements in the Field and Laboratory

    ABSTRACT The inhomogenous lead-in-soil matrix can present serious obstacles to accurate sample collection and handling. In typical lead-in-soil measurement, particle size related errors in sampling and sample handling often exceed all other sources of error. The magnitude of error can vary widely depending on the particulate nature of the lead contaminant and the effectiveness of control ...

  • Detection of atrazine, alachlor, cyanazine and metolachlor in corn

    MATRIX: Grain corn ANALYTES: Atrazine, Alachlor, Cyanazine, and Metolachlor RANGE OF DETECTION: Atrazine: 20-1000 ppb Alachlor: 20-1000 ppb Cyanazine: 20-600 ppb Metolachlor: 20-1000 ppb MATERIALS: RaPID Assay Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized ...


  • Optical Polishing

    A mid-western firm who manufactures a large amount of specialty eyeglass lens was having a problem removing lead from their wastewater stream. This stream was a combination of the grinding effluent waster and the wash stream containing cleaning compounds. The normal effluent stream had a pH of 11- 11.5. The sample was treated without pH adjustment with the addition of Floccin-HP. The dosage was ...


    By Integrated Engineers Inc.

  • Detection of carbaryl in soil

    MATRIX: Soil ANALYTE: Carbaryl RANGE OF DETECTION: 40 to 500 ppb MATERIALS: SDI Carbaryl RaPID AssayÒ kit and Sample Diluent. SDI RaPID PrepÔ Soil Collection Kit (optional). SDI RaPID PrepÔ Extraction Kit: Type II (extraction solution, optional) Reagents: Methanol (pesticide grade), distilled or ...


  • Precellys application focus forensic - case study

    Forensic laboratories working with hard samples such as hair [1, 2J, bone [3], teeth, skin, etc. experience difficulties with DNA extraction due to the high energy needed to grind these tissues. Moreover, biological evidence is available in small quantities and the current techniques used do not provide high quality results. The Precellys homogenizers provides high speed sample disruption based ...

  • Enclosure for small laboratory equipment case study

    Process Details Large cryogenic mill designed for cryogenic grinding and pulverising tough and temperature sensitive samples immersed in liquid nitrogen. Supply Stainless steel desktop acoustic enclosure 760mm wide x 720mm deep x 710mm high Product selection Enclosure needed to be lockable, able to collect ...


    By Wakefield Acoustics Ltd

  • Cadmium and lead removal from municipal landfill leachate using carbon adsorbent made from oil palm shell

    This paper focused on adsorption process for metals removal from landfill leachate using oil palm shell as adsorbent. Raw shells were grinded to sizes of about 2 mm, followed by heating in at 420°C for a period of 4 hours. Batch test indicated a removal of more than 60% Cd and Pb from leachate samples. The removal process agrees with the Freundlich isotherm model. Column test for continuous flow ...


    By Inderscience Publishers

  • Detection of captan in soil

    MATRIX: Soil ANALYTE: Captan RANGE OF DETECTION: 8 to 300 ppm MATERIALS: Captan RaPID Assay, Kit and Sample Diluent. Reagents: acetone (pesticide grade) Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) with plastic lined screw caps, filtration apparatus (funnel and ...


  • Detection of 2,4-D in soil

    MATRIX: Soil ANALYTES: 2,4-D RANGE OF DETECTION: 150 ppb to 7.5 ppm MATERIALS: 2,4-D RaPID AssayÒ Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized water, glacial acetic acid. Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) ...


  • Detection of carbofuran in soil

    MATRIX: Soil ANALYTE: Carbofuran RANGE OF DETECTION: 10 to 500 ppb MATERIALS: Carbofuran RaPID AssayÒ kit and Sample Diluent. Reagents: methanol (pesticide grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles (polypropylene or high density polyethylene, 50 or 60 mL) with ...


  • Comparing Field Portable X-Ray Fluorescence (XRF) To Laboratory Analysis Of Heavy Metals In Soil

    ABSTRACT Field portable x-ray fluorescence (XRF) continues to gain acceptance as a complement to traditional laboratory testing of metal contaminated soil. The quality of data produced by field XRF varies with site conditions, soil composition, and sample preparation. Quality assurance protocols for the field method usually require that a number of field samples be split and sent to a ...

  • Detection of carbendazim in soil

    MATRIX: Soil ANALYTE: Carbendazim, a metabolite of benomyl RANGE OF DETECTION: 37.5 to 750 ppb MATERIALS: Benomyl/Carbendazim RaPID Assay kit and Sample Diluent Reagents: methanol (pesticide grade), sodium hydroxide (ACS grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles ...


  • Detection of atrazine, alachlor, cyanazine and metolachlor in soil

    MATRIX: Soil ANALYTES: Atrazine, Alachlor, Cyanazine, and Metolachlor RANGE OF DETECTION: Atrazine: 15-750 ppb Alachlor: 15-750 ppb Cyanazine: 15-450 ppb Metolachlor: 15-750 ppb MATERIALS: RaPID Assay Kit and Sample Diluent Reagents: methanol (pesticide grade), distilled or deionized water. ...


  • Beginners Guide to Spectroscopy - Transmission

    This is the first part of our introduction to Spectroscopy, more can be found on our blog (http://specac.blogspot.co.uk). Introduction Transmission spectroscopy is the oldest and simplest technique for analysing samples in infrared. This ...


    By Specac Limited

  • Detection of pentachlorophenol in soil

    MATRIX: Soil ANALYTES: Pentachlorophenol (PCP) RANGE OF DETECTION: 100 ppb to 10 ppm MATERIALS: Pentachlorophenol RaPID AssayÒ kit and Sample Diluent Reagents: methanol (reagent grade), sodium hydroxide (ACS grade), distilled or deionized water. Equipment: reciprocating shaker, plastic bottles (polypropylene or ...


  • Myco3 fumonisin test kit USDA GIPSA certified part # 7000130

    The following data is for the verification of the performance of the Myco4 Fumonisin Test Kit for the quantitative detection of fumonisins B1, B2, and B3 in whole corn, corn meal and corn germ. The Myco4 Fumonisin test kit can quickly and accurately detect the harmful mycotoxin Fumonisin in grains and feed. This mold causes Fusarium Ear Rot in corn which is the most common corn disease in the ...


  • Myco3 DON test kit USDA GIPSA certified part # 7000135

    The following data is for the verification of the performance of the Myco4™ DON Test Kit for the quantitative detection of deoxynivalenol (vomitoxin) in barley, malted barley, oats, corn and wheat. The Myco4 DON test kit can quickly and accurately detect the harmful mycotoxin DON (deoxynivalenol) in grains and feed. Due to the health concerns associated with DON, the U.S. has set advisory ...


  • Drum & Tote Washing Wastewater Treatment

    55 Gallon Drum 275 Gallon Tote Washing Wastewater Test Floccin™ 909 Treatment 100% Wastewater Reuse This facility receives 55-gallon drums (plastic) and 275 gallon totes (plastic and SS) from several different ...


    By Integrated Engineers Inc.

  • Hurricane for PM Emission Reduction from Dryer off Gases on a Wood Pellet Production Line 8074 m3/h @ 110 ◦C - Case Study

    FOREWORD Advanced Cyclone Systems, S. A. (ACS) designed a settling chamber, followed by a Hurricane system with the double purpose of dust recovery and Particulate Matter (PM) emission reduction, from a sawdust rotary dryer in an industrial wood pellets production plant with 2 ton/h capacity (VIMASOL). High quality pellets are manufactured from sawdust coming from nearby ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you