suspended solids sensor Articles

  • Using the TurbiTechw² LA and HR Sensors to Measure Suspended Solids

    Continual, accurate Suspended Solids measurement is crucial for monitoring the performance of your aeration and treatment systems, and reacting to changes in water quality and processes quickly. We strive to make our customers’ lives easier, and their systems as efficient as possible, which is why we focus on accuracy and reliability in our two most popular Suspended Solids ...


    By Partech (Electronics) Ltd.

  • How & Why We Measure Suspended Solids

    In case you weren’t sure, Suspended Solids is simply a density measurement used to describe exactly how much waste sludge and particles are in the water, and is measured in milligrams per litre (mg/l), grams per litre (g/l) or percentage solid (%). 1000mg/l = 1g/l = 0.1%. It is used to calculate the amount of material, or load, in a wastewater or industrial system. Suspended Solids ...


    By Partech (Electronics) Ltd.

  • Accuracy of different sensors for the estimation of pollutant concentrations (total suspended solids, total and dissolved chemical oxygen demand) in wastewater and stormwater

    Many field investigations have used continuous sensors (turbidimeters and/or ultraviolet (UV)-visible spectrophotometers) to estimate with a short time step pollutant concentrations in sewer systems. Few, if any, publications compare the performance of various sensors for the same set of samples. Different surrogate sensors (turbidity sensors, UV-visible spectrophotometer, pH meter, conductivity ...


    By IWA Publishing

  • Case Study: Liz Bagshaw on the IRC sensors

    Our infrared IR’C sensors have been making waves in the world of glacial meltwater monitoring. Glacial environments are key indicators of global warming and climate change. They’re also home to a diverse range of microorganisms. Both of these need to be quantified and monitored, but doing this isn’t easy because of the cold, remote environments in which they are found. To combat ...


    By Partech (Electronics) Ltd.

  • Partech Water Instruments Case Study: China’s Success with Partech’s Clever Sensors!

    Ronghuai Water Group uses Partech water instruments in 20 of their water plants across China! Currently, the Watertechw2 pH8000 and TurbiTechw2 LA sensors are used in the plants. The ...


    By Partech (Electronics) Ltd.

  • Partech’s Watertechw2 pH8000 and Turbitechw2 sensors work wonders in China - Case Study

    Built in Britain, recognised worldwide. The most recent Partech plaudits come from Ronghuai water group (Zhejiang province) who are currently using the Watertechw2 pH8000 and Turbitechw2 LA sensors in approximately 20 water plants ...


    By Partech (Electronics) Ltd.

  • How & When We Measure Turbidity

    Turbidity, along with Suspended Solids, is a way of measuring the clarity of a body of water, and how many particles are affecting it. The difference is that while Suspended Solids describes the density of the materials in the water, Turbidity describes how those materials affect light passing ...


    By Partech (Electronics) Ltd.

  • South West Water Exmouth case study

    It can be a tough job for the water treatment industry, faced with the needs to ensure the effectiveness of their treatment plants and processes whilst keeping operating costs within strict budgets. Finding a solution to these challenges means not only investing in the most appropriate technologies so that treatment works fulfil their obligations, but also evaluating ways of optimising ...


    By Partech (Electronics) Ltd.

  • Accuracy and Cost Savings from Automatic Optimization of Dewatering

    Improvements in sensor and automation technology in recent years have made it possible to design a system to control the key variable parameters in and around the dewatering process. By continuously analyzing feed conditions and output from the process, an automated optimization system can make necessary proactive adjustments to the internal settings of the dewatering equipment, the polymer ...

  • On-line measurements provide more accurate estimates of nutrient loading: a case of the Yläneenjoki river basin, southwest Finland

    Automatic on-line measurement stations for water quality components and water level were equipped with dataloggers and GSM transmitters; the stations were installed at two sites in the Yläneenjoki river basin, SW Finland. Measurements during five seasons in 2006–2007 were conducted to find out whether the produced data would provide more accurate estimates of material and nutrient transport than ...


