stack gas analyzer Articles

  • Stack gas VOC monitoring

    POLLUTION S.r.l. manufactures POLARIS FID analyzer, a cutting-edge technology for the measurement of total hydrocarbons in ambient air and stack emission monitoring in accordance with EN 13526 and EN 12619. This analyser is based on Flame Ionization Detection (FID), a reference method technique to measure total hydrocarbons (THC, VOC, TOC). Polaris FID is a very handy instrument because it allows ...

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics

  • The Flexibility & Versatility of a Portable Emissions Analyzer

    Issue Fixed CEMS (Continuous Emissions Monitors) Measure at One Location CEMS are fixed units that typically only measure from one sample location which is usually on a main centralized stack. This main stack is often fed by several separate emissions sources throughout the plant such as boilers, heaters, engines, ovens, and furnaces. If the CEM ...

  • FTIR resolution requirements for industrial gas analyzers

    FTIR Spectroscopy is a widely used technique for gas analyses in industrial applications. It is a technique used in the semiconductor industry for measuring the purity of cleaning, etching, and epi-treatment gases used with various process tools, reactors, and abatement devices. Among chemical companies and R&D facilities, FTIR is applied to combustion thermodynamics and stack gas emissions; ...


    By CIC Photonics

  • Natural Gas Processing Case Study

    The Customer The Company is an exploration and production company that builds natural gas reserves through the acquisition and development of oil and gas assets across the U.S. They are one of the largest producers of natural gas in the Nation. The Process The Company uses multiple scrubbers to clean out the impurities of the natural gas that they ...

  • AMETEK PI wins stack gas/emissions analyzer category bronze medal award in control magazine reader choice awards

    Every single interaction between customer and supplier is an oppor-tunity for providing good solutions. After awhile, these positive mo-ments really begin to add up. Despite the huge effort and extreme consistency required, the best vendors almost re¬ exively deliver useful products and services, and con-tinually develop and release new improvements and innovations. Con-sequently, over ...


    By AMETEK Process Instruments

  • Free White Paper on FTIR Gas Analysis

    Gasmet has prepared a White Paper on the simultaneous measurement of multiple gases in a wide variety of applications using FTIR (Fourier Transform InfraRed) technology. With the ability to measure almost any gas, FTIR monitoring technology is employed in an enormous variety of applications including Continuous Emissions Monitoring, Stack ...


    By Gasmet Technologies Oy

  • Analyzing Stack Gas Semivolatiles, Using Supelpak-2 Adsorbents and Capillary GC (Modified Method 5, US EPA SW-846)

    The demanding detection limits required for air sampling by Modified Method 5 (US EPA SW-846, Method 0010) necessitates extensive cleaning and meticulous handling of the adsorbent cartridge/trap during sampling and analysis. Supelpak-2 adsorbent is cleaned in accordance with and meets the purity criteria of EPA SW-846, Method 0010, for testing semivolatile emissions from incinerator stationary ...


    By MilliporeSigma

  • The Flexibility & Versatility of a Portable Emissions Analyzer - Case study

    Issue Fixed CEMS (Continuous Emissions Monitors) Measure at One Location CEMS are fixed units that typically only measure from one sample location which is usually on a main centralized stack. This main stack is often fed by several separate emissions sources throughout the plant such as boilers, heaters, engines, ovens, and furnaces. If the CEM ...

  • FTIR Gas Analyzer Helps Pöyry in QAL2 and AST Compliance Measurements

    Several EU directives and national laws in the European countries set requirements for continuous monitoring of flue gas emissions. Pöyry helps industrial plants meet stringent environmental standards by offering emission measurement services like compliance measurements, for example. We spoke to measurement team manager Paula Juuti at Pöyry about her work with emissions ...


    By Gasmet Technologies Oy

  • Determination of TOC in stack through the innovative FID analyser easy to carry - Case Study

    PROBLEM: The industrial chimney's emissions of Volatile Organic Compounds (VOCs) are becoming issues of global importance and to have an accurate knowledge about how to test VOC turns into a strategic issue. VOC emissions are quantified and monitored according to standard EN 12619, using FID analyzer which uses hydrogen and other reference gases in ...

  • Heating value

    The CustomerThis Chemical Company is a leading supplier of performance polymers. Their products are used in a wide range of applications including adhesives, coatings, consumer and personal care products, sealants, lubricants, medical, packaging, automotive, paving, roofing and footwear products. The ProcessThe company uses flare stacks to dispose of the waste products ...

  • Testing the Performance of a DeNOx System Using a Portable Emissions Analyzer - Case study

    Using Portable Emissions Analyzers to Measure the Performance of a NOxReduction System in a Power Plant Boiler The majority of power plants utilize NOx reduction systems (eg. Ammonia Injection, SCR, etc.) in their power boilers to ensure that the NOx emissions levels comply with current regulations. The frequent evaluation of the ...

  • Developing Technologies to Detect Hydrogen Sulfide (H2S) Gas

    Abstract Hydrogen sulfi de (H2S) gas can cause nausea, headaches, unconsciousness, and death. Industries struggle to detect this deadly substance before it harms workers or communities. Safety system manufacturers have developed detectors that sense the H2S quickly and accurately. This paper illustrates, in general terms, considerations in effective placement of H2S detectors: ...

  • Global solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By ENVEA

  • Total solution: Gas and particulate analysis in Cement industry

    Cement plants are increasingly required to install continuous emission monitoring systems (CEMS). While these represent a significant financial outlay, a range of other factors also need to be considered when selecting a suitable CEMS. To the inexperienced, selecting a suitable CEM can mistakenly be considered as simply ensuring that the applicable national regulations (eg MACT in the USA, ...


    By ENVEA

  • Process & Emissions Optimization - Case study

    There are many locations that should be measured and monitored with a portable emissions analyzer to maximize product quality, combustion efficiency, safety, and emissions reduction in a cement plant including the following: Rotary Kiln gas outlet O2, CO, NOx, CO2, SO2, CxHy, temperature ...

  • Air pollution control using laser analysis – Case Study

    An LDS 6 analyzer monitors HF emissions during the production of hydrofluoric acid in accordance with the German Technical Instructions on Air Quality Control (TA Luft) The customer Fine chemicals and inorganic basic chemicals have been developed and produced at the Seelze chemical site in northern Germany for more than 100 years. Such a basic chemical is ...

  • Continuous measurement of Process oxygen for Claus sulfur recovery unit (sru) start-ups and shut-downs case study

    During start-up and shut-down, any time a sulfur recovery unit (SRU) transitions from ambient temperature through fuel gas warm up to the introduction of acid gas, measurement of 02 stoichiometry is critical. Historically, operators have manually taken samples using a portable electrochemical type Os analyzer. While giving more or less satisfactory results, the requirement for more stringent ...


    By AMETEK Process Instruments

  • Wastewater Treatment Plant Monitors Greenhouse Gas Emissions

    Globally, little attention is paid to gaseous emissions from wastewater treatment processes. This contrasts greatly with the regulatory monitoring that is applied to the quality of water emissions from such facilities. However, in Helsinki, Finland, a large municipal wastewater treatment facility continuously monitors its emissions of greenhouse gases (GHGs) to help in the city’s efforts to ...


    By Gasmet Technologies Oy

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you