soil tph test Articles

  • On-Site TPH in Soil Measurements

    On-site analysis of total petroleum hydrocarbon (TPH) concentration levels in soil are easily handled using the InfraCal TOG/TPH Analyzers manufactured by Wilks Enterprise, Inc.  The InfraCal TOG/TPH Analyzers are portable infrared (IR) analyzers that quickly determine TPH levels in less than 10-15 minutes, including the extraction.  Concentrations as low as 10 ppm to well over 10,000 - ...


    By Spectro Scientific

  • A Simplified Procedure for the Determination of TPH’s in Waters and Soils Using the HC-404 System

    The determination of Total Petroleum Hydrocarbons (TPH), greases, and lubricant residues are important environmental and industrial tests. Fuel and lube oils can be determined in water and soils to track spills and storage tank leaks, while many military and industrial situations require certain components (gas regulators, space shuttle components, weaponry parts, etc.) to have a maximum limit of ...


    By Buck Scientific Inc

  • Can I extend the range of the TPH in Soil kit by dilution?

    The pocket colorimeter kit by Hach offers an immunoassay method to measure TPH (Total Petroleum Hydrocarbons) in soil samples – a useful indicator of petrol pollution or contamination in soil. For areas of heavy contamination the range of the test can be extended by dilution during the soil extraction step. ...


    By Camlab Limited

  • Rapid Analysis of Petroleum Hydrocarbons (TPH) in Soil and Water by Infrared Spectroscopy

    In 1988 the US EPA estimated that there were 3 to 5 million underground chemical storage tanks (UST’s) in the United States, of which up to 1% would develop leaks every year. In response to growing concerns about the quality and future availability of safe drinking water, federal and state programs have begun to systematically replace virtually all UST’s installed before 1986 either with above ...


    By Buck Scientific Inc

  • Bioremedation and TPH analysis at Lumwana Copper Mine in Zambia

    MINING SITE: Equinox Minerals operates the biggest copper mine in Africa located at Lumwana in Northwest province Zambia.  Open pit mining methods are used to access the ore which is hauled to the process plant where it is crushed and processed into final concentrate. The mine operates a large fleet of equipment, including 27 EH4500 dump trucks, 5 shovels, 4 excavators ...


    By Sitelab Corporation

  • Case study - TPH Oil & Grease applications

    These case studies illustrate the performance generated from customers who have used Sitelab’s UVF-3100 analyzer for testing total petroleum hydrocarbons in the C10 to C50 range. Sitelab’s TPH-Oil calibration kit is designed to correlate well to laboratory “Oil and Grease” test methods. This includes EPA Methods 1664 and 9071B by Gravimetric, EPA Method 418.1 by Infrared ...


    By Sitelab Corporation

  • On-Site TPH in Soil Measurements in less than 15 Minutes with Portable IR Analyzers

    On-site analysis of total petroleum hydrocarbon (TPH) concentration levels in soil are easily handled using the InfraCal TOG/TPH Analyzers manufactured by Wilks Enterprise, Inc.  The InfraCal TOG/TPH Analyzers are portable infrared (IR) analyzers that quickly determine TPH levels in less than 10-15 minutes, including the extraction.  Concentrations as low as 10 ppm to well over 10,000 - ...


    By Spectro Scientific

  • Biodegradation of total petroleum hydrocarbon (TPH) in Jordanian petroleum sludge

    Bioremediation, or the use of micro-organisms to decontaminate soil or groundwater, is being increasingly seen as an effective, environment-friendly treatment for oil-contaminated sites. In this study, the results are presented concerning a laboratory screening of several natural bacterial consortia and laboratory tests to establish the performance in degradation of hydrocarbons contained in oily ...


    By Inderscience Publishers

  • Oil in frac water testing

    The amount of water used in and produced by hydraulic fracturing of shale gas wells is in the millions of gallons per well. Whether the water is going to be taken off site for disposal or reused for re-injection, the flowback or produced water needs pretreatment to remove any residual oil from the wa-ter. Waiting for remote laboratory results can take several days to a week. The InfraCal TOG/TPH ...


    By Spectro Scientific

  • Tyco earth tech - soil bioremediation

    Summary: In June 2006 EarthTech (a member of the Tyco group of companies) undertook the bioremedial clean-up treatment of hydrocarbon contaminated muddy gravel at one of their sites in Hungary. The muddy gravel was contaminated with TPH levels in excess of 300,000 mg/kg in parts and was a stern test for the feasibility of bioremediation within the region. The project was ...


