stack monitoring Articles

  • Stacking up: flare Monitoring from LumaSense

    Lenny Shaver, LumaSense Technologies’ director of product management, explains the company’s IR and pyrometer technologies FLARING systems are common in many industries to burn gases before they enter the atmosphere. The safe operation of a flaring system requires the continuous monitoring of pilot flames and flared gases to ensure that vented gases are ignited. As ...


    By LumaSense Technologies, Inc.

  • Selection of Particulate Monitors

    The installation and operation of continuous particulate emission monitors in industrial processes has become well developed and common practice in industrial stacks and ducts over the past 30 years reflecting regulatory monitoring requirements. It supports requirements originating from LAPPC (Local Air Pollution Prevention and Control), IPPC (Integrated Pollution Prevention and Control), WID ...


    By ENVEA

  • The 10 Key Factors in Selecting a Stack Sampling Firm

    Summary: This document is a summary of the key factors that you should take into consideration when hiring a stack testing firm.This has been prepared in conjunction with the ASTM criteria for standard practice of testing companies.The ASTM criteria has been supplemented, based on 125 years of direct testing experience, which is the combined years of experience of the individuals that contributed ...

  • Continous Emission Monitoring (CEMs)

    Presented in Track B1: CEMs at EUEC 2011,January 31 Phoenix, Arizona   B1.1  | Particulate CEM for wet FGD plant William Averdieck |  Managing ...

  • Compliance to standards in continuous emissions monitoring case study

    Customer: Glass Manufacturer Application: Continuous Emissions Monitoring Service (CEMS) for Glass Manufacturing Background: A glass factory is required to ...


    By Ecotech Pty Ltd

  • NEO Monitors conquers the Quasi-impossible

    China is a world factory powered by its abundant coal resource. China is facing a huge environmental challenge brought together with the fossil-fired power plants. China has therefore been conducting technical retrofit to the engines of its economy, by introducing emission control facilities. Selective Catalytic Reduction (SCR) technology is one of the most widely applied emission control ...


    By NEO Monitors AS

  • Practical Implementation of EN-14181in Particulate Monitoring - Case Study

    Introduction This case study summarises the results of implementing particulate monitoring according to EN-14181 in a municipal incinerator operated by SUA in Teesside, UK, with a ProScatter M type particulate instrument (Model PCME QAL 181). It also provides a comparison of results for monitoring the same stack with an ElectroDynamic particulate instrument (Model PCME QAL 991). This case ...


    By ENVEA

  • FTIR gas monitor for diverse applications

    QUANTITECH, a leading supplier of environmental monitoring instrumentation, has recently supplied EURO Environmental Services in Ireland with a transportable Gasmet FTIR multiparameter gas analyser which EURO Environmental's Managing Director Geoff Fitzpatrick says, “is proving invaluable in many varied applications across a broad selection of industries.” With headquarters in Drogheda in Ireland ...


    By Quantitech Ltd

  • Choosing flow monitors for CEMS applications

    As a result of the 1990 Clean Air Act Amendments1, electric power plants must reduce their emissions of sulfur dioxide and nitrous oxides—the primary causes of acid rain. The U.S. Environmental Protection Agency (EPA), in its proposed rules2, designates the 111 Phase I fossil-fueled plants ^roughly 268 boiler units) that must have continuous emissions monitoring systems (CEMS) installed, ...


    By Sierra Instruments, Inc.

  • Utility Monitoring in a School Building

    Universal Input Data Loggers Offer Total Building Solution A customer needed a utility monitoring solution to accurately monitor utility usage in a school building, totalized by floor. They needed to present this data in an easy-to-understand dashboard for each wing and as an aggregate total for the entire building. The client also had electric sub-panels on each floor, but they are separated ...


    By CAS DataLoggers

  • Innovative emissions monitoring uptake soars

    Firms in the UK’s waste and power sectors are proactively seeking Best Available Techniques for emissions monitoring, according to Enviro Technology. Over recent months there has been a surge in demand for sophisticated equipment, such as monitors of total gaseous mercury. The air quality and emissions monitoring specialist believes that a combination of factors, such as the recast ...

  • Development and Implementation of an Alternative Emissions Monitoring Program for Carbon Monoxide Compliance for Fluidized Catalytic Cracking Unit CO Boilers

    This paper presents the results of an alternative emissions monitoring test program for the Fluidized Catalytic Cracking Unit (FCCU) CO boilers at major oil refinery. Alternative emissions monitoring systems can be used in lieu of other compliance monitoring techniques (e.g., periodic emissions testing, continuous emissions monitoring) to relate monitored operating conditions which might indicate ...

  • How does climate stack up against other worst-case scenarios?

    Climate isn’t the only catastrophe threatening the planet, but it may be the one most in need of attention and resources. The following is excerpted from Climate Shock (2015) by Gernot Wagner and Martin L. Weitzman. Published here with permission from Princeton ...


    By Ensia

  • Locus and Overhoff to Offer Real Time Tritium Monitoring and Compliance Software at Nuclear Facilities

    Locus Technologies (Locus), the industry leader in web-based environmental compliance and information management software, and Overhoff Technology Corporation, the world's leader in the design and manufacture of Tritium monitors and radiation monitoring systems, have partnered to offer a complete Tritium monitoring solution for the nuclear industry using Overhoff's Tritium instrumentation and ...


    By Technical Associates

  • LATEST TECHNOLOGY: Smartphone SVE BLOWER & OXIDIZER SYSTEMS with Remote Monitoring

    SOIL-THERM designs and builds SVE Blower and Oxidizer systems for environmental and remediation applications that are full of features and LOW in price. By integrating advanced PLC capabilities into these systems, SOIL-THERM offers our customers a whole new level of capabilities.  The SVE Blower system with or without oxidizer allows changes to flows, blower speeds, alarms, manual ...


    By Soil-Therm Equipment, Inc.

  • How to align an opacity monitor

    Correct optical alignment is essential for any opacity monitor. If the instrument is misaligned, its readings will be unstable. There may also be an offset, and this can be either positive or ...


    By AMETEK Land

  • An analysis of extinction coefficients of particles and water moisture in the stack after flue gas desulfurization at a coal-fired power plant

    Two important factors that affect in-stack opacity—light extinction by emitted particles and that by water moisture after a flue gas desulfurization (FGD) unit—are investigated. The mass light extinction coefficients for particles and water moisture, kp and kw, respectively, were determined using the Lambert-Beer law of opacity with a nonlinear least-squares regression method. The ...

  • Spatial and temporal variation of water quality of a segment of Marikina River using multivariate statistical methods

    Payatas landfill in Quezon City, Philippines, releases leachate to the Marikina River through a creek. Multivariate statistical techniques were applied to study temporal and spatial variations in water quality of a segment of the Marikina River. The data set included 12 physico-chemical parameters for five monitoring stations over a year. Cluster analysis grouped the monitoring stations into ...


    By IWA Publishing

  • ADMS 5 Buildings Validation Bowline Point Site

    1 Introduction The Bojivline Point1 site is located in the Hudson River valley in New York State (Figure 1). There are two stacks of height 86.9 m, close to the western shore of the river. The emissions from the stacks were buoyant and varied hour by hour, and very close to the stacks there was a complex of buildings. The site itself was rural and the terrain ...

  • Air pollution control using laser analysis – Case Study

    An LDS 6 analyzer monitors HF emissions during the production of hydrofluoric acid in accordance with the German Technical Instructions on Air Quality Control (TA Luft) The customer Fine chemicals and inorganic basic chemicals have been developed and produced at the Seelze chemical site in northern Germany for more than 100 years. Such a basic chemical is ...

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you