soil analysis immunoassay Articles

  • RaPID Assay Cyclodienes in soil application

    Intended Use For detection of cyclodiene insecticides (as dieldrin) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00256EA) Procedural Notes and Precautions Prepare soil ...


  • RaPID Assay PAH in soil application

    Intended Use For detection of Polynuclear Aromatic Hydrocarbons (PAHs) (as phenanthrene) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00160EA/A00160EB) Procedural Notes and Precautions ...


  • RaPID Assay PCB in soil application

    Intended Use For detection of Polychlorinated Biphenyls (PCB’s) (as Aroclor 1254) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00137EA/A00137EB) Procedural Notes and Precautions ...


  • RaPID Assay carcinogenic PAHs in soil application

    Intended Use For detection of Carcinogenic PAHs (as benzo(a)pyrene) in soil. For testing in other matrices, please contact our technical support department at 1-800-544-8881. Materials Required but Not Provided SDI Sample Extraction Kit (Part Number: A00204EA/A00204EB) Procedural Notes and Precautions Prepare ...


  • Semi-quantitative analysis using the ensys methods with the RPA-I

    MATERIALS: SDI EnSys Soil or Wipe Test Systems , RPA-I Analyzer (Item #A00003) PROCEDURE Follow the appropriate EnSys Test System User’s Guide for sample preparation and analysis. Except at Phase 3: The Immunoassay - Color Development, add 400 mL of Stop Solution instead of 200 mL by setting the Eppendorf repeater on 4 instead of 2. ...


  • Single field mobilization completes site investigation and removal actions

    The Kentucky Research Consortium for Energy and the Environment (KRCEE) worked with the U.S. Department of Energy (DOE) last summer to introduce new approaches and technologies to the site cleanup program operating at the Paducah Gaseous Diffusion Plant (PGDP) in western Kentucky. A Triad demonstration was conducted at PGDP's Area of Concern (AOC) 492 that integrated several real-time ...

  • Lower costs, fewer delays - a highway expansion project applies XRF technology to obtain cost-effective remediation.

    X-ray fluorescence (XRF) spectrometry is a non-destructive, analytical method used primarily to detect the metal composition in soil/solids samples. Portable XRF instruments can provide rapid, accurate analysis of heavy metal levels in soil on new construction or redevelopment sites. In response to the growing need for field analysis of metals, many of these units have been adapted for use in the ...

  • Detection of polychlorinated biphenyls (PCBS) in concrete

    MATRIX: Concrete ANALYTES: Polychlorinated biphenyls (PCBs) RANGE OF DETECTION: 500 ppb to 10 ppm MATERIALS: SDI PCB RaPID Assay® Kit. SDI RaPID Prep® PCB Sample Extraction Kit. SDI RaPID Prep Soil Collection Kit. Reagents: table salt (sodium chloride) or salt packets used by restaurants (e.g. Dixie ...


  • Vapor-Phase Biofilters Show Promise for Treating High VOC Emissions

    Evaluating the Feasibility of Natural AttenuationUsing natural attenuation to remediate organic compounds in groundwater has gained popularity. In some cases, this process can reduce contaminant levels to below risk-based corrective action criteria or regulatory standards without implementing additional remedial action alternatives. However, it is often difficult to prove that natural ...


  • Vapor-Phase Biofilters Show Promise for Treating High VOC Emissions.

    Evaluating the Feasibility of Natural AttenuationUsing natural attenuation to remediate organic compounds in groundwater has gained popularity. In some cases, this process can reduce contaminant levels to below risk-based corrective action criteria or regulatory standards without implementing additional remedial action alternatives. However, it is often difficult to prove that natural ...


  • Performance-Based Measurement Systems

    Many of the Environmental Protection Agency's (EPA's) methods used to monitor air, water and soil for environmental contaminants prescribe step-by-step details on how the chemical analysis must be conducted and prohibit any deviations or variations. The EPA has recognized that monitoring equipment and technology have improved tremendously over the last few years; that environmental media do not ...


    By WSP | Parsons Brinckerhoff

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you