surface decontamination Articles

  • Surface Decontamination of Cyanide Compounds

    OBJECTIVE:  Determine the surface decontamination efficacy of DeconGel® 1101 on stainless steel, carbon steel, and concrete surfaces contaminated with potassium ferricyanide using ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) following Environmental Protection ...


    By METIS Scientific

  • Surface Decontamination of Selenium (Se) by DeconGel®

    OBJECTIVE:  Determine the surface decontamination efficacy of DeconGel® 1101 on stainless steel, carbon steel, and concrete surfaces contaminated with Selenium (Se) using ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) following Environmental Protection Agency ...


    By METIS Scientific

  • Surface Decontamination of Asbestos by DeconGel 1101

    Abstract Determine the surface decontamination efficacy of DeconGelTM 1101 on linoleum tile, painted drywall and concrete surfaces contaminated with Asbestos fibers (Chrysotile fibers) was performed with Transmission Electron Microscopy (TEM; ASTM Standard Test Method: D6480- 05) and Polarized Light Microscopy (PLM; EPA approved method for analysis of asbestos from bulk samples). ...


    By METIS Scientific

  • Surface Decontamination of Crude Oil by DeconGel 1101 and 1102

    ABSTRACT Surface decontamination efficacy determination of DeconGelTM 1101 and 1102 on aluminum, stainless steel, and concrete surfaces contaminated with Crude Oil (polyaromatic hydrocarbons fraction) was performed with LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling), 8321B (analysis), and 1654A (Analysis of ...


    By METIS Scientific

  • Surface Decontamination of Organic Bases (Triethylamine) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, aluminum, and concrete surfaces contaminated with Organic Bases (Triethylamine (TEA)) was performed with GC/MS (Gas Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8270C (analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Iodine (Potassium Iodide (KI)) by DeconGel®

    OBJECTIVE: Determine the surface decontamination efficacy of DeconGel® 1101 on stainless steel, carbon steel, floor tile, and concrete surfaces contaminated with potassium iodide (KI) using ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) following ...


    By METIS Scientific

  • Surface Decontamination of Pesticides (DDT) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, carbon steel, and concrete surfaces contaminated with Pesticides (dichlorodiphenyltrichloroethane (DDT)) was performed with LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8321B (analysis). ...


    By METIS Scientific

  • Surface Decontamination of Aldehydes (Glutaraldehyde) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGelTM 1101 on stainless steel, aluminum, and concrete surfaces contaminated with aldehydes (glutaraldehyde) was performed using GC/MS (Gas Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (Sampling) and 8270C (Analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Aromatic Solids (Naphthalene) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGelTM 1101 on stainless steel, aluminum, and concrete surfaces contaminated with aromatic solids (naphthalene) was performed using LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8321B (analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Navy Dye Marker by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on aluminum, stainless steel, and concrete surfaces contaminated with Navy Dye Marker was performed with LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8321B (analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Amine Compounds (Aniline) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGelTM 1101 on stainless steel, aluminum, and concrete surfaces contaminated with amine compounds (aniline) was performed using GC/MS (Gas Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (Sampling) and 8270C (Analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Mercury (elemental) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, porcelain tile, composite tile (unwaxed), linoleum tile, and concrete surfaces contaminated with mercury (elemental) was performed with Mercury Vapor Analysis Sensor (Mercury Tracker 3000) according to Environmental Protection Agency (EPA) SW-846 Method: 7471B: "Mercury in Solid or Semisolid ...


    By METIS Scientific

  • Surface Decontamination of Phenolic Compounds (Catechol) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on aluminum, carbon steel, and concrete surfaces contaminated with Phenolic Compounds (Catechol) was performed with LC/MS (Liquid Chromatography/Mass Spectrometry) in accordance with Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling) and 8321B (analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Motor Oil by DeconGel 1101 and 1102

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 and 1102 on aluminum, stainless steel, and concrete surfaces contaminated with Motor Oil (polyaromatic hydrocarbons fraction) was performed with LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (sampling), 8321B (analysis), and 1654A ...


    By METIS Scientific

  • Surface Decontamination of Alkaloids (Nicotine) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGelTM 1101 on stainless steel, aluminum, and concrete surfaces contaminated with alkaloids (nicotine) was performed using LC/MS (Liquid Chromatography/Mass Spectrometry) according to Environmental Protection Agency (EPA) SW-846 Methods: 3500C (Sampling) and 8321B (Analysis). Hazardous Materials ...


    By METIS Scientific

  • Surface Decontamination of Selenium Compounds (Selenium powder) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, carbon steel, and concrete surfaces contaminated with Selenium powder was performed with ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) according to Environmental Protection Agency (EPA) SW-846 Methods: 3005A (sampling) and 6010C (analysis). Hazardous ...


    By METIS Scientific

  • Surface Decontamination of Iron Compounds (Iron (II) Chloride (FeCl2)) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, carbon steel, aluminum and concrete surfaces contaminated with Iron (II) Chloride (FeCI2) was performed with ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) according to Environmental Protection Agency (EPA) SW-846 Methods: 3005A (sampling) and 6010C (analysis). ...


    By METIS Scientific

  • Surface Decontamination of Iodine Compounds (Potassium Iodide (KI)) by DeconGel 1101

    Abstract Surface decontamination efficacy determination of DeconGel™ 1101 on stainless steel, carbon steel, floor tile, and concrete surfaces contaminated with potassium iodide (Kl) was performed with ICP-OES (Inductively Coupled Plasma-Optical Emission Spectroscopy) according to Environmental Protection Agency (EPA) SW-846 Methods: 3005A (sampling) and 6010C (analysis). ...


    By METIS Scientific

  • Decontamination showers for the pharmaceutical industry

    Removing contamination from Personal Protective Equipment (PPE) is part of the daily routine for many workers in the pharmaceutical industry. They shower when leaving laboratories, production or packing areas to prevent the escape of potentially harmful contaminants. In some instances, they may even shower before entering production areas to avoid contaminating vulnerable processes. Hughes has a ...


    By Hughes Safety Showers

  • Surface Decontamination of PCBs (PCB-laden oil) by DeconGel 1101 and 1102

    Abstract Field testing aboard the USS Missouri maritime museum vessel showed that excellent surface decontamination was achieved by applying DeconGel™ 1102 onto contaminated surfaces, resulting in encapsulation of PCB contaminant by DeconGel's active components. For all contaminated surfaces tested, EPA PCB limit standards (Regulations 761.79, 761.123) of < 10 ug/100 cm2 were ...


    By METIS Scientific

Need help finding the right suppliers? Try XPRT Sourcing. Let the XPRTs do the work for you