sewer level sensor Articles

  • Sewer Level Monitoring - Photos

    Sewer Level Monitoring - Photos Photos in this article present the complexity and versatility of sewer level monitoring. When examining the photos, pay special attention to the stand-alone autonomous characteristics of each installation. In lack of any cabling from the outside, whether data cables or power cables, the solution is fed from its own battery power supply. Data is tranmitted ...

  • Case Study - Sewer Sensors

    Sewer Sensors Sewer sensors are offered by Solid Applied Technologies for remote level monitoring. The sesnors are ultrasonic, non-contact with no moving parts. The system is equipped with an external battery pack and can operate at a low-power-mode for long term life. The sensors are equipped with embedded GSM cellular modem and act as M2M terminals, transmitting data ...

  • Sewer Level Monitoring System - a case study

    Background - The business of sewage level monitoring in sewers is accelerating across many countries. Strict regulations, the need to avoid environmental disasters, violation fines, early warnings and planning needs are just some of the forces shaping this growing trend.   Challenges Quantifying sewage flow and level is one of the most ...

  • Open Channel Flow - The use of Level sensors for open channel flow measurement

    Open Channel Flow - The use of Level sensors for open channel flow measurement Level sensors from SolidAT are implemented in Open Channel Flow applications. In these types of applications, the level sensor is installed above a special water flow structure and accurately measures level of flowing water or wastewater. The sensor then calculates flow through the structure ...

  • Wastewater Level Measurement Techniques

    Level monitoring and control is a fundamental requirement in any wastewater treatment process. You will find level instrumentation installed at even the simplest treatment plants for pump control, chemical storage tanks and process level controls or alarms. Operators have only limited or emergency control over treatment plant influent, so level controls and instrumentation play an important role ...


    By Greyline Instruments Inc.

  • LIT25 level indicating transmitter controls swimming pool level

    The Town of Okotoks, Alberta I never gave it much thought, but what happens to the displaced water when a hundred people jump into a large public swimming pool? It goes into a surge tank - of course. This Greyline LIT25 Level Indicating Transmitter with ultrasonic sensor is installed in the basement of the Okotoks Recreation Centre in Alberta, Canada. The LIT's 4-20mA output is connected to a ...


    By Greyline Instruments Inc.

  • Environmental Sensors in Waste Management

    Issue: As part of an increasing sentiment among European consumers that environmental protection is important, concern about the impact of landfill is growing. Sensor technology makes it possible to measure and control inputs to landfill sites and pollutants arising from them. However, the exploitation - or uptake - of such technology has been lower than expected in the waste management sector. ...


  • Quantifying Sub-Surface Discharges from Individual Sewer Defects

    ABSTRACTThe California Regional Water Quality Control Board, Santa Ana Region (RWQCB) required wastewater collection agencies in Orange County to report discharges from “pipe breaks, leaking sewer pipes and joints, and other subsurface discharges of wastewater.” The Orange County Sanitation District (OCSD), in conjunction with a research team from University of California, Irvine (UCI), developed ...

  • Estimating inflow to a combined sewer overflow structure with storage tank in real time: evaluation of different approaches

    The performance assessment of storage tanks and combined sewer overflow (CSO) structures in sewer systems requires knowledge of the total inflow from the catchment during rainfall events. Many structures are, however, only equipped with sensors to measure water level and/or outflows. Based on the geometry of the tank, expressed as a level-storage relationship, inflow can be calculated from these ...


    By IWA Publishing

  • A sewer process model as planning and management tool – hydrogen sulfide simulation at catchment scale

    The collection system of a major city at the Persian Gulf was simulated for bulk water hydrogen sulfide and the release of sewer gas to the urban atmosphere. Geometry data on 870 km of sanitary sewer and data on dry weather flow entering all nodes in the catchment was exported from a Mike Urban database and imported to the sewer process model WATS. The process model then routed sewage and sewer ...