    By IWA Publishing

  • From mess to mass: a methodology for calculating storm event pollutant loads with their uncertainties, from continuous raw data time series

    With the increasing implementation of continuous monitoring of both discharge and water quality in sewer systems, large data bases are now available. In order to manage large amounts of data and calculate various variables and indicators of interest it is necessary to apply automated methods for data processing. This paper deals with the processing of short time step turbidity time series to ...


    By IWA Publishing

  • Reduced order model monitoring and control of a membrane bioreactor system via delayed measurements

    Activated sludge treatment is one of the most widely used processes for wastewater treatment (WWT). These systems are built with sufficient design margin to allow changes in loading and process conditions. This is necessary and prudent to overcome limitations in measurement, monitoring and controlling of WWT process parameters at the desired frequency. Online sensors for mixed liquor suspended ...


    By IWA Publishing

  • Miller Argent case study

    On the hills above Merthyr Tydfil, Miller Argent is undertaking a highly ambitious land reclamation scheme that is also involving the extraction of coal by opencast methods. Known as the 'Ffos-y-fran Land Reclamation Scheme', this is the third and final phase of the East Merthyr Reclamation Scheme which is expected to run for another 17 years. The reclamation works will include the removal of ...


    By Partech (Electronics) Ltd.

  • Turbidity Measurements in Drinking Water, Effluent Discharges and Coagulant Controlling

    This month at Partech Water Instruments we’re talking about our turbidity sensors—fantastic to use as an environmental indicator. So how can they be used? We’re here to tell you about turbidity sensors being utilised for drinking water, effluent discharges and coagulant controlling. Turbidity Sensors and Drinking Water Turbidity sensors ...


    By Partech (Electronics) Ltd.

  • Southern water MLSS case study

    Southern Water has recently installed eight new Partech Turbi-Tech 2000LA systems at its East Worthing water treatment works for measuring Mixed Liquor Suspended Solids (MLSS) in the aeration tanks. This new installation takes Partech’s Turbi-Tech 2000LA and 7200 Series Monitor a step further in becoming the standard instrument for measuring mixed liquor throughout the whole of Southern ...


    By Partech (Electronics) Ltd.

  • Monitoring the variations of the oxygen transfer rate in a full scale membrane bioreactor using daily mass balances

    Oxygen transfer in biological wastewater treatment processes with high sludge concentration, such as membrane bioreactor (MBR), is an important issue. The variation of α-factor versus mixed liquor suspended solids (MLSS) concentration was investigated in a full scale MBR plant under process conditions, using mass balances. Exhaustive data from the Supervisory Control And Data Acquisition (SCADA) ...


    By IWA Publishing

  • Travels with Paul – Quarries and Wastewater Treatment Works

    We followed Paul’s visits in February so we could show you just what a Partech sales engineer does! The month started off in Romsey where Paul carried out a site survey at a very muddy quarry… Paul went to see if Partech could help with their flocculent dosing control. The Partech team are pretty certain they’ll be able to offer an excellent solution, but Paul went to lend a ...


    By Partech (Electronics) Ltd.

  • Wastewater engineers go with the flow

    The efficiency of maintenance work has been improved by water treatment engineers employing Intellisonde monitors in their final effluent. Designed primarily to measure water quality, the Intellisondes also measure flow, and this reading is being used to detect the accumulation of debris that necessitates a maintenance visit. Wastewater treatment efficiency is often measured by the analysis of ...


    By Intellitect Water Ltd

  • Case study – bakery application

    Introduction Clean Water Technology, Inc. is the creator of the Gas Energy System (GEM), the most advanced primary treatment system on the market. The GEM System provides superior reduction of total suspended solids (TSS), biological and chemical oxygen demand (BOD/COD), fats, oils and grease (FOG) and turbidity. Challenge A renowned Bakery and Savory manufacturer in Southern ...


    By Clean Water Technology, Inc.

  • On-Line Nitrate/Nitrite Probes for BNR Process Control

    ABSTRACTReal time nitrogen monitoring plays an increasingly important role for the successful biological nutrient removal at wastewater treatment plants. Though traditionally dissolved oxygen has been the main process control parameter a greater understanding of the biological mechanisms and process conditions like nitrite/nitrate concentrations to achieve lower effluent values becomes necessary, ...