stack emissions analysis Articles

  • Analysis of Stack Emissions Using VOST Air Sampling Tubes and Capillary GC

    United States EPA SW-846, Method 0030, Volatile Organic Sampling Train (VOST), describes the sampling of emissions for volatile compounds from hazardous waste incinerator stacks. Supelco's VOST air sampling tubes are designed to fulfill the method requirements and provide low background levels.               ...


    By MilliporeSigma

  • The Portable FID for Stack Emissions: lightweight, compact, ergonomic, safe

    POLLUTION S.r.l. manufactures POLARIS FID analyser, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...

  • Air pollution control using laser analysis – Case Study

    An LDS 6 analyzer monitors HF emissions during the production of hydrofluoric acid in accordance with the German Technical Instructions on Air Quality Control (TA Luft) The customer Fine chemicals and inorganic basic chemicals have been developed and produced at the Seelze chemical site in northern Germany for more than 100 years. Such a basic chemical is ...

  • In-situ continuous emissions monitoring & regulatory compliance

    As environmental scrutiny has risen and regulation has tightened in recent years, the importance of having accurate information on the environmental performance of your power plant has increased. After all, if you want to manage something, you need to be able to measure it. The analogy is obvious; you wouldn't start a diet without first investing in a set of scales. So it is with Continuous ...

  • White Paper & Video on FTIR multigas analysis

    Gasmet Technologies has published a free White Paper and a video on the simultaneous measurement of multiple gases in a wide variety of applications using FTIR. Both the video and the White Paper can be found here at www.gasmet.com or by visiting the Quantitech stand 62/63 at AQE 2017. ...


    By Gasmet Technologies Oy

  • Free White Paper on FTIR Gas Analysis

    Gasmet has prepared a White Paper on the simultaneous measurement of multiple gases in a wide variety of applications using FTIR (Fourier Transform InfraRed) technology. With the ability to measure almost any gas, FTIR monitoring technology is employed in an enormous variety of applications including Continuous Emissions Monitoring, Stack ...


    By Gasmet Technologies Oy

  • Analysis of PCBs in emission samples: non ortho, mono-ortho and homolog totals by level of chlorination

    IntroductionPolychlorinated biphenyls (PCBs) are one of the most widespread persistent organic pollutants, identified in every component of the global ecosystem. A production of approximately 2 * 10 9 Kg technical PCB occurred form 1930 to the late 1970 1 and the total amount released into the environment is estimated in 370. 000 2 tonnes. Twelve of the possible 209 PCBs are non- and mono-ortho ...


    By Monitoring Systems GmbH

  • Characterisation for some emission sources in CMB calculation for Mae Moh area, Thailand

    Particulate samples of agricultural waste burning, straw burning, forest leaf burning, heavy duty truck emission, paved road dust, soil, agricultural soil, coal, electrostatic precipitator ash, and emission from stack power plant were collected from the Mae Moh area. Chemical compositions of sampling filters were analysed to determine the particulate matter source profiles. The analysis included ...


    By Inderscience Publishers

  • Carbon Fiber Emission Control Strategies

    Problem Carbon fiber (fibre) and graphite reinforced polymers are materials that have, and will continue to revolutionize the products we use everyday by making them stronger, lighter and more durable. However, the manufacturing process can have serious environmental ramifications and immediate danger to human health if careful consideration is not given to emission control at the ...

  • An analysis of extinction coefficients of particles and water moisture in the stack after flue gas desulfurization at a coal-fired power plant

    Two important factors that affect in-stack opacity—light extinction by emitted particles and that by water moisture after a flue gas desulfurization (FGD) unit—are investigated. The mass light extinction coefficients for particles and water moisture, kp and kw, respectively, were determined using the Lambert-Beer law of opacity with a nonlinear least-squares regression method. The ...

  • Tips for Refinery Gas Analysis

    Refinery gas analysis (RGA) is an important application in oil and gas which characterizes the gases produced during crude oil refining, including stack emission, flame and reformate streams. The challenge in RGA analysis is the reliable analysis of variable sources and compositions of gases produced via fluid catalytic cracking (FCC). The analysis must be quick and accurate to allow engineers to ...

  • Infrared differential absorption Lidar (DIAL) measurements of hydrocarbon emissions

    We report the application of an infrared (IR) differential absorption Lidar (DIAL) system (also capable of ultra violet measurements) built at the National Physical Laboratory (NPL), UK, to field measurements of total site emissions (controlled and fugitive) from petrochemical and landfill installations. The validation of the IR-DIAL was carried out via a series of controlled field experiments ...

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By ENVEA

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By ENVEA

  • Proposed boiler MACT sets aggressive emission limits

    On June 4, 2010, U.S. EPA proposed National Emission Standards for Hazardous Air Pollutants (NESHAP) for industrial, commercial, and institutional boilers and process heaters at both major and area sources of hazardous air pollutants (HAP) emissions.  EPA proposed separate rules for units at major sources of HAP emissions (greater than 10 tons per year [tpy] of any single HAP and/or greater ...


    By Trinity Consultants

  • Mercury Analysis

    Characteristics of Mercury What is Mercury? Mercury is a naturally occurring silver-colored metallic element noted for its occurrence as a liquid at room temperature and toxic to living organisms. This silvery, opaque liquid metal is very dense, yet has a high surface tension that causes it to form tiny perfect spheres in the pores of the rocks it is found in. It is ...


    By HORIBA Europe GmbH

  • A cure for Environmental Emissions case study

    Disposing of nearly 1 million pounds of medical waste a month is no easy task. The wet electrostatic precipitator, installed at Rochester, MN-based Mayo Clinic, seems to be just what the doctor ordered. While the medical waste incinerator at Mayo Clinic in Rochester, MN, consistently met state and federal emission requirements, facility leadership recognized that installing a wet electrostatic ...


    By Bionomic Industries Inc.

  • Analyzing Stack Gas Semivolatiles, Using Supelpak-2 Adsorbents and Capillary GC (Modified Method 5, US EPA SW-846)

    The demanding detection limits required for air sampling by Modified Method 5 (US EPA SW-846, Method 0010) necessitates extensive cleaning and meticulous handling of the adsorbent cartridge/trap during sampling and analysis. Supelpak-2 adsorbent is cleaned in accordance with and meets the purity criteria of EPA SW-846, Method 0010, for testing semivolatile emissions from incinerator stationary ...


    By MilliporeSigma

  • Magnetic Fuel Treatment Bottom Line Analysis

    BOTTOM LINE ANALYSIS This cost savings analysis was prepared in cooperation with Master Chief Hill of the US Coast Guard Maintenance & Logistics Command using data from the 82’ Cutter Pt. Chico, and 110’ Cutters Anacapa and Long Island over a period of two years when ALGAE-X® performance was monitored and evaluated. Installation of ALGAE-X® units in Diesel Engine applications results in ...


    By AXI International

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you