    By IWA Publishing

  • A method for on-line measurement of wastewater organic substrate oxidation level during aerobic heterotrophic respiration

    A method for on-line measurement of the organic carbon oxidation level (OXC) during aerobic heterotrophic respiration in domestic wastewater was developed and tested. The method is based on batch incubation of sewer wastewater in an intermittently aerated respirometric reactor. Between aeration cycles, measured pH, dissolved oxygen (DO) and dissolved carbon dioxide (CO2) were used to ...


    By IWA Publishing

  • Preventing waste water overspill in sewage pools case study

    Solid's SmartScan 50L provides an ultrasonic solution for effective sewer management in various locations. The waste water department of Jerusalem municipality in Israel is responsible for managing the city's complex sewer system. The system incorporates several sewage pools distributed in various locations, some of them in hard to reach locations. The problems The city of ...

  • Use of In-Line Inaflatable Dams for CSO Control

    ABSTRACTThe Detroit Water and Sewerage Department (DWSD) recently installed thirteen (13) in-line insystem storage devices (ISDs) in large combined sewers in Dearborn, Detroit, Hamtramck and Highland Park, Michigan. The ISDs are designed to store combined sewage in the sewers during wet weather, especially during smaller storms that do not utilize the full transport capacity of the sewers. The ...

  • Analytical Technology Helps Britannia Food Ingredients Ensure Safe Wastewater Disposal

    Britannia Food Ingredients Ltd. is a speciality fats company for the chocolate, confectionery, biscuit and snack food industries. The company are specialists in providing the demanding fat formulations found within chocolate, ice cream, bakery and snack food products. Located at Goole, East Riding of Yorkshire, England, the business was formed in 1996 and produces a range of oils and fats ...

  • Turbidity Measurements in Drinking Water, Effluent Discharges and Coagulant Controlling

    This month at Partech Water Instruments we’re talking about our turbidity sensors—fantastic to use as an environmental indicator. So how can they be used? We’re here to tell you about turbidity sensors being utilised for drinking water, effluent discharges and coagulant controlling. Turbidity Sensors and Drinking Water Turbidity sensors ...


    By Partech (Electronics) Ltd.

  • HawkEye CSO Discharge Alarm System

    Hawkeye is a two-channel GSM telemetry recorder and a joint venture between Hydro-Logic and IETG of Leeds. Hydro-Logic provide the key electronic and firmware technology basing it on our successful Hawk range of outstations. It was the first fully integrated measurement and telemetry system specifically designed to monitor the performance of Combined Sewer Overflows (CSO). All electronics ...

  • GaugerGSM - product highlights

    GaugerGSM is a remote level monitoring sensor, compact, cost-effective with unique firmware for detecting allerting events. GaugerGSM is based on an ultrasonic level meter integrated with cellular communication capabilities.    Novel integration of ultrasonic level sensor and GSM cellular modem ...

  • ‘Smart’ flood alleviation system protects Portsmouth

    In late 2014, Southern Water completed a major project to reduce the risk of sewer flooding in parts of Portsmouth and Southsea. Substantial works were undertaken to divert runoff and tidal ingress, and a ‘smart’ hydrometeorological monitoring system was installed to enable prompt diversion of excess water during periods of high rainfall. Sewer level monitoring is undertaken in ...

  • Evaporator Limits Boron to 5 PPM at award-winning chemical plant

    Problem: The biggest challenge confronting Rohm & Haas Corp. in building a wastewater plant for its chemical facility in Elma, Wash., was meeting Washington State Dept. of Ecology limitations on boron of 5 ppm. The Elma plant manufactures sodium borohydride, a versatile chemical used in a variety of applications ranging from the generation of sodium hydrosulfite for reductive bleaching of ...


    By Oil Skimmers, Inc.

  • How to Save with Cooling Tower Credits

    Cooling towers dissipate heat from recirculating water used to cool chillers, air conditioners, or other process equipment to the ambient air. Heat is rejected to the environment from cooling towers through the process of evaporation. Therefore, by design, cooling towers use significant amounts of water. The thermal efficiency and longevity of the cooling tower and equipment depend on the proper ...


    By WaterSignal

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you