Modern wastewater utilities need to be able to measure and quantify the amount of methane from their treatment facilities in order to understand the potential energy that can be produced and the amount of methane being lost. This paper describes the application of a novel sampling bailer designed for the collection of wastewater samples that minimises methane losses. Samples collected during ...
These studies are the second part of a two year project that examines decontaminating groundwater sampling devices. In the first year, the efficiency of various decontamination protocols was tested using small test pieces of materials that are commonly used in groundwater sampling devices. Those tests showed that a hot detergent wash and rinse followed by hot air drying (105°C) was the most ...
What Is It? The HydraSleeve sampler is designed to collect representative water samples from monitoring wells without purging. The disposable sampler collects a discreet sample from only the 'fresh formation' water in the screened interval of the well. It is fast, inexpensive, simple to use, generates no purge water and collects a sample suitable for all analytical parameters. Why It Works The ...
There is currently a need for a simple, accurate and reproducible method that quantifies the amount of dissolved methane in wastewater in order to realize the potential methane that can be recovered and account for any emissions. This paper presents such a method, using gas chromatography with flame ionization detection fitted with a GS-Gas PRO column coupled with a headspace auto sampler. A ...
Any tank can leak. Most leaks can be cleaned up and responsible operators need equipment that does what’s needed. With an ATEX Zone 0 certified interface meter site operators can successfully achieve LNAP and DNAPL detection when monitoring petrochemical sites, tank farms, petrol station forecourts, landfills or remediation sites. If site technicians detect leaked product with an interface ...
Concentrations of total lead as high as 1,600 g/L were detected in gasoline-contaminated and uncontaminated groundwater at three gasoline-release sites in South Carolina. Total lead concentrations were highest in turbid groundwater samples from gasoline-contaminated and uncontaminated wells, whereas lower turbidity groundwater samples (collected using low-flow methods) had lower total lead ...
MWHS Americas, Inc. (MWH) was contracted by Dolver Company, Inc. to perform a Point Source Bailer Demonstration at Mather Air Force Base (Mather). This demonstration was initiated to evaluate no-purge technology and indicate the feasibility of using the HydraSleeve no-purge samplers as an alternative groundwater sampling method. On June 18, 2002, eight HydraSleeve point source bailers were ...
This site recently completed its 33rd quarter of groundwater monitoring with the Snap Sampler. To compare variability of the Snap Sampler with traditional volume purge methods, contaminant concentration changes over 9 monitoring periods were compared. Quarter-to-quarter changes in contaminant concentrations were tabulated and quarter-to-quarter relative percent change was compared. There were 81 ...
Nuclear licensed site use of low-flow groundwater sampling shows: Reduced time, reduced quantity of purge water – both thus reducing cost - and reduced risk of operator contact especially with potentially radioactive-contaminated purge water thanks to a self-contained enclosed system. One of the biggest headaches on site is the purge water and the expense of getting rid of it – after ...
This article describes a groundwater monitoring procedure that does not require decontamination of pumping equipment, eliminates the chance of cross contamination between wells, and uses a surface pump. Two surface pumps are described, one for water level depths less than 25 feet and one for water level depths greater than 25 feet. Install Dedicated Pumping Tubes A dedicated pumping tube ...
Selected ground water sampling and field-filtration methods were evaluated to determine their effects on field parameters and trace metal concentrations in samples collected under several types of field conditions. The study focused on conditions where traditional approaches may produce turbid samples, which often leads to filtration of suspended particles from the sample before laboratory ...
Untitled Document Abstract The Waterra Inertial Pump has been available for use in narrow diameter monitoring wells for several years. This device offers many advantages over other types of sampling equipment. Since this pump operates via a principle not used by any other type of device and is commonly constructed of materials not widely used in field sampling, some ...
Untitled Document ABSTRACT Concentrations of groundwater contaminants in samples that differ from concentrations in the aquifer can lead to incorrect conclusions about the extent and severity of contamination and the effectiveness of remedial measures. Sample collection and storage techniques affect measured concentrations in samples, particularly of organic compounds that ...
Untitled Document ABSTRACT Concentrations of groundwater contaminants in samples that differ from concentrations in the aquifer can lead to incorrect conclusions about the extent and severity of contamination and the effectiveness of remedial measures. Sample collection and storage techniques affect measured concentrations in samples, particularly of organic compounds that ...
Significant timesavings, improved sample process integrity, quality assurance and minimal quantities of potentially contaminated purge water to manage - are attractive as the focus on groundwater quality sharpens and economics demand best cost-benefit based methods Water has become a vitally important resource. Maintaining its quality and quantity and avoiding pollution are set to be watched ...
Untitled Document Background The Regional Superfund Ground Water Forum is a group of ground-water scientists, representing EPA's Regional Superfund Offices, organized to exchange information related to ground-water remediation at Superfund sites. One of the major concerns of the Forum is the sampling of ground water to support site assessment and remedial performance ...