  • New ASTM Test Method Offers Quick and Easy Oil and Grease Measurement for Water and Soil Samples

    Onsite Field Measurement of Oil and Grease A quick and easy field analysis method for determining oil and grease concentration levels is important for both offshore oil platforms and soil remediation sites.. Prior to the Montreal Protocol, infrared (IR) analysis using Freon as an extraction solvent was a widely used field and laboratory method. In 1999, the U.S. EPA promulgated Method 1664A ...


    By Spectro Scientific

  • CH#952 - Oil Contaminated Soil

    SITE OWNER: A National Overnight Express Package Company SITE SURVEY: Site and geological surveys revealed a contaminated area north of the facility and west of a diesel tank pit. The cause of the contamination was the result of two (2) underground storage tanks (UST™). One tank contained waste oil while the other contained new oil. Both tanks had ...


    By BIO-SYSTEMS International

  • Case study - EDRO in soil at wharf remediation site

    Sitelab Calibration Kit CAL-042 is used for EDRO analysis. The UVF-3100 detects hydrocarbons in the C10-C36 range. A Licensed Site Professional (LSP) used Sitelab to investigate a commercial waterfront property, contaminated with a plume of LNAPL resulting from fuel tanks which once stored heating oil, diesel and gasoline dating back to the 1950s. The site is in Massachusetts, where laboratories ...


    By Sitelab Corporation

  • Case study - Texas crude oil in soil sites

    Sunset Well Service, Inc. is an environmental contractor located in the Midland/Odessa area of Texas. They use their UVF-3100D analyzer to help excavate and remediate soils contaminated by produced water and crude oil. Laboratories in Texas test TPH using the TX 1005 GC-FID Method. This method is similar to U.S. EPA Method 8015M, but reports the GRO, DRO and ORO fractions separately. Soils from ...


    By Sitelab Corporation

  • Case study - Nigeria crude oil in soil site

    Safic Technologies, Ltd. - Port Harcourt A pilot study was conducted testing soil samples collected from a pipeline spill. Split samples were sent to Sitelab for EDRO analysis and results were the same. Samples were also sent to a Nigerian lab and a highly reputable lab in the United States for confirmation. After testing the samples a second time, the American lab got better results. ...


    By Sitelab Corporation

  • Bioremediation of hydrocarbon impacted soils - Marchbanks, Dundee

    Client: Dundee City Council Objective: Bioremediation of hydrocarbon contaminated soils to achieve compliance with the Waste Acceptance Criteria (WAC) for Mineral Oil (C10 – C40); with the intention of re-using the soils to Riverside Recycling Centre to be used as a capping layer. Challenge: Approximately 2,800 m3 of hydrocarbon ...


    By Soilutions Ltd

  • Case study - GRO in soil at gasoline UST site

    These case studies show the performance using Sitelab’s UVF-3100 analyzer testing gasoline range organic hydrocarbons.  This includes benzene, xylene, BTEX and other volatile petroleum compounds in the GRO or VPH C6 to C10 hydrocarbon range. When calibrated using Sitelab's GRO calibration kit (CAL-025), the UVF analyzer produces test results that correlate well to laboratory ...


    By Sitelab Corporation

  • Toxicity of fuel contaminated soil to antarctic moss and terrestrial algae

    Fuel pollution is a significant problem in Antarctica, especially in areas where human activities occur, such as at scientific research stations. Despite this, there is little information on the effects of petroleum hydrocarbons on Antarctic terrestrial biota. This paper demonstrates that the Antarctic mosses Bryum pseudotriquetrum, Schistidium antarctici, Ceratodon purpureus and the Antarctic ...


    By John Wiley & Sons, Ltd.

  • Case study: EPA region 9

    ISTR Overview Neighborhood: Industrial Heating Tubes: 14 Target Temp: 325 ˚C Heating Period: 130 Days Target: 0.9 mg/kg for Benzene Contaminant: TPH-d TPH-mo Benzene Naphthalene BaP Geology: ...

  • Case Study: Highland Elementary School

    Prior to constructing new classroom buildings on newly acquired property adjacent to Highland Elementary School, the California Department of Toxic Substance Control (DTSC) requires that soil testing be conducted as part of a 'Preliminary Endangerment Assessment' (PEA). Ellis is administering testing of soils near existing buildings (lead), and beneath the location of a former hydraulic elevator ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you